Our well-established MassLynx software package delivers market-leading versatility and flexibility for all application areas.
MassLynx was first pioneered to simplify interaction with mass spectrometry (MS) and has continually improved to meet changing customer needs. The result: a market-leading software solution that allows users to best leverage their MS system and harness real-time intelligence, ensure MS system performance, and more quickly convert sample data into valuable knowledge. With development largely driven by input from our extensive user base, MassLynx provides the fundamental platform to acquire, analyze, manage, and share mass spectrometry information.
MassLynx Software features a 21 CFR Part 11-compatible security including file encryption, audit log, and secure archival/retrieval technology with flexible security policies to meet your lab requirements. Waters also offers excellent service and support to get the system up and running – for on-time results without the stress.
MassLynx Quantitation Applications
Streamline quantitative data acquisition and processing
The rate determining step in many analyses is not data acquisition, but the speed your data can be converted into useful information.
To assist you with both application-specific data acquisition and the transformation of data into usable results, MassLynx for quantitation offers a range of application managers with specialized data processing functionalities, which eliminates the need for complex time-consuming manual data review, increasing your productivity.
The functionality of MassLynx application managers has been guided by our customers and optimized for your data analysis and processing requirements.
Waters: MassLynx Quantitation Applications.
Overview
- A tried and well-established software package, MassLynx delivers the versatility and flexibility you require for all of your quantitation applications
- MassLynx security system provides compliance ready tools to meet GxP and 21 CFR Part 11 regulations and TargetLynx XS delivers the information necessary for regulatory compliance
- Inlet method editor and MS method editor allow the user to intuitively build LC-MS/MS methods for quantitative data acquisition
- Auto-dwell for MRM dwell times makes it easy to optimize MRM methods to maximize points per peak and get the best quantitative performance
- IntelliStart guarantees maximum system performance and usability for reproducible results
Recommended Use
MassLynx quantitation applications streamline quantitative data acquisition and processing.
MassLynx Mass Detection Applications
Intuitively interact with your mass detection system with MassLynx
The challenges of mass spectrometry (MS) analyses are often compounded by the use of several types of analytical instruments and high personnel turnover. To maintain and even increase laboratory productivity and efficiency, MassLynx Software simplifies interaction with your mass detection system. MassLynx enables users with a wide range of expertise to easily acquire high-quality mass spectral data with minimal training.
MassLynx application managers enable you to focus the power of MS on your laboratory's tasks.
Overview
- MassLynx delivers the versatility and flexibility you require for all of your mass detection applications
- Easy-to-use application managers enable you to simply transform mass spectral data into usable results
- Intuitive setup and interaction with the mass detector guarantees optimal performance and reproducible results
- Routinely using the same intuitive software provides familiarity and simplicity for more efficient workflows
- Inlet method editor and MS method editor allow the user to intuitively build LC-MS methods for qualitative and quantitative data acquisition
Recommended Use
Masslynx Application Managers enable laboratories to confidently produce high quality results without complexity.
Waters: MassLynx Mass Detection Applications.
MassLynx High-Resolution Applications
Fully characterize your samples with Waters high-resolution mass spectrometry
As the power of high-resolution mass spectrometry (HRMS) allows today’s labs to obtain high quality data, the challenge is then to confidently identify and characterize components of interest.
Waters MassLynx Applications enable your lab to efficiently process and interpret HRMS data sets – whether your samples are biological, chemical, environmental, or pharmaceutical, we have a solution that meet your needs, whether it's based on gas chromatography (GC-MS) or liquid chromatography mass spectrometry (LC-MS).
Waters: MassLynx High-Resolution Applications.
Overview
- Rapidly identify metabolites with MetaboLynx XS
- Achieve confident structural elucidation with MassFragment
- Automate the processing of LC-MS, GC-MS, LC-MS/MS, or GC-MS/MS data with ChromaLynx
- Meet quantitative and qualitative proteomics research requirements with ProteinLynx Global Server (PLGS)
Recommended Use
For identifying and characterizing data acquired using high-resolution mass spectrometry.