Analysis of Monosaccharides and a Disaccharide

Applications | 2026 | ShimadzuInstrumentation
Consumables, LC columns, HPLC
Industries
Manufacturer
Shimadzu

Significance of the topic


Hydrophilic interaction liquid chromatography (HILIC) is a preferred approach for separating polar, weakly UV-absorbing compounds such as monosaccharides and disaccharides. Reliable, rapid sugar analysis is important across food quality control, fermentation monitoring, clinical carbohydrate profiling and research. Using an amino (NH2) HILIC stationary phase combined with evaporative light scattering detection (ELSD) yields robust separations without derivatization and with broadly applicable mobile phases.

Objectives and study overview


This application note demonstrates the separation and detection of five common sugars (xylose, arabinose, fructose, glucose and sucrose) using a Shim-pack GIST NH2 column in HILIC mode. The goal is to present a simple, reproducible LC method suitable for routine analysis that balances speed, resolution and compatibility with ELSD.

Methodology


The method uses a reversed polarity HILIC gradient with a high organic content mobile phase to retain polar saccharides. Key method parameters are summarized below:
  • Column: Shim-pack GIST NH2, 100 mm × 2.1 mm I.D., 3 µm
  • System: Nexera X3
  • Mobile phases: A = water, B = acetonitrile
  • Gradient: 90% B at 0 min → 80% B at 8 min → re-equilibrate to 90% B from 8.01 to 18 min
  • Flow rate: 0.3 mL/min
  • Column temperature: 25 °C
  • Sample solvent: 50% acetonitrile
  • Detection: Evaporative light scattering detector (ELSD)
  • Injection vial: Shim-vial S (product number provided by manufacturer)

HILIC retention is promoted by the high organic content (acetonitrile-rich) mobile phase; sample solvent with substantial organic content minimises peak distortion. The aminopropyl phase provides HILIC retention and can contribute weak ionic interactions, aiding separation of neutral monosaccharides and disaccharides.

Used instrumentation


The demonstration employed Shimadzu instrumentation and consumables: Nexera X3 UHPLC system, Shim-pack GIST NH2 column (100 × 2.1 mm, 3 µm) and Shim-vial S sample vials. ELSD was used for detection due to the lack of strong UV chromophores for sugars. Product numbers referenced in the original method are retained in the Reference section.

Main results and discussion


The method successfully separated five analytes—xylose, arabinose, fructose, glucose and sucrose—within the chromatographic window shown (peaks eluting within approximately the first 9 minutes). The applied gradient and high organic fraction provide adequate retention and resolution for the target sugars; subsequent re-equilibration to 90% acetonitrile ensures column stability for successive injections.

Key discussion points:
  • ELSD is well suited for sugar detection because it is independent of chromophores; however, response is typically non-linear and sensitive to mobile phase volatility and detector settings, so calibration and detector optimization are necessary.
  • The NH2 stationary phase combines HILIC interactions with potential weak ionic contributions; this can improve selectivity among closely related saccharides but may be sensitive to buffer/additive choice if ionic strength is changed.
  • Sample solvent composition (50% acetonitrile) helps match injection solvent to the high-organic mobile phase and prevents peak broadening or fronting.
  • Total cycle time includes the analysis window and re-equilibration (gradient returns to initial conditions by 8.01–18 min), allowing robust repeatability between injections.

Practical benefits and applications


This HILIC-ELSD method offers several practical advantages:
  • No derivatization required, reducing sample preparation time and potential artifacts.
  • Sufficient speed for routine quality-control workflows (major analytes elute within ~9 min per injection window).
  • Compatibility with common sample matrices encountered in food, beverage and fermentation samples when appropriate sample cleanup is applied.
  • Simplicity of mobile phases (acetonitrile/water) facilitates method transfer and instrument maintenance.

Future trends and potential applications


Expected developments and opportunities related to carbohydrate analysis by HILIC include:
  • Integration with mass spectrometric detection to provide structural information and enhanced sensitivity, particularly for complex matrices or isomeric carbohydrates.
  • Use of alternative hydrophilic stationary phases (zwitterionic, polymeric or tailored chemistries) to improve isomer separation and robustness under diverse sample conditions.
  • Faster separations using sub-2 µm or superficially porous particles combined with UHPLC platforms to reduce cycle time while maintaining resolution.
  • Detector evolution (charged aerosol detection, improved ELSD designs) and better calibration strategies to address non-linearity and quantitative performance for non-chromophoric analytes.
  • Automation of sample preparation (online dilution, SPE) to increase throughput in routine QC environments.

Conclusion


The presented Shim-pack GIST NH2 HILIC method with ELSD detection provides a practical, reproducible approach for separating common monosaccharides and a disaccharide without derivatization. It balances speed and selectivity for routine applications in food and process analytics. Careful attention to mobile phase composition, sample solvent, detector settings and column re-equilibration is essential for consistent performance.

Reference


  • Shim-pack GIST NH2 column, 100 × 2.1 mm I.D., 3 µm. Product number referenced in original application note.
  • Shim-vial S sample vial. Product number referenced in original application note.
  • Nexera X3 and related trademarks: Shimadzu Corporation (manufacturer and source of the original method description).

Content was automatically generated from an orignal PDF document using AI and may contain inaccuracies.

Downloadable PDF for viewing
 

Similar PDF

Analysis of Voglibose by Post-Column Derivatization Method
Shim-pack HPLC Column Guidebook - High Performance Liquid Chromatography Columns
Analysis of Monosaccharides in Fruit Juice
Shim-pack HPLC Column Guidebook