Consistent, Reliable Results for Simulated Distillation
- Glass Infusion™ technology for higher efficiency and greater column-to-column reproducibility
- Individual QC testing for every column
- Up to 70 % higher efficiency than other columns
- Increased accuracy for high temperature simulated distillation
Want a flexible fused-silica alternative for SimDist testing? See ZB-1HT-Inferno
Recommended Use
- ASTM Methods (D2887, D2887X, D3710, D6352, D7169), Crude Oil, Gasoline Fractions, Petroleum Distillates, Petroleum Fractions, Simulated Distillation, Vacuum Distillates
Upgrade to Zebron from any 100 % dimethylpolysiloxane phase:
Agilent®
- DB®-1
- DB-HT SimDis
- DB-PS1
- DB-PS2887
- CP-SimDist
- CP-SimDist UltiMetal
Restek®
- Rtx®-1
- Rxi®-1HT
- MXT®-1HT SimDist
SGE®
- BP1
- BPX1-SimD
Sharper Peak Shape and Better Efficiency through Uniform Glass Infusion™ Coating Technology
- Sharper Peaks and Higher Efficiency:
- Glass Infusion Technology Provides
- Uniform Coating and Minimizes
- Unwanted Activity.
- Consistency and Reliability:
- Zebron Columns are INDIVIDUALLY
- Tested for Better Reproducibility and
- Overall Performance.
- Higher Efficiency:
- Up to 70 % Higher Column Efficiency.
- Long Lifetime and Better Results:
- Improved Resolution of C50/C52
- Hour after Hour.
- Guaranteed:
- 100 % Risk-Free
Phenomenex: Zebron ZB-1XT SimDist GC Columns
Improved Recovery and Peak Shape
The Benefits of Glass Infusion™ Technology
The Zebron ZB-1XT SimDist metal columns employ a new proprietary bonding called Glass Infusion Technology. The Glass Infusion technology starts by depositing a very uniform layer of glass that completely covers the internal metal surfaces of the column. The result is a uniform coating throughout the column.
Glass Enclosed
- Uniform Glass Infusion ensures adequate covering of exposed metal to promote better recovery and peak shape.
- Each Zebron ZB-1XT is individually tested to confirm and ensure excellent reproducibility.
- The uniform glass coating provides a consistent foundation for stationary phase bonding, thus promoting better over-all efficiency and resolution.
Phenomenex: Glass Enclosed
Exposed Metal
- Non-glass infused with exposed metal can cause tailing peaks and sample adsorption.
- Some manufacturers batch test their columns, leading to poor column-to-column reproducibility.
- These exposed surfaces result in abnormal bonding of the stationary phase which affects chromatographic performance, decreases efficiencies, and inconsistent performance between columns.
Phenomenex: Exposed Metal


