MarqMetrix All-In-One Process Raman Analyzer

Brochures and specifications | 2025 | Thermo Fisher ScientificInstrumentation
RAMAN Spectroscopy
Industries
Manufacturer
Thermo Fisher Scientific

Significance of the topic


Real-time, nondestructive process analytical technologies are critical for modern manufacturing, bioprocessing, and quality control. Raman spectroscopy provides molecularly specific information without sample preparation and can be deployed inline or at-line to accelerate decision making, reduce waste, and protect valuable samples. Portable, factory-calibrated Raman systems that are simple to operate lower the barrier to adoption in regulated and time-sensitive environments, enabling broader use of vibrational spectroscopy for process monitoring and control.

Objectives and overview of the document


This document presents an overview of the Thermo Scientific MarqMetrix All‑In‑One Process Raman Analyzer: its intended use, operational advantages, technical specifications, optional accessories, safety and electrical characteristics, and ordering information. The goal is to summarize the analyzer’s capabilities for rapid deployment in process-monitoring scenarios where ease of use, portability, and reproducible results are essential.

Methodology and operating concept


The MarqMetrix analyzer is a compact Raman spectrometer designed for out-of-the-box, one-button operation. It acquires Raman spectra in real time without requiring sample preparation, using a fiber-coupled probe (BallProbe) for noninvasive or single-use sampling. Factory calibration and a stabilized detector architecture aim to ensure hardware stability and repeatable performance across locations. Software packaged with the instrument provides onboard data handling on an integrated Windows PC, facilitating quick start-up and straightforward integration into existing process workflows.

Used instrumentation


  • Excitation source: 785 nm laser, adjustable power 100–450 mW.
  • Detector: thermally stabilized CCD with two-stage thermoelectric cooling (2-stage TEC).
  • Spectral performance: 100–3,250 cm–1 spectral range with an average resolution of ~6.5 cm–1 across the range; RMS dark noise ≤16.5 counts at 10 s integration.
  • Sampling optics: Fiber-coupled (FC/PC) connections with Fiber BallProbe™ sampling optic; multiple interchangeable FiberHeads and BallProbe variants available (process, bioreactor, high‑throughput, proximal, and single-use options, plus low-/med-pressure flow cells).
  • Mechanical footprint: compact enclosure (approx. H 7.7 cm × W 25 cm × D 25 cm), stackable mounting options, designed for portability and field deployment in a protective case.
  • Environmental limits: recommended operating temperature 15°C–30°C, noncondensing humidity.
  • Onboard computing and I/O: integrated PC (Windows 10), MarqMetrix Raman Suite software, Ethernet (RJ‑45), USB 3.0, DisplayPort (VGA/DVI/HDMI via adapter), wireless mouse and HDMI monitor included.
  • Electrical: universal AC input 90–264 VAC, 50–60 Hz; onboard 12 VDC, 2 A operating voltage.

Key performance features


  • Rapid, nondestructive spectral acquisition enabling real-time results and decisions without consumable sample preparation.
  • Factory calibration for consistent, portable performance and reduced need for on-site spectroscopic expertise.
  • Wide spectral coverage suitable for identification and quantification of organic and many inorganic process analytes in the 100–3,250 cm–1 window.
  • Sufficient spectral resolution (~6.5 cm–1) for resolving common Raman bands used in chemical/process analyses.
  • Low detector noise for improved signal-to-noise at practical integration times.

Main results and discussion


While this document is a product overview rather than an experimental study, the provided specifications indicate the MarqMetrix All‑In‑One analyzer is engineered for rapid deployment in process environments. The combination of 785 nm excitation and a cooled CCD detector is a well-established configuration balancing fluorescence suppression and sensitivity for many process chemistries. Factory calibration and modular FiberHead options increase versatility: users can select probes and flow cells matched to bioreactors, process piping, or single-use systems. The compact size and included peripherals support portable, at-line measurements in under 15 minutes from setup, improving time-to-result compared with typical laboratory workflows.

Practical considerations include the specified operating temperature range (15–30°C) and the Class 3B laser safety requirements (interlocks and electronic trigger), which necessitate appropriate administrative and engineering controls in deployment areas. Integration into automated process lines will depend on software connectivity and customization using the supplied MarqMetrix Raman Suite and available I/O ports.

Benefits and practical applications


  • Process monitoring and control: inline or at-line identification and quantification of reactants, products, and impurities for chemical manufacturing and bioprocessing.
  • Quality assurance and batch release: rapid verification of material identity and consistency without consumables or destructive sampling.
  • Research and development: fast molecular fingerprinting for formulation screening and reaction optimization.
  • Field and point-of-need analytics: portable design and factory calibration enable deployment at different sites with reproducible results.
  • Reduced reliance on specialized spectroscopy personnel due to simplified hardware and software workflows.

Practical limitations and considerations


  • Environmental constraints: performance optimized within the specified temperature/humidity envelope; extreme environments may require additional controls.
  • Laser safety: Class 3B laser demands controlled access, interlocks, and trained operators for safe use.
  • Optical coupling and sampling: appropriate selection of FiberHead/BallProbe is necessary to match sample geometry and optical throughput; flow cell seals (gold or Kalrez) are available for pressure-rated applications.
  • Regulatory context: brochure notes Research Use Only and not for diagnostic procedures; regulatory validation is required for GMP or clinical applications.

Future trends and potential applications


  • Tighter process integration: expanded digital interfaces and real-time control loops will allow Raman analytics to feed automated process adjustments directly (PAT/continuous manufacturing).
  • Cloud-enabled analytics and AI: cloud-based models and machine learning can augment onboard chemometric models for adaptive calibration and anomaly detection across multiple sites.
  • Expanded single-use and sterile sampling: development of more single-use probe options and sterile interfaces will broaden adoption in biomanufacturing and cell-culture monitoring.
  • Miniaturization and multimodal sensing: combining Raman with other compact spectroscopies (e.g., NIR, fluorescence) or sensors (pH, DO) in a single portable package could provide richer process information.
  • Regulatory acceptance and validation toolkits: standardized validation workflows and software that support 21 CFR Part 11 compliance will accelerate use in regulated manufacturing environments.

Conclusion


The MarqMetrix All‑In‑One Process Raman Analyzer is positioned as a portable, user-friendly Raman spectroscopy platform tailored for rapid process monitoring and at-line analysis. Its core strengths are factory calibration, modular sampling optics, cooled detector performance, and a compact form factor that supports quick setup and reproducible results without extensive spectroscopy training. For organizations aiming to implement vibrational spectroscopy in process analytical technology (PAT) workflows, this instrument offers a pragmatic balance of performance, portability, and usability, with modular accessories to match diverse sampling needs.

Reference


Thermo Fisher Scientific. MarqMetrix All‑In‑One Process Raman Analyzer product datasheet and ordering information. 2025. (Product brochure).

Content was automatically generated from an orignal PDF document using AI and may contain inaccuracies.

Downloadable PDF for viewing
 

Similar PDF

MarqMetrix All-In-One Process Raman Analyzers
MarqMetrix All-In-One Process Raman Analyzers
2026|Thermo Fisher Scientific|Presentations
MarqMetrix All-In-One X Process Raman Analyzer
MarqMetrix All-In-One X Process Raman Analyzer
2025|Thermo Fisher Scientific|Brochures and specifications
Process Raman Spectroscopy for carbon capture applications
Process Raman Spectroscopy for carbon capture applications
2023|Thermo Fisher Scientific|Brochures and specifications
Enhancing Monoclonal Antibody Yield and Quality Through Automated Multi-Component Feedback Control Loops Using the MarqMetrix All-In-One Process Raman Analyzer