Sample Preparation, Consumables, LC/MS, LC/MS/MS, LC/QQQ
IndustriesClinical Research
ManufacturerWaters
Importance of the Topic
The widespread use and environmental persistence of per- and polyfluoroalkyl substances (PFAS) have led to their accumulation in human tissues. Monitoring PFAS in serum provides critical insight into exposure pathways, bioaccumulation trends, and potential health risks. A reliable extraction and analysis protocol for multiple PFAS is essential for occupational health, environmental exposure assessment, and epidemiological studies.
Objectives and Study Overview
This study aimed to develop and validate a robust, high-throughput solid phase extraction (SPE) method coupled with LC-MS/MS for quantifying 30 PFAS in human serum. The method leverages weak anion exchange (WAX) chemistry for cleanup and a Xevo TQ-S micro tandem quadrupole mass spectrometer to achieve sensitive, selective detection. Method performance was assessed using pooled human serum lots and a NIST standard reference material (SRM 1957).
Methodology
Sample preparation employed Oasis WAX µElution 96-well plates. Human serum or PFAS-free fetal bovine serum (for calibration) underwent protein precipitation (1:3 serum:acetonitrile) and acid dilution to disrupt PFAS–protein binding. After loading, plates were washed to remove interferences and eluted for analysis.
Used Instrumentation
- UPLC system: ACQUITY UPLC I-Class PLUS modified with PFAS kit
- Column: ACQUITY UPLC HSS T3, 2.1 × 100 mm, 1.8 µm, 35 °C
- Mass spectrometer: Xevo TQ-S micro, ESI negative mode
- Software: MassLynx 4.2 with TargetLynx XS for data processing
Main Results and Discussion
Optimization of sample pretreatment demonstrated that 1:3 acetonitrile protein precipitation minimized PFAS breakthrough compared to direct acid dilution. Column selection was critical: the HSS T3 phase resolved PFAS from coeluting steroid sulfates better than a BEH C18 column, improving quantitation accuracy. Calibration curves in FBS ranged from 0.05 to 20 ng/mL with R² ≥ 0.996 (except 6:2 FTS at 0.992). Residuals were ≤15% at LOQ and ≤10% elsewhere. Recoveries across six pooled serum lots were 85–120% for 29 PFAS; FBSA showed ~20% recovery due to its neutral chemistry. Analysis of NIST SRM 1957 (eight replicates) yielded values within ±10% of certified concentrations with RSD <4%, confirming accuracy and robustness. Application to six human serum pools revealed variable total PFAS levels and isomer ratios, enabling potential exposure fingerprinting.
Benefits and Practical Applications
- High-throughput, accurate PFAS quantitation in complex serum matrices
- Reduced instrument maintenance through efficient cleanup
- Applicability to occupational health, environmental biomonitoring, and toxicology
- Capability to distinguish isomeric profiles for source identification
Future Trends and Potential Applications
Advancements may include expansion to non-target PFAS screening, integration of high-resolution mass spectrometry for unknowns, automation of sample preparation, and correlation of PFAS fingerprints with exposure sources in large-scale epidemiological studies. Emerging extraction chemistries may improve recovery of neutral or low-molecular-weight PFAS.
Conclusion
The presented SPE-UPLC-MS/MS method offers a reliable, sensitive, and reproducible approach for quantifying a broad range of PFAS in human serum. Validation with multiple serum sources and certified reference material demonstrates its suitability for routine biomonitoring and research applications.
Reference
- Post GB, Cohn PD, Cooper KR. Perfluorooctanoic Acid (PFOA), An Emerging Drinking Water Contaminant: A Critical Review of Recent Literature. Environ Res. 2012;116:93–117.
- Zeng Z, et al. Assessing the Human Health Risks of Perfluorooctane Sulfonate by In Vivo and In Vitro Studies. Environ Int. 2019;126:598–610.
- United States Environmental Protection Agency. Health Effects Support Document for Perfluorooctane Sulfonate (PFOS). EPA 822-R-16-002; 2016.
- United States Environmental Protection Agency. Health Effects Support Document for Perfluorooctanoic Acid (PFOA). EPA 822-R-16-003; 2016.
- Sunderland EM, et al. A Review of the Pathways of Human Exposure to Poly- and Perfluoroalkyl Substances (PFAS) and Present Understanding of Health Effects. J Expo Sci Environ Epidemiol. 2019;29(2):131–147.
- Huber S, Brox J. An Automated High-Throughput SPE Micro-Elution Method for Perfluoroalkyl Substances in Human Serum. Anal Bioanal Chem. 2015;407(13):3751–3761.
- Chan E, et al. Endogenous High-Performance Liquid Chromatography/Tandem Mass Spectrometry Interferences and the Case of Perfluorohexane Sulfonate (PFHxS) in Human Serum. Rapid Commun Mass Spectrom. 2009;23(10):1405–1410.
Content was automatically generated from an orignal PDF document using AI and may contain inaccuracies.