News from LabRulezGCMS Library - Week 47, 2026

We, 18.11.2026 | Original article from: LabRulezGCMS Library
This week we bring you application notes by LECO, Shimadzu and Thermo Fisher Scientific!
<p><strong>LabRulez / AI:</strong> News from LabRulezGCMS Library - Week 47, 2026</p>

LabRulez / AI: News from LabRulezGCMS Library - Week 47, 2026

Our Library never stops expanding. What are the most recent contributions to LabRulezGCMS Library in the week of 16th November 2026? Check out new documents from the field of the gas phase, especially GC and GC/MS techniques!

👉 SEARCH THE LARGEST REPOSITORY OF DOCUMENTS ABOUT GCMS AND RELATED TECHNIQUES

👉 Need info about different analytical techniques? Peek into LabRulezLCMS or LabRulezICPMS libraries.

1. LECO: Sensory-Directed Analysis for Beer Aroma Profiling: Stacking Multiple SPME Extractions to Help Connect Olfactory and GC-MS Data

Analytes that are present at very low levels in food, flavor, and fragrance samples can still have a large impact on the overall sample properties. This is particularly true for aroma profiles, as odor thresholds can vary widely for different analytes. Some compounds have low odor thresholds, so their presence can still be impactful even at very low levels. For this reason, sensitive analytical techniques are important to detect and identify these low-level analytes. Gas chromatography with mass spectrometry (GC-MS) analysis with the Pegasus BT offers excellent sensitivity and can uncover many low-level analytes in complex samples. Detection can be further improved by pairing GC-MS with various sample preparation techniques that help concentrate samples for injection, like solid phase micro extraction (SPME) or SPME Arrow. Even with this sensitive set of tools, however, there are still cases where analytes of interest may be below the detection level of the method. One option to improve detection in these cases is to stack multiple SPME extractions to then analyze as a single injection. 

With this sampling approach, a cryotrap is used at the head of the column to collect and hold multiple SPME extractions that have been injected in series. After stacking the specified number of extractions, the cryotrap is rapidly heated to inject, or release, the multiple extractions as a single combined sample. In this application note, this injection procedure is demonstrated for the aroma profiling of a beer sample. In this case, related GC-Olfactory (GC-O) data for the same beer sample was referenced. This olfactory information allowed for a sensory-directed analysis that pointed to chromatographic locations of interest. Some of the olfactory notes pointed to analyte peaks with large S/N, some pointed to analyte peaks with low S/N, and others pointed to a chromatographic region without a notable chromatographic peak in the standard single extraction injection. In some cases, stacking multiple SPME extractions boosted the signal enough that the analyte could be detected and identified. This collection of analytical tools allows for seeing more from your sample of interest and uncovering what may have been missing.

Experimental 

A beer that had previously been analyzed by GC-O was analyzed here with GC-TOFMS. The beer was analyzed with HS-SPME and the sample was incubated at 40 °C for 2 min and extracted for 4 min at the same temperature. A typical single extraction was performed as well as separate injections that stacked multiple SPME extractions (either 2, 3, or 4). A tri-phase SPME fiber (DVB/C-WR/PDMS) was used and the fiber was conditioned for 2 min at 250 °C between injections. GC-TOFMS conditions are listed in Table 1. An alkane standard was also analyzed using the same conditions for retention ® index (RI) calculations. Sample acquisition was automated and controlled with LECO’s ChromaTOF software and GL Science’s Evolution software, and data analysis was performed with ChromaTOF. The previously acquired olfactory data that is referenced was collected with GL Science’s Phaser Pro.

Conclusion

GC-TOFMS is an excellent way to complement olfactory data and connect observed olfactory notes to specific analyte features within complex food, flavor, and fragrance samples. In many cases, clear chromatographic peaks can be associated with the olfactory notes. These are often identified with mass spectral and RI matching and can provide a better understanding of the sensory observations. In some cases, however, an olfactory note may be observed in a chromatographic location without an observable chromatographic peak. This application note highlights an option that can improve detection by stacking multiple SPME extractions to a single injection. This increased the peak height, which allowed for detecting some additional analytes. In this case, stacking injections revealed analytes at chromatographic locations where olfactory notes had previously not been assigned to an observable peak in the single extraction data. Together, these tools provide good options for better understanding the aroma characteristics of these complex samples.

2. Shimadzu: Simultaneous Analysis of Pesticide Residues in Food Using Triple Quadrupole GC-MS/MS with PTV Mode of a Multimode Injection Unit (MMI)

User Benefits
  • The GCMS-TQ 8040 RX and MMI-PTV enable analysis of more than 300 pesticide compounds in complex matrices. 
  • The Smart Pesticides Database automatically creates a multiresidue MRM acquisition method with optimized transitions. 
  • Peakintelligence for GCMS uses AI-based waveform processing for accurate analysis without parameter settings.

Pesticide residue analysis is critical for ensuring food safety. Because the number of target analytes can exceed several hundred, rapid and efficient multiresidue analytical methods are needed. In this study, a simultaneous analytical method for more than 300 pesticide compounds was investigated using the GCMS-TQ 8040 RX triple quadrupole gas chromatographtandem mass spectrometer (Fig. 1). Samples were introduced using a Multi-Mode Injection Unit (MMI) operated in programmed temperature vaporization (PTV) mode. Method development was facilitated by Smart Pesticides Database Ver. 2.2, which includes pre-registered optimized multiple reaction monitoring (MRM) conditions, enabling straightforward transition selection and reducing matrix-derived interferences. In addition, Peakintelligence for GCMS, an AI-based data analysis tool, was used to improve the accuracy and efficiency of peak detection and integration in complex chromatograms. The proposed method was evaluated quantitatively using spinach extracts. The results demonstrated its applicability to comprehensive pesticide residue analysis in food matrices.

Data Analysis with Peakintelligence for GCMS 

Results obtained with Peakintelligence for GCMS were compared with those obtained by conventional peak processing (Chromatopac) (Fig. 10). Conventional processing occasionally resulted in incorrect peak integration, particularly at low concentrations in chromatograms with matrix-derived baseline elevation or adjacent peaks. In contrast, Peakintelligence provided appropriate peak processing for these chromatograms. Its use can reduce the time required for manual correction while enabling reliable quantitative results without operator-dependent variation.

Conclusion 

In this Application News, pesticide residues in spinach extract were analyzed using the GCMS-TQ8040 RX in combination with a Multi-Mode Injection Unit (MMI) and advanced software tools. The GCMS-TQ8040 RX enables reliable detection of trace-level compounds in multiresidue analysis, while the PTV mode of the MMI and appropriate transition selection using the Smart Pesticides Database provide highly sensitive and selective measurements even in complex matrices. In addition, Peakintelligence for GCMS, an AI-based data analysis tool, improves integration accuracy for difficult peaks, streamlines data analysis, and reduces operator-dependent variability. Quantitative evaluation demonstrated excellent trueness and precision even for challenging matrix extracts. These results indicate that this integrated solution is well suited to routine pesticide residue analysis of complex multicomponent samples, helping laboratories improve both confidence in analytical results and operational efficiency.

3. Thermo Fisher Scientific: EPA Method 1613 performance-based dioxin analysis in environmental samples using the Orbitrap Exploris GC S mass spectrometer

Dioxins and furans (polychlorinated dibenzo-p-dioxins and dibenzofurans, PCDD/F) are a class of persistent organic pollutants (POPs) that exhibit extreme toxicity even at picogram-per-gram levels. They are not manufactured for commercial use, but form as unwanted by-products of combustion and certain industrial and thermal processes. Their chemical stability, lipophilicity, and tendency to bioaccumulate have led to strict regulation of PCDD/F under national and international frameworks. Therefore, monitoring programs focus on foodstuffs, environmental matrices, and biota to protect public health. Regulatory test methods require both ultra-trace sensitivity and unambiguous compound confirmation to ensure legally robust reporting and to distinguish true positives from matrix interferences.

EPA Method 16131 was developed to provide a standardized, reproducible approach for the determination of PCDD/F congeners in environmental matrices using isotope dilution quantitation and stringent confirmation criteria. The method is applied to a wide range of sample types encountered in environmental and compliance testing, for example, soils, sludge and sediments, animal tissues (biota), food and feed items, and certain waste and industrial matrices. The combination of low regulatory action levels and the complexity of many matrices drives the need for robust sample preparation and highly selective instrumental analysis, typically using high resolution mass spectrometry.

High-resolution accurate-mass (HRAM) Thermo Scientific™ Orbitrap™ GC-MS combines full-scan or selected ion monitoring (SIM) detection with modern source and maintenance designs that can address many of these challenges. At appropriate resolving power settings, Orbitrap mass analyzers provide narrow mass extraction windows and sub-ppm mass accuracy that improve selectivity against isobaric interferences and increase confidence in congener identification while retaining the quantitative robustness required by isotope dilution procedures. Where full-scan HRAM acquisition is deployed, it also enables retrospective data mining and non-targeted screening alongside targeted regulatory workflows, expanding analytical scope without additional analysis. When integrated with maintenance features that reduce downtime and with software that enables fast implementation, the Orbitrap Exploris GC S mass spectrometer can deliver a practical performance-based alternative for laboratories seeking the combination of sensitivity, selectivity, and operational flexibility needed to meet EPA Method 1613 confirmation criteria across diverse matrices. This study demonstrates those analytical performance elements that are required to meet those criteria.

Experimental

Instrumental method and data processing 

Injection and chromatographic conditions for the Thermo Scientific™ TRACE™ 1610 GC coupled to an Orbitrap Exploris GC S mass spectrometer equipped with a Thermo Scientific™ NeverVent™ Advanced Electron Ionization (NV-AEI) Source are summarized in Appendix Tables A1 and A2. Chromatographic separation was performed using a Thermo Scientific™ TRACE™ TR-Dioxin Capillary Column, 60 m × 0.25 mm i.d. × 0.10 µm film (Cat. No. 26AF059P). Automated liquid injection was accomplished using a Thermo Scientific™ TriPlus™ RSH SMART Autosampler. Data acquisition was performed in timed single ion monitoring (tSIM) at 60,000 resolving power (FWHM at m/z 200), monitoring two exact-mass ions (quantifier and qualifier) for each native and corresponding ¹³C-labeled target to support confirmatory ionratio evaluation consistent with EPA Method 1613 requirements. Additional mass spectrometer and acquisition parameters are summarized in Appendix Figure A1. External mass calibration was performed prior to batch analysis; where applicable, characteristic background/column-bleed ions were used as lock masses for internal mass correction during acquisition. All accurate masses were extracted with a 5 ppm window.

Data were acquired and processed in Thermo Scientific™ Chromeleon™ 7.4 Chromatography Data System (CDS). Confirmation was performed by evaluating: 

  • Presence of the target peak at the expected retention region 
  • Ion ratio agreement between quantifier and qualifier ions using a ±15% relative tolerance (reported as “Confirmed” in sample tables). Data processing and isotopic dilution quantification were performed using the workflow in Chromeleon software.

Conclusion 

The results demonstrate that the Orbitrap Exploris GC S MS delivers performance consistent with the elements of EPA Method 1613 dioxin analysis in environmental matrices.

Performance characteristics relevant to EPA Method 1613 workflows include:

  • Ultra-trace sensitivity: 2,3,7,8-TCDD was reproducibly detected at 15 fg on-column, with replicate injections demonstrating stable signal at the lowest evaluated level. Sensitivity performance and resolving power at this level support the expectations. 
  • High mass resolution exceeding regulatory requirements: Measured resolving power at 5% peak height ranged from approximately 19,000–23,000 across all 17 congeners at both CSL and CS4, exceeding the 10,000 resolving power requirement specified for high-resolution dioxin analysis under EPA Method 1613. This provides enhanced selectivity against near-isobaric interferences.
  • Robust multi-level calibration performance: A 10-level calibration series demonstrated excellent linearity from the 10× diluted low-level standard through CS4, consistent with EPA Method 1613 expectations for multi-point calibration and response stability assessment. 
  • Stable isotope dilution response factors: Response factor summaries across the calibration range showed ≤15% RSD for all 17 congeners, supporting reliable quantitative performance using isotope dilution principles. 
  • Confirmatory ion ratio compliance: Quantifier-to-qualifier ion ratios were evaluated using a ±15% relative tolerance, with automated flagging in Chromeleon CDS. No out-of-tolerance results were observed across calibration or matrix replicate experiments, supporting confirmatory identification criteria.
  • Demonstrated repeatability in environmental matrix: Ten replicate injections of soil spiked at 15 fg on-column showed %RSD values of 3.5%–6.9%, with ion ratio confirmation maintained across replicates, demonstrating stable quantitative and confirmatory performance under matrix conditions.

Collectively, these results show that the Orbitrap Exploris GC S mass spectrometer provides the sensitivity, resolving power, calibration robustness, and confirmation control required for performance-based implementation of EPA Method 1613 dioxin analysis, while additionally offering the operational flexibility and HRAM selectivity advantages inherent to Orbitrap technology

LabRulez
LinkedIn Logo
 

Related articles

News from LabRulezGCMS Library - Week 37, 2024
Article | Application

News from LabRulezGCMS Library - Week 37, 2024

This week we bring to you applications by Agilent Technologies, Shimadzu, and Thermo Fisher Scientific and poster by LECO from ACS meeting!
News from LabRulezGCMS Library - Week 13, 2025
Article | Application

News from LabRulezGCMS Library - Week 13, 2025

This week we bring you application notes by Agilent Technologies, Shimadzu and Thermo Fisher Scientific!
News from LabRulezGCMS Library - Week 27, 2025
Article | Poster

News from LabRulezGCMS Library - Week 27, 2025

This week we bring you other document by Agilent Technologies and posters by Shimadzu / ASMS, Thermo Fisher Scientific / ASMS and Waters / ASMS.
Why a New Orbitrap GC Mass Spectrometer Should Be Considered for Routine Regulatory Analysis
Article | Product

Why a New Orbitrap GC Mass Spectrometer Should Be Considered for Routine Regulatory Analysis

Four application studies demonstrate the capabilities of the Thermo Scientific Orbitrap Exploris GC S for routine pesticide and dioxin analysis using high-resolution accurate-mass GC-MS.
 

Related articles

News from LabRulezGCMS Library - Week 37, 2024
Article | Application

News from LabRulezGCMS Library - Week 37, 2024

This week we bring to you applications by Agilent Technologies, Shimadzu, and Thermo Fisher Scientific and poster by LECO from ACS meeting!
News from LabRulezGCMS Library - Week 13, 2025
Article | Application

News from LabRulezGCMS Library - Week 13, 2025

This week we bring you application notes by Agilent Technologies, Shimadzu and Thermo Fisher Scientific!
News from LabRulezGCMS Library - Week 27, 2025
Article | Poster

News from LabRulezGCMS Library - Week 27, 2025

This week we bring you other document by Agilent Technologies and posters by Shimadzu / ASMS, Thermo Fisher Scientific / ASMS and Waters / ASMS.
Why a New Orbitrap GC Mass Spectrometer Should Be Considered for Routine Regulatory Analysis
Article | Product

Why a New Orbitrap GC Mass Spectrometer Should Be Considered for Routine Regulatory Analysis

Four application studies demonstrate the capabilities of the Thermo Scientific Orbitrap Exploris GC S for routine pesticide and dioxin analysis using high-resolution accurate-mass GC-MS.
 

Related articles

News from LabRulezGCMS Library - Week 37, 2024
Article | Application

News from LabRulezGCMS Library - Week 37, 2024

This week we bring to you applications by Agilent Technologies, Shimadzu, and Thermo Fisher Scientific and poster by LECO from ACS meeting!
News from LabRulezGCMS Library - Week 13, 2025
Article | Application

News from LabRulezGCMS Library - Week 13, 2025

This week we bring you application notes by Agilent Technologies, Shimadzu and Thermo Fisher Scientific!
News from LabRulezGCMS Library - Week 27, 2025
Article | Poster

News from LabRulezGCMS Library - Week 27, 2025

This week we bring you other document by Agilent Technologies and posters by Shimadzu / ASMS, Thermo Fisher Scientific / ASMS and Waters / ASMS.
Why a New Orbitrap GC Mass Spectrometer Should Be Considered for Routine Regulatory Analysis
Article | Product

Why a New Orbitrap GC Mass Spectrometer Should Be Considered for Routine Regulatory Analysis

Four application studies demonstrate the capabilities of the Thermo Scientific Orbitrap Exploris GC S for routine pesticide and dioxin analysis using high-resolution accurate-mass GC-MS.
 

Related articles

News from LabRulezGCMS Library - Week 37, 2024
Article | Application

News from LabRulezGCMS Library - Week 37, 2024

This week we bring to you applications by Agilent Technologies, Shimadzu, and Thermo Fisher Scientific and poster by LECO from ACS meeting!
News from LabRulezGCMS Library - Week 13, 2025
Article | Application

News from LabRulezGCMS Library - Week 13, 2025

This week we bring you application notes by Agilent Technologies, Shimadzu and Thermo Fisher Scientific!
News from LabRulezGCMS Library - Week 27, 2025
Article | Poster

News from LabRulezGCMS Library - Week 27, 2025

This week we bring you other document by Agilent Technologies and posters by Shimadzu / ASMS, Thermo Fisher Scientific / ASMS and Waters / ASMS.
Why a New Orbitrap GC Mass Spectrometer Should Be Considered for Routine Regulatory Analysis
Article | Product

Why a New Orbitrap GC Mass Spectrometer Should Be Considered for Routine Regulatory Analysis

Four application studies demonstrate the capabilities of the Thermo Scientific Orbitrap Exploris GC S for routine pesticide and dioxin analysis using high-resolution accurate-mass GC-MS.