Pushing the limits for trace elemental analysis using triple quadrupole ICP-MS

Others | 2025 | Thermo Fisher ScientificInstrumentation
ICP/MS, ICP/MS/MS
Industries
Energy & Chemicals
Manufacturer
Thermo Fisher Scientific

Importance of the topic


Trace elemental analysis underpins quality control, safety and environmental monitoring across industries. Ultra-low concentration measurements are critical for detecting contaminants in water, pharmaceuticals, food and medical solutions. Achieving accurate quantification at parts-per-trillion levels demands advanced instrumentation and robust methods to overcome matrix interferences and maintain high throughput.

Objectives and study overview


This case study evaluates the performance of a triple quadrupole ICP-MS system (iCAP MTX) at Ultra Trace Analysis Aquitaine (UT2A). Key goals included pushing detection limits for challenging matrices, optimizing sample preparation and generating standardized operating procedures for routine ultra-trace analysis across diverse sample types.

Methodology and instrumentation


UT2A deployed the Thermo Scientific iCAP MTX ICP-MS equipped with:
  • Triple quadrupole cell with Kinetic Energy Discrimination mode
  • Reactive gas capabilities for advanced interference removal
  • Intelligent Matrix Handling (iMH) and Easy Argon Gas Dilution (Easy AGD)
  • Redesigned sample introduction interface with EasyClick pump
  • Qtegra ISDS software for data acquisition, QC monitoring and instrument control

Approximately 200 samples per day were analyzed twice weekly over ten months, with frequent standards, blanks and QC checks incorporated through IQ/OQ qualification.

Main results and discussion


The iCAP MTX ICP-MS demonstrated:
  • Iron quantification at 0.1 µg/L in 1 g/L NaCl matrix with minimal dilution
  • Accurate selenium measurement in gadolinium-rich samples via triple quad interference removal
  • Negligible salt deposition on cones and interface, even with undiluted seawater
  • Reduced maintenance frequency and simplified cone cleaning due to improved interface design

Overall sensitivity and stability significantly surpassed previous ICP-MS generations, enabling reliable ultra-trace measurements in high total dissolved solid samples.

Benefits and practical applications


Implementation of the triple quadrupole ICP-MS yielded:
  • Lower detection limits and enhanced data quality for environmental and industrial samples
  • Streamlined workflows and reduced downtime through automated dilution and matrix handling
  • Customizable QC alerts and integrated maintenance tracking via Qtegra software

These improvements support routine testing, method development and transfer of ready-to-use SOPs to client laboratories.

Future trends and possibilities for use


Advances may include integration of artificial intelligence for real-time data evaluation, further miniaturization of interface components, expanded use of reactive gas chemistries and enhanced automation to support ever-stricter regulatory requirements and complex sample matrices.

Conclusion


The iCAP MTX ICP-MS system proved highly effective for ultra-trace elemental analysis, offering exceptional sensitivity, robust performance in challenging matrices and simplified maintenance. Its adoption can elevate laboratory throughput and confidence in low-level quantification, making it a recommended solution for advanced analytical facilities.

Reference


Thermo Fisher Scientific Inc. Case study CS003716-EN, 2025.

Content was automatically generated from an orignal PDF document using AI and may contain inaccuracies.

Downloadable PDF for viewing
 

Similar PDF

Thermo Scientific iCAP MTX triple quadrupole ICP-MS
Thermo Scientific iCAP MTX triple quadrupole ICP-MS
2024|Thermo Fisher Scientific|Brochures and specifications
Thermo Scientific iCAP MTX ICP-MS
Thermo Scientific iCAP MTX ICP-MS
2024|Thermo Fisher Scientific|Technical notes
Supporting development and production with elemental analysis in life sciences and beyond
Analysis of fluorine, chlorine, bromine, and iodine at low levels using triple quadrupole ICP-MS