The Organomation 6 Position N-EVAP is a compact and cost-effective sample concentrator designed for simultaneous evaporation of up to 6 samples. Based on the proven N-EVAP technology developed in the 1970s, it ensures reliable and reproducible solvent evaporation using nitrogen gas within a heated bath.

The system supports a wide range of sample sizes10–30 mm OD as standard, and up to 30–56 mm OD with an optional holder. The circular rotating design allows easy front access to all samples.

Key Features

  • Evaporation of up to 6 samples simultaneously
  • Adjustable nitrogen flow: 0–10 L/min
  • Individually adjustable needle valves for precise control
  • Circular rotating sample holder for easy access
  • Wide sample diameter range: 10–56 mm OD (with optional holder)
  • Stainless steel bath construction for durability
  • Water or dry bath configurations available
  • High temperature limit switch for safety
  • Phthalate-free silicone tubing to prevent contamination
  • Efficient nitrogen usage with minimal waste

Technical Specifications

General

  • Number of positions: 6
  • Sample holder layout: Circular
  • Gas manifold: Single ring
  • Gas flow meter: 0–10 L/min
  • Standard sample OD: 10–30 mm
  • Optional sample OD: 30–56 mm
  • Gas input pressure: 20–30 psig
  • With regulator: 30–160 psig

Dimensions

  • Water bath: 33 × 28 × 79 cm
  • Dry bath: 33 × 28 × 70 cm
  • Reduced height: 33 × 28 × 61 cm

Needles

  • Length: 4 in (≈10 cm)
  • Gauge: 19 ga
  • Material: stainless steel + chrome-plated brass hub

Heating – Water Bath

  • Temperature range: 30–90 °C
  • Power: 550 W
  • Controller: mechanical thermostat
  • Accuracy: ±2 °C

Heating – Dry Bath

  • Temperature range: 40–130 °C
  • Power: 500 W
  • Medium: aluminum / glass beads
  • Accuracy: ±2 °C
 

News

The Continued Rise of Tandem Chromatography–Mass Spectrometry
Article | Academy

The Continued Rise of Tandem Chromatography–Mass Spectrometry

Discover why LC–MS/MS and GC–MS/MS continue to expand across regulated laboratories, driven by biopharma, PFAS regulations, AI-powered workflows, and advances in sample preparation.
Micro-Snyder Column vs Nitrogen Blowdown: Choosing the Right Concentration Method for EPA Applications
Article | Academy

Micro-Snyder Column vs Nitrogen Blowdown: Choosing the Right Concentration Method for EPA Applications

Micro-Snyder column or nitrogen blowdown? Explore the advantages, limitations, and EPA applications of two widely used concentration techniques for environmental and trace analysis.