High throughput proteomics Application of dia PASEF and Evosep One for short gradients

Posters | 2020 | BrukerInstrumentation
Ion Mobility, LC/TOF, LC/HRMS, LC/MS, LC/MS/MS
Industries
Proteomics
Manufacturer
Bruker

Importance of the topic


High-throughput proteomic analyses that deliver deep coverage and reproducible quantification are essential for large-scale biological and clinical studies. Short LC gradients with robust data-independent acquisition enable rapid turnaround while maintaining data quality.

Objectives and study overview


This work evaluates the integration of dia-PASEF (data-independent acquisition Parallel Accumulation–Serial Fragmentation) with the Evosep One chromatography system for very short gradients. The aim is to assess throughput, proteome depth, and quantitation precision in single-shot analyses of complex samples.

Methodology


An in-house tryptic HeLa cell digest served as a complex model. Key steps included:
  • Coupling the Evosep One system to a timsTOF Pro mass spectrometer.
  • Implementing a dia-PASEF scheme with 24 windows of 25 Da covering m/z 400–1,000 and a total cycle time of 900 ms.
  • Generating a resource-specific library by DDA-PASEF fractionation (24 fractions, ~10 hours at 60 samples per day).
  • Creating hybrid spectral libraries for 100, 200, and 300 SPD methods by combining resource-specific data with directDIA runs.

Used instrumentation


  • Evosep One liquid chromatography system (Evosep Biosystems)
  • timsTOF Pro mass spectrometer with trapped ion mobility and PASEF (Bruker Daltonics)

Main results and discussion


  • At 60 samples per day (SPD) with a 6-minute gradient, an average of 5 204 protein groups and 39 936 peptides were identified at 1% FDR.
  • Shorter gradient formats (100, 200, 300 SPD) retained high identification rates and quantitative precision.
  • The fastest method (300 SPD: 3-minute gradient, 5-minute total run) yielded over 2 100 protein groups and 10 462 peptides per run.
  • Median coefficients of variation were 8.2% at the peptide level and 5.9% at the protein level across triplicates.
  • Quantitative dynamic range spanned approximately five orders of magnitude.

Benefits and practical applications


  • Enables single-shot deep proteome profiling for hundreds of samples per day.
  • Delivers high reproducibility and quantitative accuracy suitable for cohort studies.
  • Reduces instrument time and operational costs through ultra-short gradients.

Future trends and possibilities


  • Integration into clinical and industrial workflows for large-scale biomarker discovery.
  • Improvements in library generation and real-time data processing to further enhance speed and depth.
  • Extension to diverse sample types and potential use in point-of-care proteomic diagnostics.

Conclusion


The combination of dia-PASEF on the timsTOF Pro with the Evosep One system achieves unprecedented throughput and robust proteome coverage using very short chromatographic gradients. This platform is well suited for large-scale quantitative proteomics applications.

Content was automatically generated from an orignal PDF document using AI and may contain inaccuracies.

Downloadable PDF for viewing
 

Similar PDF

High throughput 4D-Proteomics – Application of dia-PASEF® and the Evosep One for short gradients
diaPASEF: label-free quantification of highly complex proteomes
dia-PASEF® applied on different gradient lengths
Parallel accumulation – serial fragmentation combined with data-independent acquisition (diaPASEF)