Converting Target Analysis of Organochlorine Pesticides in Environmental Matrices from Electron Ionization GC-HRMS Using Helium Carrier Gas to Atmospheric Pressure Ionization GC-MS/MS Using Nitrogen Carrier Gas

Applications | 2024 | WatersInstrumentation
GC/API/MS, LC/MS, LC/MS/MS, LC/QQQ, GC/MSD, GC/MS/MS, GC/QQQ
Industries
Environmental
Manufacturer
Waters

Importance of the Topic


The persistence and bioaccumulation of organochlorine pesticides (OCPs) in environmental matrices pose long‐term risks to ecosystems and human health. Compounds such as DDT exhibit half‐lives in sediment up to 15 years and remain detectable for decades. Monitoring OCP levels in sediment and biota is essential for understanding pollutant fate, transport, and potential effects on food webs, particularly in remote regions impacted by climate change.

Objectives and Study Overview


This study evaluates the transfer of a reference electron ionization gas chromatography high‐resolution mass spectrometry (EI-GC-HRMS) method for 39 target OCPs to an atmospheric pressure gas chromatography tandem quadrupole mass spectrometry (APGC-MS/MS) platform. It compares performance using helium versus nitrogen carrier gases, examines chromatographic alignment with the reference method, and assesses quantitative agreement in sediment and biota extracts.

Methodology and Instrumentation

  • Sample Preparation: Soxhlet extraction of sediment (toluene) and biota (hexane:acetone 1:1) followed by gel permeation and silica cleanup.
  • APGC-MS/MS System: Xevo TQ-XS with APGC+ ion source, operating in charge‐exchange mode. Multiple reaction monitoring (MRM) acquisition.
  • Carrier Gas Configurations: Helium on a 60 m × 0.25 mm column at 1.5 mL/min; nitrogen on a scaled 40 m × 0.18 mm column at 0.45 mL/min.
  • Reference System: Autospec Premier magnetic sector MS with EI at 35 eV, using a 60 m × 0.25 mm DB-5 column at 1.0 mL/min.
  • Temperature Program: Identical 39-minute gradient for all analyses to maintain comparability.

Key Results and Discussion

  • Chromatographic Matching: Helium APGC and the reference EI-GC-HRMS method achieved equivalent retention times and resolution. Nitrogen APGC on the scaled column matched helium results within an average of 1.1 seconds.
  • Sensitivity: Both carrier gases provided comparable detection limits within a two-fold range; linear calibration from 1 to 200 ppb yielded R2 values >0.996.
  • Quantitative Agreement: Four real‐world sediment and biota samples run on APGC-N2 showed average agreement within 20% of the reference method for analytes >1 ppb. Restricting to 2–200 ppb improved agreement to <11%.
  • Low‐Level Detections: Examples include trans-nonachlor at 2.5 ppb and dieldrin at 18.9 ppb with clear baselines despite 250× zoom.

Benefits and Practical Applications

  • Compact and cost‐effective alternative to magnetic sector GC-EI-HRMS, reducing instrument footprint and capital expenditure.
  • Shortened operator training time—from months to weeks—due to APCI simplicity.
  • Use of nitrogen carrier gas enhances sustainability, lowers operational cost, and improves supply reliability compared to helium.
  • Seamless method transfer allows reuse of MRM acquisition and data processing workflows across carrier gases.

Future Trends and Possibilities


The demonstrated success of APGC-MS/MS for OCP analysis suggests broader adoption of atmospheric pressure ionization techniques across environmental laboratories. Transitioning to sustainable nitrogen gas supports green analytical chemistry initiatives. Ongoing refinements in ion source design, expanded MRM libraries, and integration with high-throughput sample preparation will further advance trace pollutant monitoring in complex matrices.

Conclusion


This application study confirms that APGC-MS/MS with either helium or nitrogen carrier gas can replicate and, in some cases, surpass the performance of traditional EI-GC-HRMS methods for organochlorine pesticide analysis. The approach offers equivalent chromatographic resolution, robust quantification, and practical benefits in cost, training, and sustainability.

References

  1. National Pesticide Information Center. DDT General Fact Sheet. 2024.
  2. UN Environment Programme. The 12 Initial POPs under the Stockholm Convention. 2004.
  3. Van Bavel B., et al. APGC/MS/MS vs. HRGC/HRMS for Dioxins. Anal. Chem. 2015;87(17):9047–9053.
  4. De Wit C.A., Vorkamp K., Muir D. Influence of Climate Change on POPs in the Arctic. Environ. Sci.: Process. Impacts. 2022;24(10):1530–1543.
  5. Karasek F.W., Onuska F.I. Trace Analysis of the Dioxins. Anal. Chem. 1982;54(2):309–324.
  6. Yost R.A. The Triple Quadrupole: Innovation and Persistence. J. Mass Spectrom. Adv. Clin. Lab. 2022;24:90.
  7. EU Commission Regulation No. 589/2014 on Dioxins and PCBs in Foodstuffs. 2014.
  8. Stevens D., Dorman F., Hancock P. Converting Semivolatile GC-MS/MS Methods to Nitrogen with APGC. 2023.
  9. Smalling K.L., Kuivila K.M. Multi‐Residue Method for 85 Pesticides in Sediments. J. Chromatogr. A. 2008;1210(1):8–18.

Content was automatically generated from an orignal PDF document using AI and may contain inaccuracies.

Downloadable PDF for viewing
 

Similar PDF

Analysis of Halogenated Flame Retardants Using Atmospheric Pressure Chemical Ionization GC-MS/MS
Analysis of Polybrominated Diphenyl Ether Flame Retardants in Environmental Matrices Using Atmospheric Pressure Chemical Ionization GC-MS/MS
High Temperature Gas Chromatography Analysis of Polycyclic Aromatic Hydrocarbons (PAHs) Using Atmospheric Pressure Chemical Ionization GC/MS/MS
Harnessing the Efficiency of Nitrogen Carrier Gas with the Atmospheric Pressure Gas Chromatography (APGC) Source