Importance of the Topic


The demand for high-resolution, high-sensitivity liquid chromatography at nano- and micro-flow rates has grown with the advancement of proteomics, biopharmaceutical characterization, and QA/QC applications. The flexibility to tune flow rates from nano to analytical scales while maintaining retention time precision and system robustness is critical for in-depth analysis of complex samples and large-scale quantitative studies.

Objectives and Overview


This application note evaluates the versatility and performance of the Thermo Scientific UltiMate 3000 RSLCnano System. Key goals include demonstrating:
  • Precise flow control across 0.05–50 µL/min using ProFlow technology
  • Compatibility with micro, capillary, and nano workflows
  • Integration with mass spectrometers for high-confidence qualitative and quantitative analyses

Methodology


The system was assessed using:
  • Peptide digests (e.g., cytochrome C, HeLa cell lysate)
  • Varied column formats (75 µm × 150 mm to 75 µm × 750 mm, 2 µm particle size)
  • Gradient lengths from 30 to 240 min
  • Reproducibility studies over multiple days and replicates

Used Instrumentation


  • UltiMate 3000 RSLCnano System with ProFlow continuous-flow pump
  • WPS 3000 autosampler with µL pick-up injection and micro-fraction collection
  • Thermo Scientific nanoViper low-dead-volume connections and snap-in valves
  • Columns: Acclaim PepMap RSLC C18, ProSwift RP-10R, EASY-Spray
  • Detectors: UV/Vis variable wavelength for nano, capillary, micro flows
  • Mass spectrometers: Q Exactive HF, Orbitrap Fusion Lumos, TSQ Quantiva

Main Results and Discussion


  • Retention time precision: RSD < 0.20% over five days (12 injections per day) with 75 µm × 150 mm PepMap columns
  • Peak capacity up to ~900 using long nano columns (75 µm × 750 mm at 60 °C, 750 bar) and temperature control
  • Label-free quantification: >40,000 protein targets with <15% peak area RSD across seven replicates of HeLa digest (90 min gradient, 300 nL/min)
  • Proteome coverage: Identified up to 4,328 proteins in 90 min runs (1 µg load) with high inter-run consistency
  • Sensitivity gains: ~393-fold higher signal at nano flow (75 µm ID) compared to analytical flow (2.1 mm ID) for cytochrome C digest
  • Intact protein separation: Clear resolution of rituximab heavy and light chains via capillary RP chromatography with UV and MS detection
  • Targeted peptide quantification: Achieved 10 amol sensitivity and robust reproducibility at 4 µL/min using 0.3 × 50 mm PepMap and HESI-II probe

Benefits and Practical Applications


  • High retention time stability and reproducibility support large cohort quantitative studies
  • Flexible workflow configurations enable direct injection, pre-concentration, 2D separations, offline fractionation, and tandem LC
  • Robust integration with Thermo Scientific mass spectrometers via SII facilitates streamlined LC-MS/MS setups
  • Enhanced sensitivity allows detection of low-abundance analytes in proteomics and biopharmaceutical quality control

Future Trends and Possibilities for Use


The ongoing evolution of nano-UHPLC will focus on:
  • Further increasing system throughput through multiplexed columns and parallel analysers
  • Deeper integration with AI-driven method optimization and real-time data processing
  • Expanding multidimensional LC strategies to dissect complex proteomes and metabolomes
  • Improved nano-ESI interfaces for extended compatibility with emerging high-resolution MS platforms

Conclusion


The UltiMate 3000 RSLCnano System delivers exceptional versatility across flow regimes, superior retention time precision, and outstanding chromatographic efficiency. Its seamless integration with high-resolution mass spectrometers and robust operation make it a powerful solution for advanced proteomics, biopharmaceutical characterization, and targeted quantification.

References


  • Thermo Fisher Scientific. UltiMate 3000 RSLCnano System Application Note BR71898-EN. 2016.

Content was automatically generated from an orignal PDF document using AI and may contain inaccuracies.

Downloadable PDF for viewing
 

Similar PDF

Raise your nano LC-MS performance with new Thermo Scientific solutions
Thermo Scientific UltiMate 3000 RSLCnano UHPLC System - PRODUCT SPECIFICATIONS
Thermo Scientific UltiMate 3000 RSLCnano UHPLC System - PRODUCT SPECIFICATIONS
2018|Thermo Fisher Scientific|Brochures and specifications
High-throughput capillary-flow LC-MS proteomics with maximum MS utilization
Capillary-flow LC-MS: combining high sensitivity, robustness, and throughput