KNAUER AZURA Autosampler AS 6.1LKNAUER AZURA AS 6.1L autosampler with up to 768 samples, ultra-low carryover, and fast injection cycles for HPLC/UHPLC workflows.
Features

KNAUER AZURA Autosampler AS 6.1L

The KNAUER AZURA® AS 6.1L is a high-performance autosampler designed for automated sample injection in HPLC/UHPLC systems, offering high capacity, precision, and flexibility for both routine and high-throughput applications.

The autosampler supports:

  • up to 768 sample positions (microtiter plates)
  • up to 108 standard 1.5 mL vials

A highly effective internal and external needle wash system minimizes carryover to extremely low levels. The system is also fast, with a complete injection cycle taking less than one minute, including needle washing.

Three injection modes are supported:

  • full loop filling (highest precision)
  • partial loop filling (variable volumes)
  • µl pickup (loss-free injection of small volumes)

The integrated ILD™ (Intermediate Loop Decompression) valve ensures accurate high-pressure injections without sample dilution and reduces pressure spikes, protecting the column.

Key Features

  • Autosampler for HPLC/UHPLC systems
  • Up to 768 sample positions
  • Up to 108 vials (1.5 mL)
  • Ultra-low carryover (< 0.0003%)
  • Fast injection cycle (< 1 min)
  • 3 injection modes (full loop, partial loop, µl pickup)
  • ILD™ technology for high-pressure injection
  • PASA™ (pressure-assisted sample aspiration)
  • Optional sample cooling (4–40 °C)
  • Missing vial/plate detection
  • Supports precolumn derivatization

Technical Specifications

Sample Injection

  • Injection volume range: 0.1 µl – 10 mL
  • Precision:
    • Full loop: < 0.3% RSD
    • Partial loop: < 0.5% RSD
    • µl pickup: < 1.0% RSD
  • Accuracy: 0.2 µl (250 µl syringe)

Performance

  • Carryover:
    • < 0.0015% (standard)
    • < 0.0003% (extended wash)
  • Injections per vial: max. 9
  • Cycle time:
    • 7 s (same vial)
    • 14 s (different vials)
    • < 60 s total

Capacity & Compatibility

  • Microtiter plates: ANSI SLAS standard
  • Max vial/plate height: 47 mm

Additional Features

  • Headspace pressure (bubble prevention)
  • Precolumn derivatization
  • Sample tray cooling (optional, 4–40 °C)
  • Vial detection sensor

Materials

  • ETFE, PTFE, stainless steel, glass, Vespel
  • Wide chemical compatibility

Control & Communication

  • LAN / Ethernet
  • Analog inputs
  • TTL inputs (start, stop, freeze)
  • Relay output (alarm, marker)

Operating Conditions

  • Temperature: 10–40 °C
  • Humidity: 20–80%
 

News

News from LabRulezLCMS Library - Week 29, 2026
Article | Poster

News from LabRulezLCMS Library - Week 29, 2026

This week we bring you posters by Agilent Technologies / ASMS, Shimadzu / ASMS, Thermo Fisher Scientific / HPLC and Waters Corporation / HPLC and technical note by KNAUER!
News from LabRulezLCMS Library - Week 25, 2026
Article | Application

News from LabRulezLCMS Library - Week 25, 2026

This week we bring you application notes by Agilent Technologies, Shimadzu and Thermo Fisher Scientific, technical note by KNAUER and brochure by Waters Corporation!