A Novel Benchtop Time-of-Flight GC-MS System for High Performance Analysis of Human Urine

Posters | 2016 | LECOInstrumentation
GC/MSD, GC/TOF
Industries
Metabolomics, Clinical Research
Manufacturer
Agilent Technologies, GERSTEL, LECO

Significance of the Topic


Urinary metabolite profiling is critical for understanding environmental exposure and its impact on chronic disease since urine is readily available and less complex in proteins and lipids than other biofluids

Objectives and Study Overview


This study aimed to develop a robust workflow combining chemical derivatization and high performance gas chromatography time of flight mass spectrometry to enable comprehensive comparison of derivatized urine samples from smokers and non smokers using standard reference materials

Methodology and Instrumentation


The workflow involved enzyme treatment of urine to remove urea followed by protein precipitation with methanol centrifugation and solvent evaporation Derivatization was achieved using MTBSTFA plus TBDMCS at elevated temperature A benchtop Pegasus BT GC TOFMS system was used equipped with an Agilent 7890 GC and MPS2 autosampler The analysis employed a 20 split ratio and a 12 minute acquisition time Data processing utilized NonTarget Deconvolution and a Target Analyte Finding method for rapid retrospective comparison of samples

Main Results and Discussion


Chromatograms revealed over thirty derivatized metabolites including amino acids organic acids fatty acids and xenobiotics The method achieved high spectral match scores often above 800 Library comparisons confirmed confident annotation of key analytes such as p cresol theobromine naproxen and santonox Quantitative analysis indicated elevated levels of several compounds in smokers urine relative to non smokers supporting its application in exposure assessment

Benefits and Practical Applications


  • Rapid high throughput profiling of urine metabolites
  • Comprehensive coverage of polar and non polar compounds
  • High confidence identification via accurate time of flight spectra
  • Retrospective data mining enables analysis of archived datasets

Future Trends and Possibilities


Integration with higher resolution mass spectrometry and automated data workflows will further enhance metabolome coverage Real time exposure monitoring and expanded use in clinical diagnostics and environmental biomonitoring are anticipated Machine learning based deconvolution could streamline annotation of complex mixtures

Conclusion


The presented benchtop TOF GC MS workflow delivers a fast reliable and validated approach for comprehensive metabolomic profiling of human urine Combining derivatization advanced instrumentation and powerful software offers a robust platform for exposure studies and biomarker discovery

References


  • Alonso D E Binkley J E Fell L M A Novel Benchtop Time of Flight GC MS System for High Performance Analysis of Human Urine Anal Bioanal Chem 2015 407 2945 2954

Content was automatically generated from an orignal PDF document using AI and may contain inaccuracies.

Downloadable PDF for viewing
 

Similar PDF

Analysis of Urine SRMs Using Solid Phase Micro Extraction, Dynamic Headspace and Liquid Injection with Comprehensive Two-Dimensional Gas Chromatography (GCxGC) High Resolution  Time-of-Flight Mass Spectrometry
Effects of Increased Fructose Consumption and Inadequate Copper Intake on the Pathogenesis of Nonalcoholic Fatty Liver Disease (NAFLD): A Feces, Plasma and Liver Metabolomics Study
Biomarker Identification in Nonalcoholic Fatty Liver Disease via GC/MS
Untargeted Investigation of Non-Alcoholic Fatty Liver Disease Using Effective Mutiplatform GC-MS Instrumentation