Pharmacokinetic study based on atmospheric pressure MALDI-IT-TOF imaging mass microscope: A case of octreotide in mouse target tissues

Posters | 2016 | ShimadzuInstrumentation
MALDI, MS Imaging, LC/TOF, LC/MS, LC/MS/MS, LC/IT
Industries
Clinical Research
Manufacturer
Shimadzu

Significance of the Topic


Imaging mass spectrometry provides spatially resolved detection of drug molecules within tissues, offering critical insight into absorption, distribution, and elimination processes. Applying this approach to octreotide, a long‐acting somatostatin analogue, enhances our understanding of its in vivo behavior and supports optimization of therapeutic regimens.

Objectives and Study Overview


This work aimed to validate and apply the iMScope TRIO atmospheric pressure MALDI‐IT‐TOF imaging mass microscope for quantitative pharmacokinetic analysis of octreotide in mouse stomach and intestinal tissues following oral dosing. A novel relative exposure strategy using lanreotide as an internal standard enabled pixel‐by‐pixel quantification while preserving spatial information.

Methodology and Instrumentation


  • Animal dosing: Mice received 50 mg/kg octreotide orally; tissues were collected at 10, 20, 40, 60, 120, 240, and 360 minutes postdose.
  • Sample preparation: 10 µm thick stomach and intestinal sections; α‐CHCA matrix applied by sublimation and airbrushing to maximize ionization efficiency.
  • Imaging analysis: iMScope TRIO system combining optical microscopy, AP‐MALDI ion source, and hybrid quadrupole ion trap TOF; 5 µm spatial resolution; Nd:YAG 355 nm laser (500 Hz, intensity 25, pulse width 5 ns, 50 shots per pixel).
  • Calibration and quantification: Calibration curves constructed in drug‐free stomach sections spiked with known octreotide levels (1–20 pmol) normalized to 10 pmol lanreotide; method precision assessed across multiple tissue replicates.
  • Comparative validation: Homogenized gastrointestinal samples analyzed by conventional LC‐MS/MS (Shimadzu LCMS-8050) for absolute quantification and method benchmarking.

Main Results and Discussion


  • Matrix selection: α‐CHCA outperformed DHB and SA for octreotide signal intensity.
  • Quantitative performance: Linear response observed over 1–20 pmol range; consistent precision across sections.
  • Gastric pharmacokinetics: Tmax at 10 minutes, half‐life 28.0 minutes; imaging revealed transport from mucosal layer to muscle.
  • Intestinal pharmacokinetics: Tmax at 40 minutes, half‐life 37.7 minutes; rapid elimination evidenced by declining signal.
  • Method validation: Imaging‐based quantification correlated well with LC‐MS/MS data, confirming reliability for pharmacokinetic assessment.

Benefits and Practical Applications


This imaging methodology enables direct visualization of drug localization and dynamic concentration changes without tissue homogenization, simplifying sample preparation and reducing loss of spatial context. It supports drug development by elucidating absorption pathways and target tissue exposure.

Future Trends and Potential Applications


  • High‐throughput imaging workflows for multiplexed drug studies.
  • Advanced computational approaches for absolute concentration mapping in tissues.
  • Extension to large biomolecules, peptide therapeutics, and nanoparticle tracking.
  • Integration with histological staining for correlated multimodal analysis.

Conclusions


The iMScope TRIO imaging mass microscope effectively quantified and visualized octreotide distribution in mouse gastrointestinal tissues, yielding pharmacokinetic parameters in agreement with LC‐MS/MS. This technique offers a practical, spatially resolved tool for in vivo drug distribution and pharmacokinetic studies.

Used Instrumentation


  • iMScope TRIO imaging mass microscope (Shimadzu)
  • Atmospheric pressure MALDI ion source
  • Nd:YAG 355 nm diode‐pumped laser
  • Quadrupole ion trap time‐of‐flight analyzer
  • iMLayer matrix sublimation system
  • Shimadzu LCMS-8050 for LC-MS/MS validation

Reference


Shimadzu Corporation. Pharmacokinetic study based on atmospheric pressure MALDI‐IT‐TOF imaging mass microscope: A case of octreotide in mouse target tissues. ASMS 2017 ThP 287.

Content was automatically generated from an orignal PDF document using AI and may contain inaccuracies.

Downloadable PDF for viewing
 

Similar PDF

Analysis of Standard Sample by Drug Imaging
Analysis of Standard Sample by Drug Imaging
2017|Shimadzu|Technical notes
Complementary bioimaging of Gadofluorine P in myocardial infarction in mic
Rapid Mapping of Imipramine, Chloroquine, and Their Metabolites in Mouse Kidneys and Brains Using the iMScope QT
Analysis of Lipids in a NAFLD Model Mouse