High Temperature Stability for Mid-Polarity
- First non-metal, 35 % phenyl columns stable to 400 ˚C
- Longer lifetime with rugged high temperature, polyimide coated, fused silica tubing
- Robust column for high temperature analysis
- Great for high molecular weight compounds
- Eliminate carry-over with high temperature bake outs
- Low activity, provides good peak shape for acidic and basic samples
Phenomenex: Zebron ZB-35HT Inferno GC Column
Phenomenex: Zebron™ ZB-35HT Inferno™
Recommended Use
Intermediate polarity with high temperature stability (up to 400 °C) for:
- high boilers
- contaminants
- carry-overs
- high-temp bakeouts
Recommended Applications
- Amines
- Aroclors
- Chemicals
- Drugs of Abuse
- EPA Methods 508, 608, 8081, 8141, 8151
- Pesticides
- Pharmaceuticals
- Semi-volatiles
- Steroids
Alternative to: Any 35 % Phenyl 65 % Dimethylpolysiloxane Phase:
- DB®-35ms
- SPB-680
- MDN-35
- DC-35
- Rtx-35
- SPB®-35
- Rtx®-35MS
- 007-11
- EC-35
- BPX35
- AT-35
- HP-35ms
- Sup-Herb
- OV-11
- HP-35
- BPX608
Phenomenex Zebron Inferno GC Columns
Overcome Traditional Obstacles
Challenge # 1: Short Fused Silica Column Lifetimes
Unlike Zebron™ Inferno™ GC columns, traditional fused silica columns are not equipped to handle prolonged exposure to
temperatures above 360 °C. At high temperatures, fused silica GC columns:
- Become inflexible and brittle
- Break easily and cause costly replacement
- Require more system downtime for maintenance
- Can’t separate high molecular weight compounds
Challenge # 2: Cumbersome Metal Column Tubing
Though metal columns have higher temperature limits than capillary columns, they are more difficult to use.
Most metal columns:
- Are inflexible and hard to use
- Require special tubing cutters for installation
- Are prone to leaks from expansion and contraction
- Have active surfaces, giving poor peak shapes for acids and bases
- Are incompatible with MS detectors
How it works
Zebron™ Inferno™ columns offer enhanced performance where other columns fail. The two critical factors that allow for this are:
Advanced ESC™ Bonding Technology
At high temperature ranges, the stability of standard GC columns deteriorates, resulting in increased bleed. Zebron’s Engineered Self Cross-linking™ (ESC) bonding technology reinforces the stationary phase for enhanced column durability and extremely low bleed levels at high temperatures. The result: Inferno columns with the flexibility to perform for high temp oven ramps and bakeouts.
- High Temperature Polyimide Coating
Standard polyimide resin pyrolyzes at temperatures above 360 °C, making the tubing unstable. Zebron Inferno columns use a temperature resistant polyimide resin that shows minimal thermal degradation, even at temperatures up to 430 °C*. This means longer column lifetime at elevated temperatures.
Phenomenex: Zebron Inferno GC Columns - How it works
Features of Zebron Inferno GC Columns
Extremely Low Bleed for Rugged Performance
- Longer column lifetime
- Better reproducibility
- Maximum sensitivity
- More accurate quantitation
Increased Column Lifetime with Enhanced Durability
- Less instrument downtime
- More productivity
- Lower laboratory costs
Standard GC Columns Cannot Withstand High Temperature
After prolonged exposure to temperatures above 360 °C, most traditional GC columns become brittle and inflexible, often spontaneously breaking in the middle of a run. Work is stopped in order to change out the column and perform system maintenance. Unlike these fragile columns, ZebronTM InfernoTM columns have a thermally resistant polyimide coating for longer column lifetime at temperatures up to 430 °C. As a result, you get less instrument downtime, and higher productivity.
Greater Performance for High Boiling Compounds
- Better peak shape
- Improved separation
- More analytes detected
Zebron™ Inferno™ columns have the inertness and temperature stability needed to separate high molecular weight compounds. These high boilers require a thermally rugged column with low bleed levels. Inferno columns provide optimal separation of these analytes.