Significance of the Topic


Per- and polyfluoroalkyl substances (PFAS) are persistent environmental contaminants found in food and agricultural matrices. Their chemical stability, widespread use, and potential health risks make sensitive and reliable analytical methods essential for regulatory compliance and public health protection.

Objectives and Study Overview


This application note evaluates the Agilent 1260 Infinity II Hybrid Multisampler in feed injection mode to enhance the quantification sensitivity of 47 PFAS analytes by LC/MS/MS. The study compares traditional flow-through injections with feed injections, focusing on peak shape, linearity, and detection limits across a range of injection volumes and solvent compositions.

Methodology and Instrumentation


The method employs an Agilent InfinityLab Poroshell 120 Aq-C18 column operated at 55 °C, with water and methanol gradients containing 5 mM ammonium acetate. The Hybrid Multisampler performs online dilution by infusing the sample into the mobile phase at 10% of flow rate, minimizing solvent effects and focusing analytes on the column. A low-background PFAS LC/MS kit and Agilent Ultivo Triple Quadrupole MS were used under negative polarity with standard MRM transitions.

Main Results and Discussion


Feed injection enabled injection volumes up to 40 µL without peak broadening or breakthrough. Early-eluting polar PFAS exhibited improved peak sharpness, and branched isomers were resolved accurately. Peak height increased by factors of 2.1–3.7 compared to flow-through injections, with linearity coefficients (R²) ≥ 0.99 and area RSDs below 1.3% for 40 µL injections.

Benefits and Practical Applications


  • Enhanced sensitivity and lower detection limits enable trace PFAS monitoring.
  • Robust quantification of branched and early-eluting isomers without manual integration.
  • Higher throughput via larger injection volumes without complex sample preparation.

Future Trends and Applications


Feed injection may be integrated into routine PFAS analysis workflows in environmental, food, and agricultural testing laboratories. Emerging LC column chemistries and further optimization of dilution strategies could extend this approach to other challenging polar analytes and high-organic matrices.

Conclusion


The Agilent 1260 Infinity II Hybrid Multisampler feed injection significantly reduces solvent effects, sharpens peaks, and improves quantitative linearity for PFAS. It offers a simple, high-sensitivity alternative to flow-through injection, enabling reliable trace analysis and streamlined workflows.

Used Instrumentation


  • Agilent 1290 Infinity II High Speed Pump (G7120A)
  • Agilent 1260 Infinity II Hybrid Multisampler (G7167C)
  • Agilent 1290 Infinity II Multicolumn Thermostat (G7116B)
  • Agilent Ultivo Triple Quadrupole LC/MS (G6465B)
  • Agilent InfinityLab Poroshell 120 Aq-C18 Column (2.1×100 mm, 2.7 µm, PN 695775-742)

References


  • Zarębska M.; Bajkacz S. Poly- and Perfluoroalkyl Substances (PFAS) - Recent Advances in the Aquatic Environment Analysis. Trends Anal. Chem. 2023. DOI:10.1016/j.trac.2023.117062
  • U.S. EPA. National Primary Drinking Water Regulations for PFAS. 2023.
  • Agilent Technologies. Ultra-Trace Quantification of PFAS in Drinking Water. Application Note 5994-5797EN, 2023.
  • Agilent Technologies. Performance Characteristics of the 1260 Infinity II Hybrid Multisampler. Tech. Overview 5994-5952EN, 2023.
  • Agilent Technologies. Reduce PFAS Background with the PFC-Free HPLC Conversion Kit. Tech. Overview 5994-2291EN, 2021.

Content was automatically generated from an orignal PDF document using AI and may contain inaccuracies.

Downloadable PDF for viewing
 

Similar PDF

Quantitative PFAS Analysis in Medical Devices Using Triple Quadrupole LC/MS
Chromatographic Performance Comparison in Ultrashort-Chain PFAS Analysis
Analysis of >50 Legacy and Emerging PFAS in Water Using the Agilent 6495B Triple Quadrupole LC/MS
Using Agilent Hybrid Multisamplerwith Triple Quadrupole Mass Spectrometer to Solve Solvent Effect in PFCAs and its Precursor FTOHs Analysis