MS Imaging, LC/TOF, LC/HRMS, LC/MS, LC/MS/MS
IndustriesForensics
ManufacturerWaters
Importance of the topic
The rising sophistication of cheque forgery causes substantial financial losses and challenges traditional handwriting analysis, which is time-consuming and often fails to detect small-scale alterations.
- Fraudulent modifications can inflate payout amounts or change payee names.
- Handwriting experts struggle with subtle single-character forgeries.
- There is a clear need for objective, molecular-level detection techniques that preserve evidence integrity.
Objectives and study overview
This study evaluates desorption electrospray ionization (DESI) ambient mass spectrometry imaging (MSI) for detecting cheque fraud. A simulated case involved altering a bank cheque originally written for £80,000,000 and changing the recipient’s name. The goal was to map distinct ink chemical signatures to reveal unauthorized changes with minimal or no sample preparation.
Methodology and instrumentation
DESI-MSI was used to perform surface chemical analysis under ambient conditions without extraction or derivatization.
- Three different pens (A, B, C) created the original text and subsequent forgeries.
- A blackout marker concealed the cheque number for recovery tests.
Used instrumentation
- DESI source mounted on a Waters SYNAPT G2-Si QTof mass spectrometer.
- Solvent: 100% methanol at 1.5 µL/min; nebulizing gas: nitrogen at 0.5 MPa; sprayer voltage: 4.5 kV; positive ion mode; m/z range: 50–1200.
- Imaging pixel sizes: 100 µm for broad scans and 50 µm for high-resolution areas.
- Data acquisition in MassLynx 4.2, visualization in HDI 1.4, principal component analysis in EZ Info 2.0.
Key results and discussion
- Unique m/z markers distinguished pen A (original writing), pen B and C (forgery strokes), and blackout marker ink.
- Spatial distribution maps revealed alterations to the numeric amount, written words, and payee name with single-character precision.
- Overlay MS images and PCA of regions of interest segregated the three pen signatures into distinct clusters.
- MS imaging of the blackout pen recovered the obscured cheque number as 100135.
This ambient approach provided unambiguous molecular evidence of forgery while preserving the physical specimen for follow-up analyses.
Benefits and practical applications
- Rapid, objective detection of minute ink alterations undetectable by visual inspection.
- Minimal specimen damage allows subsequent forensic or analytical testing.
- High spatial resolution enables attribution of individual pen strokes.
- Seamless integration into forensic workflows and quality-control processes.
Future trends and applications
- Expansion to negative ion mode for additional molecular markers.
- Higher spatial resolution imaging and 3D surface profiling.
- Integration with complementary techniques such as Raman spectroscopy and DNA analysis.
- Development of automated spectral libraries for rapid ink identification and authentication.
Conclusion
DESI ambient MS imaging demonstrates a powerful capability for forensic cheque analysis, offering precise, non-destructive chemical mapping of inks. This method enhances objectivity, sensitivity, and preserves evidence integrity, with significant potential for broader forensic and industrial quality-control applications.