▾
EN
▾
Branch
ALL
ICPMS
LCMS
Menu
News
Articles
Events
Academy
Coming soon
Library
Webinars
Products
Instruments and services
Marketplace
Companies
Commercial
Non-Commercial
Media
Career
Job offers
All branches
ICPMS
LCMS
Account
Log in
Register
▾
News
▾
Library
Webinars
Products
▾
Companies
▾
Career
▾
EN
▾
Databases
GCMS_EN
LCMS_EN
ICPMS_EN
Industries
Clinical Research
Forensics
(17)
Clinical Research
Instrumentation
Consumables
(22)
GC/MSD
(17)
GC/SQ
(16)
Sample Preparation
(22)
Manufacturer
Agilent Technologies
(15)
Biotage
Biotage
Author
Biotage
(22)
Content Type
Applications
(19)
Guides
(1)
Technical notes
(2)
Publication Date
Applications from the field of Clinical Research - page 2
Open paper Extraction of Benzodiazepines from Whole Blood Using ISOLUTE® SLE+ Prior to GC/MS Analysis
Extraction of Benzodiazepines from Whole Blood Using ISOLUTE® SLE+ Prior to GC/MS Analysis
GC/MSD, Sample Preparation, GC/SQ, Consumables
Instrumentation
GC/MSD, Sample Preparation, GC/SQ, Consumables
Manufacturer
Agilent Technologies, Biotage
Industries
Forensics , Clinical Research
Open paper Extraction of Amphetamine and Designer Amphetamine Analogues from Whole Blood Using ISOLUTE® SLE+ Prior to GC/MS Analysis
Extraction of Amphetamine and Designer Amphetamine Analogues from Whole Blood Using ISOLUTE® SLE+ Prior to GC/MS Analysis
GC/MSD, Sample Preparation, GC/SQ, Consumables
Instrumentation
GC/MSD, Sample Preparation, GC/SQ, Consumables
Manufacturer
Agilent Technologies, Biotage
Industries
Forensics , Clinical Research
Open paper Extraction of Cocaine and Metabolites from Whole Blood Using ISOLUTE® SLE+ Prior to GC/MS Analysis
Extraction of Cocaine and Metabolites from Whole Blood Using ISOLUTE® SLE+ Prior to GC/MS Analysis
GC/MSD, Sample Preparation, GC/SQ, Consumables
Instrumentation
GC/MSD, Sample Preparation, GC/SQ, Consumables
Manufacturer
Agilent Technologies, Biotage
Industries
Forensics , Clinical Research
Open paper Extraction of Propofol from Whole Blood Using ISOLUTE® SLE+ Prior to GC/MS Analysis
Extraction of Propofol from Whole Blood Using ISOLUTE® SLE+ Prior to GC/MS Analysis
GC/MSD, Sample Preparation, GC/SQ, Consumables
Instrumentation
GC/MSD, Sample Preparation, GC/SQ, Consumables
Manufacturer
Agilent Technologies, Biotage
Industries
Clinical Research
Open paper Extraction of Amphetamines and Metabolites from Urine (including Elimination of Sympathomimetic Amine Interferences) Using ISOLUTE® SLE+ Prior to GC/MS Analysis
Extraction of Amphetamines and Metabolites from Urine (including Elimination of Sympathomimetic Amine Interferences) Using ISOLUTE® SLE+ Prior to GC/MS Analysis
GC/MSD, Sample Preparation, GC/SQ, Consumables
Instrumentation
GC/MSD, Sample Preparation, GC/SQ, Consumables
Manufacturer
Agilent Technologies, Biotage
Industries
Forensics , Clinical Research
Open paper Extraction of gamma-Hydroxybutyric Acid (GHB) from Urine Using ISOLUTE® SLE+ Prior to GC/MS Analysis
Extraction of gamma-Hydroxybutyric Acid (GHB) from Urine Using ISOLUTE® SLE+ Prior to GC/MS Analysis
GC/MSD, Sample Preparation, GC/SQ, Consumables
Instrumentation
GC/MSD, Sample Preparation, GC/SQ, Consumables
Manufacturer
Agilent Technologies, Biotage
Industries
Clinical Research
Open paper Extraction of Phencyclidine (PCP) from Urine Using ISOLUTE® SLE+ Prior to GC/MS Analysis
Extraction of Phencyclidine (PCP) from Urine Using ISOLUTE® SLE+ Prior to GC/MS Analysis
GC/MSD, Sample Preparation, GC/SQ, Consumables
Instrumentation
GC/MSD, Sample Preparation, GC/SQ, Consumables
Manufacturer
Agilent Technologies, Biotage
Industries
Clinical Research
Open paper Extraction of Bath Salts (substituted cathinones) From Human Urine using ISOLUTE SLE+ Columns prior to GC-MS Analysis
Extraction of Bath Salts (substituted cathinones) From Human Urine using ISOLUTE SLE+ Columns prior to GC-MS Analysis
GC/MSD, Sample Preparation, GC/SQ, Consumables
Instrumentation
GC/MSD, Sample Preparation, GC/SQ, Consumables
Manufacturer
Agilent Technologies, Biotage
Industries
Clinical Research
Open paper Extraction of Designer Stimulants from Urine Using ISOLUTE® SLE+ prior to GC/MS Analysis
Extraction of Designer Stimulants from Urine Using ISOLUTE® SLE+ prior to GC/MS Analysis
GC/MSD, Sample Preparation, GC/SQ, Consumables
Instrumentation
GC/MSD, Sample Preparation, GC/SQ, Consumables
Manufacturer
Agilent Technologies, Biotage
Industries
Forensics , Clinical Research
Open paper Extraction of Benzodiazepines From Human Urine Using ISOLUTE® SLE+ in Column Format Prior to GC-MS analysis
Extraction of Benzodiazepines From Human Urine Using ISOLUTE® SLE+ in Column Format Prior to GC-MS analysis
GC/MSD, Sample Preparation, GC/SQ, Consumables
Instrumentation
GC/MSD, Sample Preparation, GC/SQ, Consumables
Manufacturer
Agilent Technologies, Biotage
Industries
Forensics , Clinical Research
Prev
1
2
3
Next