MarqMetrix All-In-One Process Raman Analyzers

Presentations | 2026 | Thermo Fisher ScientificInstrumentation
RAMAN Spectroscopy
Industries
Manufacturer
Thermo Fisher Scientific

MarqMetrix All‑In‑One Process Raman Analyzers — Technical Summary


Importance of the topic
The increasing complexity of continuous manufacturing and strict regulatory demands require reliable, real‑time analytical insight directly in the process stream. Raman process analyzers that operate in-line or at-line enable immediate compositional monitoring, closed‑loop control and rapid troubleshooting without consumables. Solutions that combine safety certifications for hazardous locations, low maintenance, modular scalability and integrated chemometric software are particularly valuable across pharmaceuticals, biopharma, petrochemicals, polymers and food & beverage manufacturing.

Objectives and overview of the document
This technical introduction presents the Thermo Scientific MarqMetrix All‑In‑One and All‑In‑One X Process Raman Analyzers, describing their design principles, modular multiplexing architecture, application domains, software ecosystem, instrumentation choices, key performance specifications and parts/accessories. The brochure aims to explain how the product delivers continuous, multi‑point Raman measurements for process analytics and to summarize practical deployment options and benefits for industrial users.

Methodology and operational concept
  • Modular multiplexing: distributed network of compact analyzers that acquire spectra from multiple points in true real time (simultaneous collection), removing the sequential scan delays of traditional multiplexing.
  • In‑line and proximal sampling: supports immersion probes (BallProbes), flow cells (removable and fixed), single‑use optics and non‑contact proximal probes suited to a wide range of process geometries and sterility requirements.
  • Chemometrics and PAT integration: local instrument or server‑hosted model execution using PLS, PCA and PLS‑DA models; support for model file formats (.xml, .mat); integration with process control via OPC‑UA, Modbus and other industrial protocols.
  • Maintenance and calibration: factory‑set, hardware‑calibrated optics with no routine calibration required; designed for minimal maintenance and quick swap‑in servicing to maximize uptime.

Used instrumentation
  • Excitation: 785 nm laser (Class 3B). Standard All‑In‑One instrument supports up to 450 mW; All‑In‑One X limited to 35 mW for ATEX Zone 0 compliance.
  • Detector: thermally stabilized CCD with two‑stage TEC cooling.
  • Spectral performance: 100–3250 cm−1 spectral range; average spectral resolution ~6.5 cm−1; dark noise ≤16.5 counts (10 s integration).
  • Sampling optics: broad portfolio including single‑use and autoclavable BioReactor BallProbes, threaded and flanged BallProbes, proximal non‑contact probes (working distances 8 mm to 100 mm), FlowCell variants (low, medium, high pressure and removable), and single‑use flow cells for sterile applications.
  • Materials and ratings: probe wetted materials range from SS316L, Hastelloy C276, Inconel 625 to Hastelloy/Gold coatings; temperature ratings from cryogenic up to 350 °C depending on probe; pressure ratings from 50 psi single‑use up to 9000 psi for high‑pressure FlowCell.
  • Connectivity and hardware: integrated Windows‑based controller, Ethernet and multiple USB ports, fiber jumper assemblies (5–100 m) with FC/FC connectors, FC/PC fiber conditions for excitation and collection.
  • Software: Lykos PAT (21 CFR Part 11 capable), Runspex and Spexware for R&D and manufacturing workflows; model building/export via Eigenvector Solo tools.

Main results and discussion (performance highlights)
  • Real‑time simultaneous multi‑point acquisition produces true real‑time process insight rather than near‑time aggregated scans.
  • Compared to traditional multiplexing the modular approach claims up to 24× faster aggregate scan throughput and up to ~3× higher signal‑to‑noise ratio for some configurations, while preserving comparable spectral resolution.
  • Operational economics: lower CapEx (reported 30–40% reduction) and OpEx (40–50% reduction) through elimination of consumables, reduced lab transfers, minimal maintenance and decentralized scaling.
  • Reliability and safety: modular architecture reduces single‑point failures, supports swap‑in servicing, and the X variant is certified for hazardous environments (ATEX, IECEx, NEC Class I Division 1 / Zone 0 options).
  • Application breadth: demonstrated suitability for upstream/downstream biopharma (nutrients, metabolites, cell growth, viral vectors, nucleic acid therapies), pharma QC (blend and dissolution monitoring, polymorph analysis), oil & gas (blend certification, aromatics/olefins monitoring), polymers and reactive extrusion monitoring.

Key practical considerations for deployment
  • Sampling optic selection must match application constraints: immersion vs non‑contact, sterilization (autoclavable vs single‑use), pressure/temperature ratings and connection types (flanged, threaded, tri‑clamp, Swagelok).
  • Fiber jumpering permits flexible placement but core diameters and fiber lengths can influence light throughput and SNR; fiber assemblies available up to 100 m with armored jackets.
  • Hazardous area deployments require the X variant (reduced laser energy) and appropriate certified probe and electrical interfaces.
  • Chemometric model transferability is facilitated by factory wavelength calibration and comparable spectral resolution across instruments, easing global method replication.

Benefits and practical uses
  • Immediate process control: inline compositional data for feedback loops and automated control strategies (e.g., UF/DF control, blend optimization, reaction endpoints).
  • Quality assurance: real‑time identification of out‑of‑spec events, polymorph or blend uniformity issues, and dissolution/solid‑dose monitoring without offline sampling delays.
  • Cost and productivity: elimination of consumables and regular carrier gases, reduced sample handling, and lower service needs lead to lower total cost of ownership.
  • Scalability and method portability: modular hardware and standardized model formats simplify multi‑site rollouts and scale‑up from R&D to manufacturing.

Parts, accessories and service overview
  • Extensive parts catalog covers base instruments, probe families (Bioreactor, Performance, Process, Threaded, FlowCell, Single‑use), fiber jumper assemblies, adapters and spare parts (o‑rings, interlocks, mating sleeves).
  • Flow cells available in multiple volumes (100 µL to several mL) and pressure classes for loop or bypass implementations; removable flow cells enable easy cleaning and replacement.
  • Service plans include depot repair, maintenance for compliance, consulting and chemometric support; global technical support contacts are provided for regional service.

Future trends and possibilities of use
  • Tighter integration with advanced PAT ecosystems: edge computing for on‑instrument model scoring, cloud‑assisted model governance, and digital‑twin process simulations.
  • AI‑driven chemometrics: wider adoption of machine learning models for complex matrix deconvolution, anomaly detection and predictive maintenance of instruments.
  • Broader single‑use adoption in bioprocessing: growth of sterile single‑use probe and flow cell formats to support disposable manufacturing lines and rapid changeover.
  • Expanded hazardous‑area Raman: increased deployment in upstream/midstream oil & gas, refining and petrochemical plants using intrinsically safe, certified analyzers for continuous monitoring.
  • Hybrid sensor networks: combination of Raman with orthogonal at‑line sensors (NIR, UV‑Vis, conductivity) to enrich process models and support multi‑parametric control strategies.

Conclusion
The MarqMetrix All‑In‑One family positions a Raman‑first approach to process analytics by combining modular, multi‑point real‑time acquisition with robust sampling optics, factory calibration and integrated PAT software. Its design targets reduced operating costs, scalable deployments and compliance needs while maintaining high chemical specificity and acceptable spectral performance. For manufacturers seeking inline compositional control, the product provides a practical route to faster decision making, improved product quality and lower total cost of ownership.

References
  • Thermo Fisher Scientific. MarqMetrix All‑In‑One Process Raman Analyzer — Technical Introduction and Specifications. Thermo Fisher Scientific Technical Brief, 2026.

Content was automatically generated from an orignal PDF document using AI and may contain inaccuracies.

Downloadable PDF for viewing
 

Similar PDF

MarqMetrix All-In-One Process Raman Analyzer
MarqMetrix All-In-One Process Raman Analyzer
2025|Thermo Fisher Scientific|Brochures and specifications
MarqMetrix All-In-One X Process Raman Analyzer
MarqMetrix All-In-One X Process Raman Analyzer
2025|Thermo Fisher Scientific|Brochures and specifications
Process Raman Spectroscopy for carbon capture applications
Process Raman Spectroscopy for carbon capture applications
2023|Thermo Fisher Scientific|Brochures and specifications
Enhancing Monoclonal Antibody Yield and Quality Through Automated Multi-Component Feedback Control Loops Using the MarqMetrix All-In-One Process Raman Analyzer