Deliver accurate quantitative results and spend less time reviewing data in high throughput analytical testing
- Offers the power and flexibility of full-scan high-resolution accurate mass data to quantitative, screening and discovery workflows
- Accelerates data reviewing with multi-point compound identification, including spectral matching, isotope pattern match, retention indices and multiple confirmation ions
Be one step ahead of changing demands
- Provides the flexibility to keep pace with ever-changing regulations and enables you to explore new business opportunities through increased scope and method consolidation
- Offers the option to configure the system with either 30,000 or 60,000 mass resolving power and the ability to add MS/MS capability today or in the future
Focus on results, not instrument setup
- Simple instrument set up and intelligent informatics enable users of all abilities to easily access data-rich information
- Next-generation software, including built-in method templates, provides easy-to-use and flexible options that are fully accessible to all members of the analytical team
Thermo Fisher Scientific: Thermo Scientific Orbitrap™ Exploris™ GC Mass Spectrometer
Benefits that boost productivity
Increase scope
Gain the flexibility to quickly add new compounds without compound optimization and decide post acquisition which analytes to measure.
Fast system setup
Walk up, tune, and calibrate in under five minutes with full confidence that the system is operating at maximum performance for all users.
Efficient review and reporting
Use multiple points of identification to quickly confirm or reject detections, increasing peace of mind. Spectral matching, isotope patterns, retention indices, and elemental compositions provide high confidence in results.
Accurate quantitation
Six orders of linear dynamic range covers the concentrations encountered in even the most complex sample matrices.
Method consolidation
Combine acquisition methods onto a single system, reducing the need for multiple systems and streamlining data processing.
Retrospective analysis
Interrogate previously acquired high-resolution accurate-mass (HRAM) data in multiple ways to answer additional analytical questions without additional sample injections.
Power GC-MS with Thermo Scientific software solutions
- Chromeleon CDS: Enterprise-ready, regulatory-compliant quantitation
- TraceFinder software: High-throughput screening and quantitation
- Compound Discoverer software: Small-molecule unknown identification
Specifications
- Dynamic Range: >5000 within a single Orbitrap mass analyzer spectrum
- Mass Range: 30 to 3000 m/z
- Mass Accuracy: External calibration achieves <3 ppm RMS drift over 24 hours, Internal lock mass calibration achieves <1 ppm RMS drift over 24 hours
- Resolution: Up to 60,000 at m/z 200
- Scan Rates: Up to 40 Hz at resolution setting 7,500 at m/z 200
- Description: Orbitrap Exploris GC Mass Spectrometer, no MS/MS