GPC system is an isocratic HPLC system consisting of one P1 pump, CT1i column thermostat with manual injector and RI1 refractive index detector.
FEATURES
- Optimized pump mechanics of P1 pump with parallel piston design offers excellent flow rate accuracy and low RI signal pulsation.
- The thermal isolated optic with a counter-current heat exchanger and programmable temperature control, results in an extremly stable baseline and an optimal Signal/Noise ratio od RI1.
- The system can be upgraded with autosampler and fraction collector, or VD 400 Viscometer Detector.
- Data acquisition, processing and instrument control is done by Clarity Chromatography Station with GPC option or Agilent TriSEC software.
TECHNICAL SPECIFICATION
- P1 HPLC pump: Flow Rates
- RI1 refractive index detector
- CT1 Column thermostat
- Clarity™ Chromatography Station
COMPONENT SPECIFICATION - P1 HPLC pump: Flow Rates
- Flow Rates: 0.001 to 10.000 mL/min
- Pressure: 0 to 6,000 psi (42 MPa)
- Flow precision: > 0.2% RSD
- Flow accuracy: ± 1 % @ 1mL/min and 7 MPa,
- Pressure accuracy: ± 2% of full-scale, with 80:20 H2O/IPA @ 7 MPa
- Pulsation: ± 0.5 % @ 1mL/min and 7 MPa
- Remote inputs: USB
COMPONENT SPECIFICATION - RI1 refractive index detector
- Light Source: Long-life LED
- Refractive index Range: 1.00 - 1.75 RIU
- Baseline Noise: ± 2.5 nRIU
- Baseline Drift: 200 nRIU/h
- Linearity: > 1000 μRIU
- Flow cell pressure resistance: 5 bar
- Flow cell volume: 15 μl
- Time constant: 0.00/0.01/0.02/0.05/0.1/0.2/0.5/1.0/2.0/5.0/10.0 s
- Analog Output: 1x 0-2.5V
- Outputs: Event 1, Start (OUT), Error (OUT), + 5 V, 24 V Valve
COMPONENT SPECIFICATIONS - CT1 Column thermostat
- Temperature range: 10 °C above ambient temperature to 100 °C
- Temperature accuracy: max. 0,5 % of actual temperature
- Temperature stability: RSD < 0,4 %
- Settability: 0,1 °C
- Internal dimensions: 320 x 50 x 30 mm (L x W x H)
- Compartment material: PTFE coated metal
- Compartment connection: USB
- Control: build-in color touch panel, datasystem
COMPONENT SPECIFICATIONS - Clarity™ Chromatography Station:
Advanced chromatographic datastation for data acquisition and evaluation supported with GPC module for MWD, Mw, Mn, Mz calculation. Enables rutine separations with pre-set methods, containing all experimental and conditions and data evaluation settings. PC Win 10 Professional with LCD monitor included.
Ordering information:
PN/Component:
- SGPC01-001 Streamline™ manual GPC system with Refractive index detector (Includes P1 pump, RI1 detector, CT1i column thermostat with manual injector, solvent rack, Clarity PC station)
Optional configurations:
- ST99-002 Remove CT1i column thermostat with manual injector from system
- SAS90-001 Add AS1 Autosampler to system
- SFC90-001 Add FC1 Fraction collector to system