SPME, GC columns, Consumables, LC columns
IndustriesFood & Agriculture
ManufacturerMerck
Significance of Water Analysis
Water analysis is critical in food and beverage to ensure safety, monitor pollution, and comply with regulations. Contaminants such as disinfection by-products, volatile organics, microbial pathogens, metals, and additives can affect health and product quality.
Objectives and Overview
This document presents Sigma-Aldrich solutions for water testing from development to quality control. It covers certified reference materials, HS-SPME-GC-MS analysis of VOCs per ISO 17943, chromogenic media for Clostridium perfringens, headspace SPME method for MCHM, and UHPLC analysis of B vitamins.
Methodology and Instrumentation
- HS-SPME followed by GC-MS for headspace extraction and quantitation of > 60 VOCs.
- Interlaboratory validation of ISO 17943 with SPME conditions: DVB/CAR/PDMS fiber, 10 mL sample, 10 min at 40 °C.
- CP ChromoSelect Agar for selective detection of C. perfringens via chromogenic substrates.
- Headspace SPME-GC/MS-SIM extraction for MCHM and PPH in water.
- UHPLC on Titan C18 column (1.9 μm) with acidic aqueous/methanol gradient for rapid separation of nine water-soluble vitamins.
Used Instrumentation
- CTC Combi PAL autosampler.
- VOCOL GC columns (20 m × 0.18 mm, 1.0 μm).
- SPME fibers: DVB/CAR/PDMS, PDMS.
- Agilent 1290 UHPLC system with UV detection.
- GC-MS with EI source and SIM mode.
Main Results and Discussion
- ISO 17943: Recovery 84–118%, reproducibility < 35%, repeatability < 10%.
- C. perfringens: 96.9% specificity on CP ChromoSelect Agar; eliminates confirmation steps.
- MCHM detection: MDL 0.08 μg/L (isomer #1), 0.33 μg/L (isomer #2); PPH degrades in chlorinated matrices.
- UHPLC vitamins: separation in 2.5 min, peak resolution and retention optimized with Titan C18.
Benefits and Practical Applications
- Certified reference materials streamline method setup and ensure traceability.
- Automatable SPME methods reduce solvent use and increase throughput.
- Chromogenic media simplify microbial assays without additional confirmation.
- Fast UHPLC protocols support high-throughput vitamin analysis in fortified waters.
Future Trends and Possibilities
Further integration of automated extraction platforms, expansion of high-resolution mass spectrometry, development of multiplex assays for emerging contaminants, and on-site sensor technologies will enhance monitoring capabilities.
Conclusion
Sigma-Aldrich offers comprehensive consumables and reference materials to support safe and reliable water analysis across chemical and microbiological workflows.
References
- Arthur CL, Pawliszyn J. Anal Chem. 1990;62(19):2145–8.
- ISO 17943. Water Quality—Determination of Volatile Organic Compounds.
- ISO 5725-2. Accuracy of Measurement Methods.
- Koneman EW, et al. Color Atlas and Textbook of Diagnostic Microbiology. 5th ed. 1997.
- Sherris Medical Microbiology. 4th ed. McGraw Hill; 2004.
- 40 CFR Part 136. Method Detection Limit Procedure.
Content was automatically generated from an orignal PDF document using AI and may contain inaccuracies.