Organomation 6 Position N-EVAP Nitrogen EvaporatorCompact nitrogen evaporator for up to 6 samples with precise flow control, heated bath options, and wide sample compatibility.
Features

Organomation 6 Position N-EVAP Nitrogen Evaporator

The Organomation 6 Position N-EVAP is a compact and cost-effective sample concentrator designed for simultaneous evaporation of up to 6 samples. Based on the proven N-EVAP technology developed in the 1970s, it ensures reliable and reproducible solvent evaporation using nitrogen gas within a heated bath.

The system supports a wide range of sample sizes – 10–30 mm OD as standard, and up to 30–56 mm OD with an optional holder. The circular rotating design allows easy front access to all samples.

Key Features

  • Evaporation of up to 6 samples simultaneously
  • Adjustable nitrogen flow: 0–10 L/min
  • Individually adjustable needle valves for precise control
  • Circular rotating sample holder for easy access
  • Wide sample diameter range: 10–56 mm OD (with optional holder)
  • Stainless steel bath construction for durability
  • Water or dry bath configurations available
  • High temperature limit switch for safety
  • Phthalate-free silicone tubing to prevent contamination
  • Efficient nitrogen usage with minimal waste

Technical Specifications

General

  • Number of positions: 6
  • Sample holder layout: Circular
  • Gas manifold: Single ring
  • Gas flow meter: 0–10 L/min
  • Standard sample OD: 10–30 mm
  • Optional sample OD: 30–56 mm
  • Gas input pressure: 20–30 psig
  • With regulator: 30–160 psig

Dimensions

  • Water bath: 33 × 28 × 79 cm
  • Dry bath: 33 × 28 × 70 cm
  • Reduced height: 33 × 28 × 61 cm

Needles

  • Length: 4 in (≈10 cm)
  • Gauge: 19 ga
  • Material: stainless steel + chrome-plated brass hub

Heating – Water Bath

  • Temperature range: 30–90 °C
  • Power: 550 W
  • Controller: mechanical thermostat
  • Accuracy: ±2 °C

Heating – Dry Bath

  • Temperature range: 40–130 °C
  • Power: 500 W
  • Medium: aluminum / glass beads
  • Accuracy: ±2 °C
 

News

The Continued Rise of Tandem Chromatography–Mass Spectrometry
Article | Academy

The Continued Rise of Tandem Chromatography–Mass Spectrometry

Discover why LC–MS/MS and GC–MS/MS continue to expand across regulated laboratories, driven by biopharma, PFAS regulations, AI-powered workflows, and advances in sample preparation.
Micro-Snyder Column vs Nitrogen Blowdown: Choosing the Right Concentration Method for EPA Applications
Article | Academy

Micro-Snyder Column vs Nitrogen Blowdown: Choosing the Right Concentration Method for EPA Applications

Micro-Snyder column or nitrogen blowdown? Explore the advantages, limitations, and EPA applications of two widely used concentration techniques for environmental and trace analysis.