Degradation of rotary vacuum pump oil determined by field desorption (FD) - TOFMS and group-type analysis software

Applications | 2007 | JEOLInstrumentation
GC/MSD, GC/TOF
Industries
Energy & Chemicals
Manufacturer
JEOL

Importance of the topic


The performance and longevity of vacuum pumps are highly dependent on the condition of their lubricating oil. Monitoring chemical changes in pump oil helps prevent system failures and contamination, supporting reliable industrial and research operations.

Objectives and study overview


This study aimed to compare the molecular composition of new and used rotary vane pump oil using field desorption time-of-flight mass spectrometry (FD-TOFMS). Group-type analysis software was applied to the mass spectra to quantify variations in hydrocarbon classes and infer degradation pathways.

Methodology and instrumentation


  • Sample materials: New and used rotary vane pump oil
  • Ionization technique: Positive field desorption (FD+)
  • Mass spectrometer: JMS-T100GC 'AccuTOF GC'
  • Cathode potential: -10 kV
  • Emitter current ramp: From 0 to 40 mA at 51.2 mA/min
  • Mass range: m/z 35–1600
  • Spectral acquisition interval: 0.5 s

Key results and discussion


FD mass spectra of both oils showed typical hydrocarbon distributions with subtle differences. Group-type analysis revealed that used oil exhibits:
  • Increased fractions of saturated (CnH2n+2) and moderately unsaturated species (CnH2n, CnH2n-2)
  • Decreased proportions of highly unsaturated hydrocarbons (CnH2n-4, CnH2n-6, CnH2n-8)
This suggests hydrogenation of multiple bonds, ring opening or oxidative degradation of unsaturated components. Apparent shifts in polymer distribution metrics (Mn, Mw, PD) further support progressive oil aging.

Benefits and practical applications


  • Soft ionization preserves intact molecular ions, enhancing molecular-level insights
  • Group-type analysis quantifies compositional shifts, enabling routine oil health monitoring
  • Early detection of degradation helps schedule preventive maintenance and avoid equipment downtime

Future trends and applications


  • Integration of high-resolution MS to resolve isobaric oxidation products
  • Automated data analysis pipelines for real-time oil condition assessment
  • Extension to diverse lubricant types and operational environments
  • Linking compositional data with predictive maintenance algorithms

Conclusion


Field desorption TOFMS combined with group-type analysis effectively discriminates new and used vacuum pump oil compositions. This approach provides a powerful tool for lubricant condition monitoring and supports improved maintenance strategies in industrial and analytical settings.

Content was automatically generated from an orignal PDF document using AI and may contain inaccuracies.

Downloadable PDF for viewing
 

Similar PDF

AccuTOF GC series Applications Notebook
AccuTOF GC series Applications Notebook
2016|Agilent Technologies|Applications
Group-type analysis of Crude Oil using GC/FI-TOFMS -  Reproducibility of group-type analysis results
Comprehensive 2D GC coupled with JEOL GC-HRTOFMS: GCxGC Applications
Group-type analysis of Crude Oil using GC/FI-TOFMS - Determination of average molecular weights by group-type analysis