LC/MS, LC/MS/MS, LC/IT
IndustriesPharma & Biopharma
ManufacturerWaters
Analytical Repeatability and Precision of the Xevo CDMS System for AAV Capsid Characterization — Summary
Significance of the topic:
- Accurate characterization of adeno-associated virus (AAV) capsid populations (Empty, Partially filled, Full, Overfilled) is essential for gene-therapy product quality, process development, and regulatory assessment. Variability in capsid composition can affect delivered genome dose, immunogenic risk, and lot comparability; therefore, analytical methods that deliver reproducible, population-level mass and abundance data are critical.
Objectives and study overview:
- Evaluate the analytical repeatability, intermediate precision, and operational robustness of the Xevo Charged Detection Mass Spectrometry (CDMS) System for intact AAV8 capsid analysis.
- Perform two complementary studies: (1) multi-day repeatability using 12 replicate injections per day over five consecutive days of a 1:1 Empty:Full AAV8 mixture at 1 × 10^13 vp/mL, and (2) concentration-repeatability by alternating injections of the same 1:1 mixture diluted to upstream- and downstream-equivalent concentrations (1 × 10^11 and 5 × 10^12 vp/mL) to assess performance across a 50-fold concentration range and varying injection order.
Methodology and used instrumentation:
- Samples: Commercial AAV8 CMV-GFP Empty and Full capsids; vendor-determined titers (qPCR or ELISA). Buffer exchange into 200 mM ammonium acetate with 0.01% Pluronic F-68 using Bio-Spin P-6 size-exclusion columns.
- Instrumentation: Xevo CDMS System employing an electrostatic linear ion trap (ELIT) to measure individual ions' m/z via oscillation frequency and charge via induced signal magnitude; positive-mode nano-electrospray ionization (nESI) for ion generation.
- Acquisition parameters: ions trapped for 100 ms; typical acquisition ~25 minutes targeting ~5,000 single-ion events per measurement.
- Data processing: Time-domain signals transformed (FT) to extract oscillation frequencies and signal magnitudes; generation of m/z, charge, and mass histograms and 2D heat maps using waters_connect software and the waters_connect CDMS Toolkit. Relative abundances were calculated from counts within defined mass-population windows.
Main results and discussion:
- Multi-day repeatability: Across 60 planned measurements (12 injections × 5 days) of the 1:1 Empty/Full mixture at 1 × 10^13 vp/mL, relative peak abundances remained highly consistent. Reported variability was <2% RSD for relative capsid populations, with individual injections within ±3% of the mean. Normalized mass distributions from daily averages showed strong overlap, indicating reproducible mass-resolved population profiles over time.
- Concentration-repeatability: Alternating injections between low (1 × 10^11 vp/mL) and high (5 × 10^12 vp/mL) concentrations demonstrated reproducible relative quantification across a 50-fold concentration change and varying injection order. Reported RSD for Empty/Partial, Full, and Overfull species was ≤5% across these conditions.
- Operational robustness: The system sustained consistent analytical performance across extended sessions, supporting reliable direct-infusion workflows for intact AAV characterization.
Benefits and practical applications of the method:
- Direct single-particle mass measurement enables clear differentiation of Empty, Partially filled, Full, and Overfilled AAV capsids without deconvolution of ensemble charge-state distributions.
- Demonstrated low analytical variability supports informed process decisions by distinguishing true process-induced changes from measurement noise—useful for upstream/downstream development, lot release, and comparability studies.
- Robust performance across process-relevant concentrations facilitates analysis of samples from multiple manufacturing stages without extensive sample normalization.
- Data produced by CDMS can complement orthogonal assays (qPCR, ELISA, AUC, TEM) to build a comprehensive quality assessment package for regulatory submissions.
Future trends and potential applications:
- Integration with process analytical technology (PAT) pipelines and increased automation for higher throughput and in-line monitoring of vector production.
- Improvements in absolute quantitation and calibration strategies for CDMS to enable more direct estimation of particle counts and genome copy numbers per capsid.
- Enhanced data analytics, including machine learning, for automated population deconvolution, anomaly detection, and predictive QC metrics across manufacturing lots and serotypes.
- Expansion of CDMS to analyze broader classes of viral vectors and large biomolecular assemblies, coupled with standardized reference materials and regulatory harmonization to facilitate acceptance in GMP environments.
Conclusion:
- The Xevo CDMS System provided reproducible, high-precision relative quantification of AAV8 capsid populations across repeated injections, multiple days, and a 50-fold concentration range. Measured RSDs were <2% for the five-day study and ≤5% when alternating concentration injections, supporting the system's suitability for AAV process development, comparability testing, and product characterization workflows.
References:
- Destro F.; et al. The State of Technological Advancement to Address Challenges in the Manufacture of Raav Gene Therapies. Biotechnology Advances. 2024;76:108433.
- Sripada S. A.; et al. Advances and Opportunities in Process Analytical Technologies for Viral Vector Manufacturing. Biotechnology Advances. 2024;74:108391.
- Ujma J.; et al. A Charge Detection Mass Spectrometer for the Analysis of Megadalton-Sized Molecules. bioRxiv. 2026.
- Protein Data Bank entry used for structural reference: PDB 2QA0.
Content was automatically generated from an orignal PDF document using AI and may contain inaccuracies.