Toward accurate olefin quantification in plastic waste oils: Analytical strategies and future directions

Scientific articles | 2025 | REFINE LabInstrumentation
GC, GCxGC, HPLC, FTIR Spectroscopy, NMR, Titration, RAMAN Spectroscopy, SFC, GC/MSD
Industries
Energy & Chemicals
Manufacturer

Significance of the topic

Accurate quantification of olefins in plastic-waste–derived oils (pyrolysis oils, hydrothermal liquefaction oils) is critical for their safe storage, downstream upgrading (hydrotreating, steam cracking), regulatory compliance, and valorization into fuels or chemical feedstocks. Plastic-derived oils (POs) typically contain much higher olefin levels than petroleum fractions, which increases oxidation, fouling, catalyst poisoning, and coke formation. Reliable analytical data therefore guide process optimization, upgrading severity, and feedstock blending decisions for chemical recycling and circular-economy applications.

Study objectives and overview

This review critically synthesizes methods (1995–2025) for identification and quantification of olefins in complex plastic-derived oils. It evaluates classical bulk titrations (bromine number, bromine index, iodine value), vibrational and NMR spectroscopy (FTIR, Raman, 1H NMR/HSQC), liquid-phase separations (FIA, HPLC, SFC), traditional and advanced gas chromatography (1D-GC, GC×GC) and selective strategies (Ag+-complexation, derivatization, soft ionization MS, GC–VUV). The authors benchmark method performance, discuss typical interferences from heteroatoms and aromatics, and propose practical multi-technique workflows and priorities for standardization and method validation.

Methodological approaches and analytical scope

  • Titrations: Bromine number (ASTM D1159), Bromine index (ASTM D1492/D2710), and Iodine value (ASTM D5554/EN 14111) provide rapid bulk unsaturation metrics reported as g halogen/100 g. They are simple and low-cost but prone to under- or overestimation due to incomplete reaction with some olefins (e.g., linear α-olefins, sterically hindered olefins, conjugated dienes) and side reactions with heteroatom-containing species (phenols, thiophenes, polyaromatics). Modified IV with Hg(OAc)2 significantly increases reactivity and can approach quantitative determination for polyolefin oils free of interfering heteroatoms.
  • Spectroscopy: FTIR and Raman supply rapid functional-group fingerprints (C=C stretches, =C–H out-of-plane modes) useful for screening and process monitoring but limited for absolute quantification and isomer resolution. 1H NMR (4.0–6.6 ppm olefinic region) measures olefinic hydrogen mol% and, with 2D HSQC, can resolve structural motifs; however, it quantifies hydrogen types (not double bonds per se) and is less sensitive for low-concentration olefins.
  • Liquid chromatography: Fluorescent indicator adsorption (FIA, ASTM D1319) gives group-type vol% (saturates/olefins/aromatics) for ≤315 °C cuts but is slow and classifies dienes ambiguously. Normal-phase HPLC (silica/hexane, RI + UV) and SFC (ASTM D6550) using Ag+-loaded columns enable olefin group quantification across gasoline-to-diesel ranges; SFC offers 1–25 wt% olefin measurement but Ag+ columns are sensitive to sulfur and have limited lifetimes.
  • Gas chromatography: 1D-GC (PONA columns, ASTM D6729/D6733) is robust for naphtha-range fractions and gas analysis (ASTM D2163). Key limitations are co-elution and misassignment for higher-boiling, isomer-rich POs. GC×GC (with FID + qTOF/TOFMS) vastly increases peak capacity and enables near-molecular-level separation and PIONA profiling, though complete olefin/naphthene discrimination still requires selective detection or sample preparation.
  • Selective detection and sample treatment: GC–VUV offers direct functional-group discrimination (olefin vs naphthene vs aromatic) and supports pseudo-absolute quantification without universal calibration; spectral libraries and RRFs require expansion. Soft ionization MS (photoionization, field ionization, chemical ionization, cold-EI) preserves molecular ions and yields diagnostic fragments to determine double-bond positions and branching when combined with GC×GC. Chemical derivatizations (DMDS, ozonolysis, epoxidation, Paterno–Büchi, methoxymercuration, bromination, OsO4 dihydroxylation) enable positional assignment of C=C bonds and improve GC-MS structural elucidation. Ag+-based separations (Ag–SiO2 SPE, argentation LC, Ag-modified SFC or GC phases) selectively retain olefins via π-complexation, providing robust class isolation prior to GC×GC, NMR or MS analyses.

Used instrumentation

  • GC systems: 1D GC with PONA/PDMS columns; long capillaries (50–150 m) for light fractions; refinery gas analyzers with alumina PLOT columns for C1–C6 gaseous olefins.
  • Comprehensive GC×GC: modulated GC×GC with FID, TOF-MS, or qMS detectors; reversed- and normal-phase column sets (e.g., Stabilwax × Rxi-5ms or Mxt-1 × ZB-35HT) and PTV injectors for high-MW cuts.
  • Detectors: FID, EI-MS, GC–VUV (VGA-100/101), PI-TOFMS, FI-TOFMS, CI, cold-EI (promising), high-resolution FT-ICR MS for high-MW/heteroatom species.
  • Chromatography: FIA apparatus, HPLC (normal-phase silica, RI/UV/ELSD), SFC with Ag+-loaded columns (ASTM D6550).
  • Sample prep / selective techniques: Ag–SiO2 SPE cartridges, argentation columns, DMDS reagents, ozonolysis setups, Paterno–Büchi UV reactors, derivatization chemistries, Florisil cleanup for heteroatom removal.
  • Spectroscopy / NMR: FTIR (including QC lasers/photoacoustic cells), Raman with fiber probes, 1H NMR and 2D HSQC; hybrid hyphenations used for library generation and cross-validation.

Main results and discussion

  • Titration-based measures often diverge substantially from molecule-level chromatographic totals. Bromine number frequently underestimates total double bonds in POs (e.g., ~40% lower vs olefin-selective GC×GC) because of incomplete reaction with α-olefins and conjugated dienes and interfering substitution of aromatic/heteroatom species.
  • Modified iodine-value procedures with Hg(OAc)2 catalyst improved completeness of reaction and better matched GC×GC for heteroatom-free polyolefin oils; however, Hg use raises environmental and safety concerns.
  • GC×GC coupled with soft ionization (PI) or GC–VUV provides the most selective, high-resolution approach: GC×GC-FID/TOFMS resolves classes and isomer patterns (e.g., characteristic 3n distributions for PP), while GC–VUV discriminates olefins from naphthenes even when EI mass spectra are ambiguous. Combined workflows (Ag+-SPE pre-fractionation → GC×GC-PI-TOFMS and GC–VUV) produced the best agreement and structural detail in benchmark studies.
  • Derivatization methods (DMDS, ozonolysis, Paterno–Büchi) effectively localize double-bond positions and are complementary to soft ionization MS, but they add labor, toxic reagents (mercury, OsO4), or long reaction times and require careful interpretation for polyunsaturated or highly branched olefins.
  • Ag+-complexation (SPE and chromatographic argentation) is a practical sample-prep and preparative separation tool, especially for heavy PO fractions where direct GC analysis suffers severe co-elution. Ag+-SPE is rapid and robust for isolating olefin-rich fractions prior to GC×GC or NMR.

Benefits and practical applications

  • Combined selective/sample-prep and high-resolution chromatography enables accurate olefin mass balances, better prediction of upgrading severity for hydrotreating, and more reliable steam-cracker feedstock evaluation.
  • Rapid spectroscopic screening (FTIR, Raman) supports process monitoring and quality control, while GC–VUV offers fast group-type quantification when spectral libraries and RRF strategies are in place.
  • Ag+-based fractionation simplifies downstream structural analytics (GC×GC, NMR, PI-MS) and improves quantitation for heavy, heteroatom-laden matrices.

Future trends and opportunities

  • Standardization and method validation: develop interlaboratory-validated protocols combining selective pre-fractionation (Ag+-SPE or derivatization), GC×GC-PI-TOFMS, and orthogonal bulk checks (modified IV) with agreed units (wt%, mmol C=C per 100 g) and ECN/RRF strategies.
  • Expand curated VUV and PI spectral libraries and publish open-access reference datasets (including Ag+-fractionated PO standards) to enable robust deconvolution and PIONA workflows.
  • Further deployment of soft-ionization MS (PI, FI, cold-EI) for routine double-bond position/branching analysis; automation of derivatization (DMDS, PB) and greener reagents to reduce hazards.
  • Machine-learning-assisted chromatographic deconvolution to improve isomer identification and quantitative prediction of detector response variation across olefin subclasses.
  • Assess and mitigate the impact of heteroatom-rich matrices (S, N, O, halogens, metals) on Ag+-based columns and detectors; develop robust cleanup or conditioning workflows to prolong column life and ensure selectivity.

Conclusions

Quantifying olefins in plastic-waste-derived oils requires multi-technique strategies. Bulk titrations remain useful for rapid comparative screening but can be biased by incomplete reactivity and matrix interferences. Spectroscopies provide fast fingerprinting but limited quantitation. The most reliable molecular-level data come from combining selective isolation (Ag+-SPE or controlled derivatization) with high-resolution separation (GC×GC) and selective detection (GC–VUV and soft-ionization MS). Priorities for the field are interlaboratory validation, shared reference materials and spectral libraries, and practical workflows that balance accuracy, throughput, and safety for routine industrial and research applications.

Reference

  • Auersvald, M., Barzallo, G., Gieng, H., Patel, J., Sharma, A., Van Geem, K.M., Straka, P., & Vozka, P. (2025). Toward accurate olefin quantification in plastic waste oils: Analytical strategies and future directions. Trends in Analytical Chemistry, 193, 118463.
  • ASTM D1159-23. Standard Test Method for Bromine Numbers of Petroleum Distillates and Commercial Aliphatic Olefins by Electrometric Titration. ASTM International.
  • ASTM D6550. Standard Test Method for Olefin Content of Gasoline by Supercritical Fluid Chromatography.
  • Dunkle, M.N., Pijcke, P., Winniford, W.L., Ruitenbeek, M., & Bellos, G. (2024). Comparing methods for olefin quantification in pyrolysis oils: GC–VUV vs GC×GC vs bromine number. Journal of Chromatography A, 1713, 464569.
  • Toraman, H.E., Dijkmans, T., Djokic, M.R., Van Geem, K.M., & Marin, G.B. (2014). Detailed compositional characterization of plastic waste pyrolysis oil by GC×GC. Journal of Chromatography A, 1359, 237–246.
  • Zanella, D., Romagnoli, M., Beccaria, M., et al. (2023). The contribution of high-resolution GC separations in plastic recycling research. Analytical and Bioanalytical Chemistry, 415, 2343–2355.
  • Walsh, P., Garbalena, M., & Schug, K.A. (2016). Rapid analysis and time interval deconvolution for fuel group classification using GC–VUV. Analytical Chemistry, 88, 11130–11138.
  • Ni, H., Hsu, C.S., Ma, C., Shi, Q., & Xu, C. (2013). Separation and characterization of olefin/paraffin in coal tar and petroleum coker oil using Ag+ techniques. Energy & Fuels, 27, 5069–5075.

Content was automatically generated from an orignal PDF document using AI and may contain inaccuracies.

Downloadable PDF for viewing
 

Similar PDF

Quantitative determination of olefins in pyrolysis oils from waste plastics and tires using selective adsorption by Ag–SiO2 followed by GC×GC-FID
Advancing circular plastics: hydrotreatment of pyrolysis oils for high-yield ethylene production
COUNTING DOUBLE BONDS: GC×GC–FID FOR PLASTIC PYROLYSIS OILS
A comparative study of aromatic content in pyrolysis oils from waste plastics and tires: Assessing common refinery methods