Applications from the field of Pharma & Biopharma focused on LC/IT - page 1

Open paper Characterizing Nucleic Acid Payloads in Lipid Nanoparticles and Viral Vectors via Charge Detection Mass Spectrometry (CDMS)

Characterizing Nucleic Acid Payloads in Lipid Nanoparticles and Viral Vectors via Charge Detection Mass Spectrometry (CDMS)

LC/MS, LC/MS/MS, LC/IT, LC/HRMS
Instrumentation
LC/MS, LC/MS/MS, LC/IT, LC/HRMS
Manufacturer
Waters
Industries
Pharma & Biopharma, Lipidomics
Open paper ANALYTICAL REPEATABILITY AND PRECISION OF THE XEVO CDMS SYSTEM FOR AAV CAPSID CHARACTERIZATION

ANALYTICAL REPEATABILITY AND PRECISION OF THE XEVO CDMS SYSTEM FOR AAV CAPSID CHARACTERIZATION

LC/MS, LC/MS/MS, LC/IT
Instrumentation
LC/MS, LC/MS/MS, LC/IT
Manufacturer
Waters
Industries
Pharma & Biopharma
Open paper SEC-CDMS ENABLES ONLINE BUFFER EXCHANGE AND CHARACTERIZATION OF PROTEIN-BASED THERAPEUTICS

SEC-CDMS ENABLES ONLINE BUFFER EXCHANGE AND CHARACTERIZATION OF PROTEIN-BASED THERAPEUTICS

LC/MS, LC/MS/MS, LC/IT, GPC/SEC
Instrumentation
LC/MS, LC/MS/MS, LC/IT, GPC/SEC
Manufacturer
Waters
Industries
Pharma & Biopharma, Proteomics
Open paper WHAT’S INSIDE A VACCINE? A CLOSER LOOK USING CHARGE DETECTION MASS SPECTROMETRY

WHAT’S INSIDE A VACCINE? A CLOSER LOOK USING CHARGE DETECTION MASS SPECTROMETRY

LC/MS, LC/MS/MS, LC/IT
Instrumentation
LC/MS, LC/MS/MS, LC/IT
Manufacturer
Waters
Industries
Pharma & Biopharma
Open paper Enhancing AAV8 Analysis With Automated ELIT-CDMS Sample Delivery

Enhancing AAV8 Analysis With Automated ELIT-CDMS Sample Delivery

LC/MS, LC/MS/MS, LC/IT
Instrumentation
LC/MS, LC/MS/MS, LC/IT
Manufacturer
Waters
Industries
Pharma & Biopharma
Open paper Streamlined Characterization of Recombinant AAVs via Charge Detection Mass Spectrometry: Insights from the USP AAV8 Reference Standards

Streamlined Characterization of Recombinant AAVs via Charge Detection Mass Spectrometry: Insights from the USP AAV8 Reference Standards

LC/MS, LC/MS/MS, LC/IT, LC/HRMS
Instrumentation
LC/MS, LC/MS/MS, LC/IT, LC/HRMS
Manufacturer
Waters
Industries
Pharma & Biopharma
Open paper Synthetic modified oligonucleotides analysis using a matrix-assisted laser desorption/ionization digital-ion-trap mass spectrometer (MALDI-DIT-MS)

Synthetic modified oligonucleotides analysis using a matrix-assisted laser desorption/ionization digital-ion-trap mass spectrometer (MALDI-DIT-MS)

MALDI, LC/MS, LC/IT
Instrumentation
MALDI, LC/MS, LC/IT
Manufacturer
Shimadzu
Industries
Pharma & Biopharma
Open paper Oligonucleotide Analysis Using the Compact MALDImini™-1 MALDI Digital Ion Trap Mass Spectrometer

Oligonucleotide Analysis Using the Compact MALDImini™-1 MALDI Digital Ion Trap Mass Spectrometer

MALDI, LC/MS, LC/IT
Instrumentation
MALDI, LC/MS, LC/IT
Manufacturer
Shimadzu
Industries
Pharma & Biopharma
Open paper Proton transfer charge reduction (PTCR)

Proton transfer charge reduction (PTCR)

LC/HRMS, LC/MS, LC/MS/MS, LC/Orbitrap, LC/IT
Instrumentation
LC/HRMS, LC/MS, LC/MS/MS, LC/Orbitrap, LC/IT
Manufacturer
Thermo Fisher Scientific
Industries
Pharma & Biopharma
Open paper Analysis of Modification Site of Chemically Modified Antibody Using MALDImini™-1 Compact MALDI Digital Ion Trap Mass Spectrometer

Analysis of Modification Site of Chemically Modified Antibody Using MALDImini™-1 Compact MALDI Digital Ion Trap Mass Spectrometer

MALDI, LC/MS, LC/IT
Instrumentation
MALDI, LC/MS, LC/IT
Manufacturer
Shimadzu
Industries
Pharma & Biopharma