Agilent 7200 Q-TOF for GC/MS

Brochures and specifications | 2012 | Agilent TechnologiesInstrumentation
GC/MSD, GC/MS/MS, GC/HRMS, GC/Q-TOF
Industries
Manufacturer
Agilent Technologies

Significance of the topic


Gas chromatography coupled with quadrupole time-of-flight mass spectrometry (GC/Q-TOF) provides unparalleled qualitative and quantitative capabilities. High mass resolution, accurate mass measurement, and MS/MS selectivity empower analysts to tackle challenging matrices at trace levels, reduce false positives, and streamline the identification of both target and unknown compounds.

Objectives and overview


The Agilent 7200 Q-TOF for GC/MS is the first Q-TOF system designed specifically to interface with gas chromatography. It integrates the separation performance of the 7890 Series GC with proven MS components from Agilent’s 7000 Triple Quadrupole GC/MS and 6500 LC/Q-TOF platforms. The system delivers robust operation, high-resolution full-spectrum acquisition, fast data rates, and accurate mass information for confident molecular characterization.

Methodology and instrumentation


  • Sample introduction: multimode inlet, backflush capability, low-thermal mass columns for rapid cycling
  • Ion source: programmable high-temperature extractor source and removable ion source for maintenance in about 30 minutes
  • Mass analyzer: hot quartz monolithic quadrupole, dual-stage ion mirror, proprietary INVAR flight tube for thermal stability
  • Detection: 4 GHz ADC electronics, dual gain amplifiers, hybrid channel plate detector with single-ion sensitivity
  • MS/MS: hexapole collision cell for fast, high-quality product ion spectra
  • Mass calibration: internal reference mass correction for sub-ppm stability
  • Vacuum system: multi-stage turbomolecular pumps for optimal pressure regions
  • Software: MassHunter Workstation and Mass Profiler Professional for acquisition, deconvolution, statistical analysis, and spectral library searching

Key results and discussion


  • Mass accuracy and resolution: ≤2 ppm mass error over 1–1000 pg on-column, with 15×–50× higher resolution than single quadrupole systems
  • Linearity and sensitivity: full-spectrum detection at low picogram levels, dynamic range up to 10^5 via dual gain amplifiers
  • Resolving power: FWHM ~13 500 resolved isobaric peaks differing by 0.0436 Da
  • Matrix interference removal: extraction windows down to ±0.010 Da allowed separation of analyte ions from coeluting components
  • MS/MS selectivity: accurate-mass product ion spectra for structural confirmation of targets and unknowns; examples include identification of a-cubebene and kava metabolites
  • Demonstrated applications across metabolomics (ergosterol pathway intermediates, fold-change analysis), food safety (pesticide screening, olive oil sensory model via PCA), environmental biomarkers in crude oil, and natural product research

Benefits and practical applications


  • Comprehensive qualitative and quantitative performance in a single run
  • Reduced false positives and improved confidence in compound identification
  • Rapid method development and automated data processing tools
  • Adaptable to diverse applications: food, environmental, pharmaceuticals, petrochemicals, metabolomics
  • Modular hardware and software for streamlined maintenance and high uptime

Future trends and potential applications


  • Integration of high-throughput deconvolution and machine learning for non-target screening
  • Expansion of accurate-mass MS/MS libraries and in silico fragmentation tools
  • Real-time monitoring and on-site GC/Q-TOF analysis for process control and environmental surveillance
  • Coupling with microfluidic sample preparation and automated reaction monitoring
  • Advanced chemometrics and network analysis in metabolomics and systems biology

Conclusion


The Agilent 7200 Q-TOF for GC/MS redefines gas-phase mass spectrometry by delivering high-resolution, accurate-mass, full-spectrum sensitivity, and MS/MS selectivity in a robust, user-friendly platform. Its versatile performance across multiple applications positions it as a powerful tool for modern analytical laboratories.

Reference


  • Analysis of Medium Volatility Sulfur Compounds in Coffee Using Agilent GC/Q-TOF; Pub. No. 5990-9076EN
  • Olive Oil Characterization using Agilent GC/Q-TOF MS and Mass Profiler Professional Software; Pub. No. 5991-0106EN
  • Analysis of Biomarkers in Crude Oil Using Agilent 7200 Q-TOF for GC/MS; Pub. No. 5990-9477EN

Content was automatically generated from an orignal PDF document using AI and may contain inaccuracies.

Downloadable PDF for viewing
 

Similar PDF

Agilent 7200B Series GC/Q-TOF
Agilent 7200B Series GC/Q-TOF
2014|Agilent Technologies|Brochures and specifications
Differential Analysis in Screening Assays for Extractable and Leachable Compounds
SCREENING OF COMPOUNDS
SCREENING OF COMPOUNDS
2014|Agilent Technologies|Others
7200 Series Q-TOF for GC/MS - A new analytical tool for solving complex analytical problems