News from LabRulezLCMS Library - Week 48, 2026

LabRulez / AI: News from LabRulezLCMS Library - Week 48, 2026
Our Library never stops expanding. What are the most recent contributions to LabRulezLCMS Library in the week of 23rd November 2026? Check out new documents from the field of liquid phase, especially HPLC and LC/MS techniques!
👉 SEARCH THE LARGEST REPOSITORY OF DOCUMENTS ABOUT LCMS AND RELATED TECHNIQUES
👉 Need info about different analytical techniques? Peek into LabRulezGCMS or LabRulezICPMS libraries.
1. KNAUER: 2D-LC separation of complex phenolic mixture - Part 1: Single Heart-Cut
- Technical note
- Full PDF for download
Chromatographic separation is challenging for highly complex samples containing a large number of compounds as well as for mixtures containing a small number of structurally similar compounds. In both cases, conventional one-dimensional liquid chromatography (1D-LC) often reaches its limits, leading to co-elution and hindering the reliable identification and quantification of individual analytes. Two-dimensional liquid chromatography (2D-LC) improves separation performance by combining two chromatographic separations. Depending on the analytical goal, similar or antagonistic separation modes can be used. In particular, highly orthogonal selectivities enable the separation of compounds that co-elute in the first dimension (1D) in the second dimension (2D), which significantly increases peak capacity and overall separation efficiency.
2D-LC separations can be performed in offline or online modes. In offline 2D-LC, fractions collected from the 1D are stored in intermediate containers and transferred to the 2D later. In contrast, online 2D-LC involves directly or nearly continuously transferring fractions from the 1D to the 2D. Looking at the development of 2D-LC in recent years the focus has increasingly shifted toward online 2D-LC. Additionally, different 2D-LC approaches can address various analytical challenges. The simplest approach is the single heart-cut mode (LC-LC), in which a single fraction is transferred from the 1D to the 2D. This method is ideal for targeted analysis when specific co-eluting compounds in a complex matrix requires further separation. At the opposite extreme, the fully comprehensive mode (LC×LC) fully transfers the 1D into small fractions to the 2D. This provides as much information as possible on the sample. Between these two extremes also hybrid approaches are possible, that combine both modes. Multiple heart-cut 2D-LC (mLC-LC) extends the LC-LC approach by enabling the transfer of multiple selected fractions from the 1D to the 2D. This approach is demonstrated in VTN0056. Selective comprehensive 2D-LC (sLC×LC), on the other hand, focuses on a specific region of the 1D, which is then transferred in small fractions to the 2D. An overview of fraction collection strategies for the four different 2D-LC modes is provided in Fig. 2.
Experimental
- Pump: 2x AZURA® P 6.1 L pump HPG, with 10 ml pump head (SST, degasser and mixer (400 µl)
- Autosampler: AZURA® analytical AS 6.1 L, 862 bar
- Detector: 2x AZURA® MWD 2.1L without flow cell, 190 - 700 nm
- Flow cell: PressureProof Flow cell cartridge with 10 mm path length, 10 μl, 1/16” and 300 bar
- Valve drive: VU 4.1 valve drive for V 4.1 valves
- Valve: AZURA® V 4.1 Valve; 6-Port-2-Pos
- 1D-Column: Eurospher II 100-2 C8 100 x 2 mm
- 2D-Column: Eurospher II 100-3 Phenyl 150 x 3 mm
- Thermostat: AZURA® CT 2.1 Column Thermostat for up to 8 HPLC columns with temperature range between 5-85 °C
Conclusion
Two-dimensional liquid chromatography (2D-LC) was successfully implemented using a single-heart cut (LC-LC) workflow. This workflow separated the first co-eluting EGCG and CA fraction in a complex phenolic mixture within a single analytical run without increasing the overall analysis time. Reversed-phase chromatography was employed in both dimensions with a C8 stationary phase in the 1D and a phenyl stationary phase in the 2D. Identification and quantification of nine out of eleven compounds was achieved. These results demonstrate the suitability of the LC-LC approach for resolving a critical co-elution and improving the quantitative analysis of the complex phenolic mixture investigated in this work. To address the second co-eluting GCG and SA fraction, the mLC-LC approach will be presented in an individual technical note VTN0056.
2. Shimadzu: Trace Analysis Using the High-Sensitivity Cell of SPD-M40 X4 Photodiode Array Detector
- Application note
- Full PDF for download
User benefits
- The high-sensitivity cell of the photodiode array detector SPD-M40 X4 enables highly sensitive detection of trace components. In addition, the detector provides good linearity (up to 3 AU), enabling quantitative analysis over a wide concentration range.
- The low-dispersion injection mode of the autosampler minimizes peak dispersion caused by the system, contributing to enhanced sensitivity for the detection of trace components.
Accurate quantification of trace components requires detection with a high signal-to-noise (S/N) ratio. Increasing the injection volume or sample concentration can be considered as approaches to improve S/N ratio. However, increasing the injection volume may adversely affect peak shape because the sample may not be properly retained at the column inlet due to the influence of the sample solvent. In addition, increasing the sample concentration may result in insufficient solubility of the sample. Therefore, when changes in injection volume or sample concentration are difficult, enhancing detector sensitivity is required for the detection of trace components. In this study, an example of highly sensitive detection of trace components using the photodiode array detector SPD-M40 X4 (high-sensitivity cell) installed in the Nexera X4 system. In addition, the results of an evaluation of detector linearity are shown.
Conclusion
In this study, furosemide, a small-molecule drug, was used as a model sample, and the S/N ratio and linearity were evaluated using the high-sensitivity cell, an optional component of SPDM40 X4. Analysis of a 0.1 mg/L furosemide standard solution showed that the peak detected near the limit of detection with conventional SPD-M40 achieved an S/N ratio more than seven times higher when using the high-sensitivity cell of SPD-M40 X4. In addition, a calibration curve prepared over a concentration range of 0.1–50 mg/L showed good linearity (r² > 0.9999). Furthermore, the use of the low-dispersion injection mode of the autosampler wasshown to further improve the S/N ratio.
3. Thermo Fisher Scientific: Why modernize universal LC detection?
- Other document (White paper)
- Full PDF for download
As pharmaceutical and biopharmaceutical workflows become increasingly complex, analytical laboratories require detection technologies that deliver flexibility, sensitivity, and reliability across a broad range of applications. Detector selection plays a critical role in ensuring accurate, high-quality data, robust analytical methods, regulatory compliance, and efficient laboratory operations. As a result, choosing the appropriate detector is a key consideration for supporting diverse analytical workflows and meeting the evolving demands of modern laboratories.
The most common detector used with high-performance liquid chromatography (HPLC) is the UV/Vis absorbance detector because of its excellent sensitivity, broad linear dynamic range, and compatibility with gradient elution methods. However, UV/Vis detection is inherently selective, as it relies on the presence of a chromophore within the analyte molecule. Consequently, compounds that lack suitable chromophores cannot be detected directly, limiting the applicability of this technique for certain pharmaceutical and biopharmaceutical analytes.
For compounds that lack chromophores, more universal detection techniques are used, including the CAD, the ELSD, mass spectrometry (MS), and the refractive index (RI) detector. RI detection is simple and widely applicable. However, its low sensitivity and incompatibility with gradient elution restrict its use to isocratic separations. MS can provide high sensitivity and specificity, but it may be complex to operate, requires analytes to form gas-phase ions, and often needs isotope-labeled standards for accurate quantitation. ELSDs are among the most widely used universal detectors for liquid chromatography, but they present several well-recognized limitations.
ELSDs typically exhibit a complex and sigmoidal response curve, lower sensitivity, limited linear and dynamic ranges, and analytedependent response variability. In addition, method development requires extensive optimization of multiple operating parameters, while routine maintenance further reduces instrument uptime. The CAD overcomes these limitations by delivering higher sensitivity, improved calibration linearity, broader dynamic range, more consistent analyte response, simplified method development requiring optimization of fewer parameters, and reduced maintenance, resulting in more robust and productive workflows. The CAD is the future of universal detection, supporting modernized workflows, greater efficiency, increased confidence in results, and a detector that is ready for tomorrow’s challenges. To understand these benefits, the following sections examine the underlying CAD technology innovation and the performance across a range of applications compared to ELSD technology.
Conclusion
The CAD provides a more capable universal detection platform for pharmaceutical and biopharmaceutical applications than the ELSD. Across the applications evaluated, the CAD demonstrated advantages that improve both analytical performance and laboratory efficiency via:
- Lower detection limits
- Greater confidence in low-level impurity measurement
- More consistent response across diverse analyte classes
- A broader working range, reducing dilutions and repeated analyses
- Less method optimization and simpler operation
- Lower routine maintenance requirements
These benefits are particularly relevant for complex formulations, including liposomes, lipid nanoparticles, surfactants, and biopharmaceutical excipients. While established ELSD methods may remain fit for purpose, the CAD should be considered the preferred platform for new methods and for workflows being modernized to improve sensitivity, robustness, quantitation, and productivity
4. Waters Corporation: DESI Mass Spectrometry Imaging of Soft Fruit
- Application note
- Full PDF for download
Benefits
- Simple and quick to use
- Maintains mass spectrometer cleanliness
- Removes the requirement for challenging cryosection sample preparation
- Each transfer substrate has its benefits allowing application tailoring
- Identification of different substrates which preserve spatial localization and metabolite content during transfer
Performing an MSI experiment on fruits or vegetables with a high water content can be difficult as the samples may be crushed or splintered during cryo-sectioning, leading to the loss of valuable localization information. Fresh samples may be cut with a knife and placed on the DESI surface as slices; however, this may lead to analytical challenges due to the softness of the tissue causing distortions during analysis, (which can be especially acute for sweet fruit samples) and potential for blockages in the inlet capillary. The mass spectrometer risks contamination from the high sucrose levels which can caramelize on the source surfaces and potentially block the DESI inlet tube. The intense sucrose signals can also lead to competitive ionization and detector saturation, reducing the detection of other analytes of interest.
To resolve these potential problems, it can be preferable to perform a direct transfer method, whereby the fruit or vegetable is cut using a knife and then imprinted onto a suitable substrate. This transfers the analytes from the sample onto the medium and the imprint is then imaged. The method has the benefit of not requiring the sample to be sectioned and also reduces the amount of analytes available for ionization, keeping the mass spectrometer and inlet cleaner.
The three transfer substrates being assessed for this application are glass microscope slides, commercially available nitrocellulose membranes, and Hamamatzu Poropare™ plates.
Experimental
Once transfer has been completed, the imprints of the fruits were allowed to air dry prior to analysis on a Xevo™ MRT P10 Mass Spectrometer coupled to a Waters DESI XS Source. MS imaging was performed in negative ionization mode, with a 50 µm pixel size and used a 95:5 MeOH:H2O spray solvent. The data was processed within Waters High Definition Imaging (HDI™) Software and lockmass correction was performed using the endogenous analyte sucrose at m/z 341.1089.
Conclusion
Utilizing a transfer substrate for metabolite transfer, DESI MS imaging of soft fruit samples was tested with three different substrates: glass microscope slides, nitrocellulose membranes, and Poropare plates from Hamamatzu. All three substrates took imprints of the metabolites from the soft fruit samples and produced ion images that were visualized within the HDI Software. The analyte signals were the strongest from the glass microscope slides; however, the highest level of metabolite delocalization was observed within this substrate. The Poropare plates demonstrated the most optimal preservation of metabolite localization out of all of the substrates compared; however, it also showed the lowest analyte intensity response amongst the substrates tested. The nitrocellulose membrane displayed a moderate loss of spatial localization during the transfer process; however, the substrate showed an improvement in analyte intensity compared to the Poropare membrane. Overall, the DESI XS platform was shown to be well suited for the MS imaging of soft fruit samples using a variety of different direct transfer substrates.