NIR Spectroscopy
IndustriesEnergy & Chemicals
ManufacturerMetrohm
Determination of diethylene glycol, isophthalic acid, intrinsic viscosity and carboxyl end groups in PET by NIR — Application Note AN-NIR-023 (Summary)
Importance of the topic
The ability to monitor multiple quality attributes of polyethylene terephthalate (PET) quickly and without wet-chemical sample preparation is highly valuable for manufacturing and recycling operations. Conventional laboratory methods for intrinsic viscosity, diethylene glycol (DEG), isophthalic acid (IPA), and carboxyl end group (CEG) require dissolution, extraction or titration steps that are time-consuming, use reagents, and limit throughput. Near-infrared spectroscopy (NIRS) offers rapid, reagent-free, and potentially at-line screening to support process control, incoming material inspection and quality assurance for both virgin and recycled PET streams.
Objectives and overview of the study
This study evaluated whether an OMNIS NIR Analyzer Solid can simultaneously quantify key PET quality parameters — intrinsic viscosity (IV), diethylene glycol content, isophthalic acid content, and carboxyl end group concentration — in pelletized and flake PET without sample preparation. Data from virgin and mechanically recycled PET were used to build and validate chemometric prediction models and to compare predicted values against established laboratory reference methods.
Methodology and instrumentation
Key experimental facts and instrumental setup:
- Samples: 90 virgin PET pellet samples (wide ranges of IV, DEG, IPA, CEG); 50 recycled PET pellets; 200 recycled PET flakes.
- Spectrometer: OMNIS NIR Analyzer Solid, diffuse reflectance mode, spectral range ~1000–2250 nm.
- Sampling accessories: Large cup OMNIS NIR (100 mm) and large holder OMNIS NIR (100 mm); rotation and multipoint measurement were applied to compensate sample inhomogeneity in pellets and flakes.
- Software: OMNIS Software used for data acquisition and chemometric model development; Quant Development license and stand-alone options described.
- Reference laboratory methods used to build models: HPLC for isophthalic acid, extraction + HPLC-MS for diethylene glycol, viscometry (ASTM-style intrinsic viscosity determination) for IV, and titration for carboxyl end group.
- Measurement speed: NIR measurements acquired in seconds (typical instrument specification: solids/viscous samples measured in <10 s).
Main results and discussion
Overview of predictive model performance (model statistics as reported):
- Intrinsic viscosity — virgin PET pellets: correlation coefficient R2 = 0.868; standard error of calibration/validation reported as SEC = 1.70 dL/g and SECV = 1.75 dL/g (model shows useful quantitative correlation though with modest precision versus lab viscometry).
- Isophthalic acid — virgin PET pellets: R2 = 0.993; SEC ≈ 0.06% and SECV ≈ 0.07% (very strong model performance consistent with robust HPLC-based reference).
- Diethylene glycol — virgin PET pellets: R2 = 0.925; SEC ≈ 0.04% and SECV ≈ 0.04% (high correlation to the HPLC-MS reference; suitable for rapid screening and quantification).
- Carboxyl end group — virgin PET pellets: R2 = 0.852; SEC = 2.91 meq/kg and SECV = 3.30 meq/kg (acceptable correlation for routine QC where trend detection and batch screening are primary goals).
- Intrinsic viscosity — recycled PET pellets: R2 = 0.881; SEC = 0.0070 dL/g and SECV = 0.0079 dL/g (good predictive accuracy for recycled pellet material).
- Intrinsic viscosity — recycled PET flakes: R2 = 0.905; SEC = 0.0088 dL/g and SECV = 0.0102 dL/g (model performs slightly better for flakes in terms of correlation).
Additional observations:
- NIR spectra from virgin pellets, recycled pellets and flakes show reproducible features that enable differentiation and quantification of the listed parameters when combined with chemometric calibration.
- Rotation and multi-point sampling are critical to minimize the influence of sample heterogeneity in granules and flakes, improving model robustness.
- Prediction quality varies by parameter: chemical constituents present in larger spectral signatures (IPA, DEG) provided the strongest models, while structural or end-group metrics (IV, CEG) produced useful but less precise predictions compared to their wet-chemical counterparts.
Benefits and practical applications
Practical advantages demonstrated by the NIR approach in this study include:
- Speed: result per sample in seconds versus tens of minutes to hours for lab methods. Representative laboratory time-to-result comparisons reported were: DEG and IPA via preparation + HPLC ~45 min preparation + 40 min run; intrinsic viscosity dissolution ~90 min preparation + 1 min viscometry; CEG dissolution and titration ~90 min + 10 min. NIR eliminates most preparation times.
- No chemical reagents or solvent consumption, reducing consumables cost and lab waste generation.
- Simultaneous multiparameter output from a single measurement enables high-throughput screening and at/near-line deployment in production or recycling facilities.
- Compatibility with pellets and flakes supports quality control across different material formats encountered in virgin and recycled PET processing.
Instrumentation used
Components and features used in the study and relevant for implementation:
- OMNIS NIR Analyzer Solid — near-infrared spectrometer for solids and viscous samples (1000–2250 nm); rapid measurements (<10 s) and automated multi-position sampling capability.
- Large cup OMNIS NIR, 100 mm — sample vessel for powders and granulates with a durable glass bottom (Gorilla Glass); supports rotation and multipoint reflectance measurements.
- Large holder OMNIS NIR, 100 mm — ensures reproducible positioning and rotation of the sample vessel.
- OMNIS Software with Quant Development license — for data acquisition and calibration/model development; stand-alone license options described for independent workstation deployment.
Future trends and potential applications
Potential developments and applications building on this work include:
- Expanded calibration sets to increase model robustness across broader feedstock variability (different recyclate sources, contaminants, colorants, polymer copolymers).
- Inline or at-line integration for real-time process control within polymerization, pelletizing or recycling lines, enabling closed-loop adjustments based on IV or additive content.
- Hybrid approaches combining NIR screening with targeted confirmatory lab analyses to optimize resource use — e.g., flagging out-of-spec batches for full laboratory testing.
- Advanced chemometric strategies (e.g., transfer learning, domain adaptation) to simplify model transfer between instruments, sites and sample presentations.
- Use in certification and sorting workflows for recycled PET to support circular economy targets by rapidly characterizing material quality before remelting or repolymerization.
Conclusion
The application note demonstrates that NIR spectroscopy using the OMNIS NIR Analyzer Solid can provide rapid, reagent-free, simultaneous predictions of several key PET quality parameters in both virgin and recycled materials. Prediction strengths vary by analyte: IPA and DEG models achieved very high correlation to HPLC-based references, while IV and CEG models delivered useful screening performance. The primary operational advantage is time-to-result and the potential for integration into production or recycling workflows, enabling higher throughput QC and reduced reliance on multiple slow wet-chemical assays.
References
- Metrohm AG, Application Note AN-NIR-023: Determination of diethylene glycol, isophthalic acid, intrinsic viscosity and carboxyl end group in PET with NIRS (OMNIS NIR Analyzer Solid). Application Note provided by Metrohm; experimental data and model performance as reported in the note.