Importance of the Topic


The accurate quantitation of proteins is essential for understanding biological processes and disease mechanisms.
Data independent acquisition using dia-PASEF on the timsTOF HT platform delivers deep proteome coverage with high reproducibility and reduced missing data.

Study Objectives and Overview


The study aimed to optimize a dia-PASEF acquisition strategy for short LC gradients and assess its performance on single proteome samples and complex mixtures, benchmarking coverage, accuracy and reproducibility.

Methodology and Instrumentation


  • Tryptic digests of yeast, HeLa and E. coli prepared at defined ratios.
  • Separation on a 15 cm C18 column (75 μm ID, 1.6 μm particles, Aurora, IonOpticks) with a 15-minute ACN gradient using nanoElute 2 nano HPLC.
  • Mass spectrometry analysis on timsTOF HT via CaptiveSpray 2 ion source.
  • Window placement optimized with py-diAID; data processed in Spectronaut v18 directDIA+ mode with 1% FDR at peptide and protein levels.

Results and Discussion


  • Yeast proteome: average identification of 4408 protein groups and 50 450 peptides in 15-minute runs with 95% of proteins quantified at CV < 20%.
  • HeLa digest: nearly 8000 protein groups and 105 000 stripped peptides identified, demonstrating scalability to complex human samples.
  • Complex mixture (HeLa/yeast/E. coli): 12 893 protein groups from 173 851 precursors, ~10 peptides per protein, median CV ~5% and accurately recovered theoretical abundance ratios across species.

Benefits and Practical Applications


This optimized dia-PASEF workflow enables high-throughput label-free quantitation with minimal instrument time, making it suitable for large-scale studies such as biomarker discovery, clinical proteomics and systems biology investigations.

Future Trends and Possibilities for Use


Anticipated advancements include integration with AI-driven data analysis, expansion to single-cell proteomics, further reduction of gradient times, and multi-omic workflows that leverage library-free DIA strategies.

Conclusion


The combination of dia-PASEF on the timsTOF HT with short gradients affords near-complete proteome coverage and robust quantitation in under 15 minutes, offering a powerful solution for high-throughput proteomic research.

Content was automatically generated from an orignal PDF document using AI and may contain inaccuracies.

Downloadable PDF for viewing
 

Similar PDF

Assessment of a narrow-window dia-PASEF method for high-throughput proteomics
dia-PASEF® applied on different gradient lengths
Optimizing Selectivity and Ion Utilization for Trapped Ion Mobility Spectrometry for Enhanced DIA Performance
diaPASEF: label-free quantification of highly complex proteomes