Structural Characterization of Cyclic Peptides using a Quadrupole Time-of-Flight Mass Spectrometer

Posters | 2019 | ShimadzuInstrumentation
LC/TOF, LC/HRMS, LC/MS, LC/MS/MS
Industries
Proteomics
Manufacturer
Shimadzu

Significance of the Topic


Cyclic peptides represent an emerging class of therapeutics with enhanced in vivo stability and cell permeability. Accurate structural characterization is essential for understanding their bioactivity and ensuring quality control during drug development.

Objectives and Study Overview


This work presents a comprehensive LC/Q-TOF MS method for the structural analysis of the cyclic peptide cyclosporin A. The goal was to achieve full sequence coverage and precise fragment assignment via high-resolution MS and MS/MS experiments.

Applied Methodology and Instrumentation


  • UHPLC system: Nexera X2 with Shim-pack GISS column (2.1×50 mm, 1.9 µm)
  • Mobile phases: 0.1 % formic acid in water (A) and in acetonitrile (B); gradient from 60 to 95 % B
  • Flow rate: 0.3 mL/min; column temperature: 50 °C; injection volume: 1 µL
  • Mass spectrometer: LCMS-9030 Q-TOF with >30 000 resolution (FWHM), <1 ppm mass accuracy, 100 Hz acquisition rate
  • Data analysis: ACD/MS Workbook Suite for formula prediction and fragment assignment

Main Results and Discussion


Accurate mass measurement confirmed [M+H]+ at m/z 1202.8486 and [M+2H]2+ at m/z 601.9279 within ±1 ppm. MS/MS spectra provided fragmentation along a, b, c, x, y, and z series, with mass errors below 1 mDa. The combined analysis achieved 100 % coverage of the cyclosporin A structure. Supplementary MS3 experiments on an IT-TOF system corroborated the MS/MS assignments.

Benefits and Practical Applications


The method enables rapid and reliable sequencing of cyclic peptides, facilitating drug discovery, metabolite profiling, and quality assurance workflows. High mass accuracy simplifies spectral interpretation and reduces manual verification.

Future Trends and Potential Applications


Emerging directions include integration with ion mobility for conformer separation, automated spectral annotation using advanced informatics, and extension of the workflow to other macrocyclic compounds and complex peptidomimetics.

Conclusion


The developed LC/Q-TOF MS approach delivers comprehensive structural insights into cyclosporin A using only high-resolution MS/MS data. It demonstrates a robust platform for the accurate sequencing of cyclic peptides in research and industrial settings.

References


Matsubara T, Inohana Y, Hirano I Structural Characterization of Cyclic Peptides using a Quadrupole Time-of-Flight Mass Spectrometer ASMS 2019 PO-CON1892E

Content was automatically generated from an orignal PDF document using AI and may contain inaccuracies.

Downloadable PDF for viewing
 

Similar PDF

Shimadzu Quadrupole Time-of-Flight Liquid Chromatograph Mass Spectrometer LCMS-9030
Shimadzu Quadrupole Time-of-Flight Liquid Chromatograph Mass Spectrometer LCMS-9030
Simplified approach for structural elucidation and quantitation for pharmaceutical API and related impurities
Characterizing Antibody-Drug Conjugates and Assigning Drug Conjugation Sites