LC/MS, LC/MS/MS, LC/QQQ
IndustriesPharma & Biopharma
ManufacturerAgilent Technologies
Significance of the Topic
Losartan and hydrochlorothiazide combination therapy is widely prescribed for hypertension, but N-nitroso impurities pose safety concerns. Sensitive detection of N-nitroso HCTZ ensures drug safety and regulatory compliance.
Objectives and Study Overview
- Develop a sensitive and reproducible MRM LC/MS/MS method for N-nitroso HCTZ quantification in losartan-HCTZ tablets
- Establish method sensitivity, linearity, and reproducibility
- Apply the method for routine quality control and impurity monitoring
Methodology
Sample preparation involved tablet crushing, dilutions in methanol:water, and spiking placebo and tablet matrices at LOQ levels. Calibration standards ranged from 10 pg/mL to 10 ng/mL. Chromatography used an Agilent ZORBAX SB C18 column (4.6 × 150 mm, 5 µm) with a gradient of 1 mM ammonium fluoride in water (A) and acetonitrile (B) at 0.3 mL/min, injection volume 20 µL, and column temperature 40 °C.
Mass spectrometry operated in negative electrospray mode using MRM transition 325.0→293.9 m/z for N-nitroso HCTZ with optimized fragmentor and collision energy. Method validation covered linearity, LOD/LOQ, reproducibility, specificity, and recovery.
Used Instrumentation
- Agilent 1290 Infinity II LC system (high-speed pump, multisampler, multicolumn thermostat, diode array detector)
- Agilent 6495D Triple Quadrupole LC/MS/MS system with Jet Stream ion source
Key Results and Discussion
Chromatographic separation ensured clear resolution of N-nitroso impurity from losartan and HCTZ APIs, with a diverter valve diverting API elution to waste. The method achieved:
- LOD of 5 pg/mL and LOQ of 10 pg/mL with S/N of 121:1 at LOQ
- Linearity from 10 pg/mL to 10 ng/mL (R² = 0.9952)
- Spike recoveries of 114.35% in placebo and 93.85% in tablets
- %RSD of 2.7% for seven replicate injections at LOQ
Benefits and Practical Applications
- Ensures sensitive and reliable detection of nitrosamine impurities in combination drugs
- Supports compliance with regulatory limits and safety guidelines
- Facilitates routine quality control and impurity profiling
Future Trends and Potential Applications
- Extension of the method to other nitrosamine impurities and drug matrices
- Integration with high-resolution mass spectrometry for structural confirmation
- Automation for high-throughput screening in pharmaceutical QC labs
- Online and in-line monitoring for continuous manufacturing processes
Conclusion
The developed MRM LC/MS/MS method on the Agilent 6495D system offers high sensitivity, robustness, and reproducibility for quantifying N-nitroso HCTZ in losartan-HCTZ tablets, providing a valuable tool for pharmaceutical quality assurance and regulatory compliance.
Reference
- Mastovska K.; Zulkoski J.; Zweigenbaum J. Triggered MRM LC/MS/MS Method Development – Practical Considerations for MRM Optimization Using Agilent MassHunter Optimizer Software. Agilent Technologies, 2017.
- Sosienski T.; Covert K. Trace-Level Quantification of Potential Mutagenic Impurities in Pharmaceuticals. Agilent Technologies, 2019.
- Joseph P.; Banerjee S.; Vyas S. Determination of Genotoxic Nitrosamine Impurity in Bumetanide API and Tablets Using the Agilent 6470 Triple Quadrupole LC/MS. Agilent Technologies, 2020.
Content was automatically generated from an orignal PDF document using AI and may contain inaccuracies.