Highly Sensitive Quantitation of N-Nitroso Timolol Impurity in Timolol API using the Agilent 6495D LC/TQ

Posters | 2025 | Agilent Technologies | ASMSInstrumentation
LC/MS, LC/MS/MS, LC/QQQ
Industries
Pharma & Biopharma
Manufacturer
Agilent Technologies

Importance of the Topic


Nitrosamine impurities in pharmaceuticals are potent mutagens and potential carcinogens.
Regulatory agencies have imposed strict limits on nitrosamine drug substance-related impurities after several product recalls to safeguard patients.
Screening APIs such as timolol for N-nitroso derivatives is essential for quality control and compliance.

Objectives and Study Overview


  • Develop a sensitive and specific LC–TQ method for quantifying N-nitroso timolol in timolol API.
  • Achieve detection limits below 10% of the specified threshold.
  • Validate the method in accordance with ICH guidelines.

Methodology and Instrumentation


The analysis employed reversed-phase chromatography on an Agilent InfinityLab Poroshell Phenyl-Hexyl column (150×3.0 mm, 2.7 μm) coupled to an Agilent 6495D triple quadrupole mass spectrometer and 1290 Infinity II LC.
  • Mobile Phase A: 1 mM ammonium trifluoroacetate with 0.05% formic acid in water.
  • Mobile Phase B: 0.1% formic acid in methanol.
  • Gradient elution over 20 minutes at 0.4 mL/min and 40 °C column temperature.
  • MRM transitions for N-nitroso timolol: m/z 346.2→128, 346.2→144, 346.2→130 with optimized collision energies.

Source settings included positive AJS-ESI, 3000 V capillary voltage, 12 L/min gas flows, and ionization temperatures of 250–350 °C.

Main Results and Discussion


  • Linearity: 5–1500 pg/mL (0.5–150 ppb) with R² > 0.9990 using 1/x² weighting.
  • LOD: 2 pg/mL (0.2 ppb) with S/N > 118:1; LOQ: 5 pg/mL (0.5 ppb) with S/N > 1680:1.
  • Precision: %RSD below 5% across six replicate injections at LOD, LOQ, and mid-range levels.
  • Recovery: 98.5% average at 50 pg/mL spike (5 ppb) in API matrix, within 90–110% criteria.
  • Chromatographic separation achieved baseline resolution at retention time ~8.96 min, confirmed by UV and MRM traces.

Benefits and Practical Applications


  • Enables reliable monitoring of trace-level nitrosamines in timolol API.
  • Supports compliance with global regulatory requirements for nitrosamine limits.
  • Methodology adaptable to other pharmaceutical nitrosamine analyses.

Future Trends and Opportunities


  • Expansion of MRM workflows to cover multiple nitrosamine impurities.
  • Automation of sample preparation for higher throughput.
  • Integration of high-resolution mass spectrometry for confirmation and structure elucidation.

Conclusion


The developed LC/TQ method delivers high sensitivity, precision, and accuracy for quantifying N-nitroso timolol at trace levels, ensuring robust quality control and regulatory compliance in pharmaceutical production.

Reference


  1. FDA Guidance: Recommended Acceptable Intake Limits for Nitrosamine Drug Substance-Related Impurities, CDER, August 2023.
  2. Agilent Application Note 5994-7066E: Low-Level Quantitation of N-Nitroso Dabigatran Etexilate Impurity Using the Agilent 6495C LC/TQ.

Content was automatically generated from an orignal PDF document using AI and may contain inaccuracies.

Downloadable PDF for viewing
 

Similar PDF

Sensitive and Selective Quantitation of N- Nitroso Dabigatran Etexilate Impurity in Dabigatran Etexilate API using the Agilent 6495C LC/TQ
Low-Level Quantitation of N-Nitroso Dabigatran Etexilate Impurity in Dabigatran Etexilate Mesylate API Using the Agilent 6495C LC/TQ
Highly Sensitive Quantification of Mutagenic NDSRI N-Nitroso Propranolol in Propranolol API and 40 mg Tablets Using LC/MS/MS
Quantitation of N-Nitroso Sitagliptin Impurity (NTTP) in Sitagliptin and Metformin Combination Drug Product Using the Agilent 6475 LC/TQ