Blind common anabolic steroid screening – ID only
Blind common anabolic steroid screening – ID only
Blind HPLC identification of common anabolic steroids and selected aromatase inhibitors in oils, oral products, and raw API powders. The analysis reports the detected compound without quantification.
Blind common anabolic steroid screening – oils
Blind common anabolic steroid screening – oils
Blind HPLC screening of common anabolic steroids in oil-based samples. The analysis identifies and quantifies all detected target compounds, including mixtures.
DHT enanthate analysis
DHT enanthate analysis
Targeted HPLC analysis of DHT enanthate in oil-based samples and raw API powders. The test confirms compound identity and determines its content in mg/mL or percentage.
Epistane analysis
Epistane analysis
Targeted HPLC analysis of epistane in tablets, capsules, and raw API powders. The test confirms compound identity and determines its content in mg per unit or as a percentage.
Determination of Explosives in Soil and Water Samples (ALS Global)
Determination of Explosives in Soil and Water Samples (ALS Global)
Monitoring, determination, and treatment of environmental contamination by explosives (TNT, RDX, HMX, nitrobenzene, etc.) using HPLC-DAD. ALS performs analyses of 20 target compounds in water and soil.
Identification of the proteins (Bioanalytic)
Identification of the proteins (Bioanalytic)
We perform proteomic analyses on a state-of-the-art high-resolution ZenoTOF 7600 (SCIEX), in which the Zeno ion trap and EAD (Electron-Activated Dissociation) technology together make a powerful combination.
Determination of nitrosamine content (Bioanalytic)
Determination of nitrosamine content (Bioanalytic)
Our offer includes comprehensive development and validation of methods for determination of nitrosamines in pharmaceutical products. We perform the work according to the criteria and needs of the client based on the EMA note.
Analysis of Synthetic Peptide Hormones (Bioanalytic)
Analysis of Synthetic Peptide Hormones (Bioanalytic)
We offer highly specific and sensitive quantitative analysis of peptides by LC-MS/MS technique (LOQ < 1 ng/ml).
Analysis of Anabolic steroids (Bioanalytic)
Analysis of Anabolic steroids (Bioanalytic)
We offer a highly specific and sensitive qualitative analysis of a wide profile of anabolics by LC-HR-MS/MS technique (detection limits range from 0.01 to 5 ng/ml, depending on the substance).
Characteristics of monoclonal antibodies (Bioanalytic)
Characteristics of monoclonal antibodies (Bioanalytic)
At LabExperts, proteomic analyses are performed on a ZenoTOF 7600 high-resolution LC-MS/MS system (SCIEX). For MS/MS analyses, we use Collision induced dissociation (CID) and Electron-Activated Dissociation (EAD) fragmentation.