Analysis of N-nitroso-nebivolol, Nitroso Drug Substance Related impurity in Nebivolol 20 mg tablet formulation using LC-MS/MS system

Posters | 2025 | Agilent Technologies | ASMSInstrumentation
LC/MS, LC/MS/MS, LC/QQQ
Industries
Pharma & Biopharma
Manufacturer
Agilent Technologies

Significance of the Topic


The quantification of N-nitroso-nebivolol, a genotoxic impurity classified by the FDA with a stringent intake limit of 1,500 ng/day, is essential for ensuring patient safety and meeting regulatory standards in hypertension medication quality control.

Objectives and Study Overview


This study aimed to develop and validate a highly specific, sensitive, and reproducible LC-MS/MS method for the determination of N-nitroso-nebivolol in a 20 mg nebivolol tablet formulation. Key goals included achieving sub-picogram detection limits, robust quantitation across a wide calibration range, and clear separation of the impurity from the active pharmaceutical ingredient (API).

Employed Methodology and Instrumentation


  • Chromatographic system: Agilent 1290 Infinity III UHPLC coupled to an Agilent 6495D triple quadrupole mass spectrometer.
  • Column: Agilent Pursuit XRs 3 µm Diphenyl, 150 mm × 3 mm.
  • Mobile phases: A) 1 mM ammonium trifluoroacetate + 0.004 % formic acid in water; B) Methanol; flow rate 0.5 mL/min; injection volume 10 µL.
  • MS conditions: Jet Stream ESI source in positive mode; MRM transition m/z 435.2 → 254.0 selected for impurity detection.
  • Sample preparation: Tablets ground to powder, dispersed to 0.6 mg/mL nebivolol in diluent, vortexed, shaken, and centrifuged. API, placebo, and spiked QC samples processed similarly.

Main Results and Discussion


  • Chromatographic separation of impurity and API achieved in approximately 10 minutes using a software-controlled diverter to prevent high-concentration API interference.
  • Calibration curve: 13 concentration levels spanning 5 pg/mL to 50 ng/mL with 1/x weighting, yielding R² = 0.997.
  • Detection limits: LOD = 2 pg/mL (S/N > 20:1), LOQ = 5 pg/mL (S/N > 50:1).
  • Reproducibility: %RSD ~3.1 % for six replicate injections at the LOQ level.
  • Spike recovery at 200 pg/mL: 116.8 % in API, 108.3 % in placebo, and 111.8 % in tablet matrix, demonstrating efficient extraction and accuracy.

Benefits and Practical Applications


The validated method supports routine quality control of nebivolol tablets by enabling trace-level determination of a critical genotoxic impurity, ensuring compliance with international safety guidelines and enhancing laboratory throughput.

Future Trends and Potential Applications


  • Adaptation for analysis of other nitrosamine impurities across various pharmaceutical formulations.
  • Integration with automated sample preparation systems to further improve throughput and consistency.
  • Employment of high-resolution mass spectrometry for comprehensive impurity profiling in complex matrices.

Conclusion


A robust and sensitive LC-MS/MS method was successfully established for N-nitroso-nebivolol quantitation in nebivolol tablets, achieving sub-picogram sensitivity, excellent linearity, reproducibility, and recovery, thus meeting stringent regulatory requirements for impurity control.

Reference


  • Prasanth J., Banerjee S., Vyas S. Determination of Genotoxic Nitrosamine Impurity in Bumetanide API and Tablets Using the Agilent 6470 Triple Quadrupole LC/MS. Agilent Technologies application note, 5994-2967EN, 2020.

Content was automatically generated from an orignal PDF document using AI and may contain inaccuracies.

Downloadable PDF for viewing
 

Similar PDF

Quantitation of N-Nitroso Nebivolol in Nebivolol Tablet Formulation
Quantitation of N-Nitroso Hydrochlorothiazide in Losartan- Hydrochlorothiazide Tablets
Quantitation of N-Nitroso Moxifloxacin in 400 mg Moxifloxacin Tablet Formulation
Determination of Genotoxic Nitrosamine Impurity in Bumetanide API and Tablets Using the Agilent 6470 Triple Quadrupole LC/MS