Fast on-line monitoring of fuel gases Prima PRO Process Mass Spectrometer

Applications | 2025 | Thermo Fisher ScientificInstrumentation
GC/MSD
Industries
Energy & Chemicals
Manufacturer
Thermo Fisher Scientific

Importance of the topic


Fuel gases with variable composition are common in petrochemical plants, steel works and other industrial sites. Small changes in minor components can substantially alter heating value, density and combustion behaviour, leading to inefficient fuel use, increased emissions, temperature control problems and even component damage. Rapid, comprehensive on-line compositional analysis is therefore essential to enable feed‑forward control of combustion air and fuel flow, optimize energy usage, reduce waste and protect product quality.

Objectives and study overview


This application note presents the capabilities and performance of the Prima PRO Process Mass Spectrometer for fast, on‑line monitoring of fuel gases. The primary goals are to demonstrate (1) rapid, multi‑component compositional analysis; (2) derivation of combustion properties (calorific value, Wobbe index, stoichiometric air requirement, CARI, density, specific gravity); (3) multistream sampling for many process lines; and (4) long‑term precision and stability in industrial conditions, including independent evaluation against industry standards.

Methodology


Process mass spectrometry (MS) ionises gas constituents and separates ions by mass/charge to determine mole fractions of components. From measured composition, derived properties are computed by mole‑fraction weighted sums (e.g., calorific values, density) and combined metrics such as Wobbe Index and CARI that account for density effects on flow through restrictions. The Prima PRO system uses a scanning magnetic sector analyser for high precision and linearity. Analysis cycles including stream switching are typically under 30 seconds; typical analytical precision is better than 0.1% relative (or ~0.01 mol% absolute) for many components.

Used Instrumentation


  • Thermo Scientific Prima PRO 710 magnetic sector process mass spectrometer (scanning laminated magnet with magnetic flux feedback for 24‑bit mass alignment).
  • Rapid Multistream Sampler (RMS) with 32 or 64 selectable sample ports, optically encoded position sensing, software controlled stream selection and user‑configurable settling times. RMS can be heated to 120 °C and provides per‑stream digital flow recording and alarm capability for loss of sample flow.
  • Thermo Scientific GasWorks software for method management; support for unlimited analysis methods and per‑stream method optimization.
  • Plant communications: analog outputs (4–20 mA, 0–10 V), Modbus, Profibus, OPC.

Main results and discussion


Independent testing: EffecTech (UK) performed an independent evaluation under ISO 10723/ISO/IEC 17025 conditions using nine gravimetrically prepared reference gases spanning a wide dynamic range of typical fuel‑gas components (H2, CO, N2, CO2, CH4, C2–C3 hydrocarbons, etc.). The Prima PRO was calibrated with a single mixture and demonstrated excellent linearity across the tested concentration ranges, outperforming a thermal conductivity detector in linearity for complex mixtures.

Precision and stability: The magnetic sector analyser produces flat‑topped peaks leading to inherently stable responses. Typical calibration intervals are around one month and may be automated. Example data show 24‑hour reproducibility of derived calorific values with relative standard deviations well below 0.1% for many components; a 30‑day run on a 13‑component hydrocarbon blend exhibited average RSDs generally below 1% for individual constituents, indicating robust long‑term stability without frequent recalibration.

Analysis speed and flexibility: Scanning speeds comparable to quadrupole systems combine with sector‑level stability, allowing rapid analysis of an unlimited number of user‑defined gas mixtures. Per‑stream method selection enables optimizing the trade‑off between speed and precision for each sample line; additional components can be added to methods when feed composition changes (e.g., monitoring heavier hydrocarbons or trace species like H2S, NH3, naphthalene).

Comparison with alternative approaches: Calorimeters and discrete oxygen or density meters have been used historically, but they cannot simultaneously provide full composition, fast response and derived combustion indices. Calorimeters are typically slower (~2.5 minutes) and less precise (~1% relative) than Prima PRO, and they cannot directly yield stoichiometric air requirement or detailed composition needed for environmental or process control decisions.

Benefits and practical applications


  • Fast feed‑forward control of combustion air and fuel flow to maintain furnace temperature and product quality.
  • Reduced fuel consumption and lower operating costs through precise control of air/fuel ratios and timely detection of composition shifts.
  • Extended burner life and reduced risk of damage by avoiding over‑ or under‑airing.
  • Improved environmental monitoring by quantifying trace or hazardous components (H2S, NH3, aromatics).
  • Centralized multi‑stream monitoring (up to 64 streams) with per‑stream methods and automated alarms for sample flow loss.

Future trends and potential applications


Process mass spectrometry is likely to expand its role in industrial combustion control and energy optimization as plants pursue carbon reduction and efficiency targets. Expected developments include tighter integration with plant control systems for automated feed‑forward adjustments, wider adoption of multistream sampling in large complexes, advanced software analytics for predictive maintenance and optimization, and improved trace detection for emissions compliance. Combining MS data with real‑time process models and digital twins can amplify gains in energy efficiency and product quality.

Conclusion


The Prima PRO Process Mass Spectrometer delivers rapid, precise and comprehensive on‑line analysis of fuel gases, enabling accurate derivation of calorific value, Wobbe index, density, stoichiometric air requirement and CARI. Its magnetic sector design, rapid multistream sampling and demonstrated long‑term stability make it well suited for industrial environments where multiple, variable fuel streams must be controlled for efficiency, safety and product quality.

References


  1. ISO 6976:2016. Calculation of calorific values, density, relative density and Wobbe indices from composition.
  2. ISO 10723:2012. Natural gas - Performance evaluation for analytical systems.
  3. Wright R. 2004. Mass spectrometry: gas analysis. In P.J. Worsfold, A. Townshend and C. Poole (eds.), Encyclopaedia of Analytical Science, 2nd ed., Vol. 5, pp. 493–501, Elsevier.

Content was automatically generated from an orignal PDF document using AI and may contain inaccuracies.

Downloadable PDF for viewing
 

Similar PDF

Fast on-line monitoring of fuel gases
Fast on-line monitoring of fuel gases
2025|Thermo Fisher Scientific|Applications
Fast on-line monitoring of flare gases
Fast on-line monitoring of flare gases
2025|Thermo Fisher Scientific|Others
Maintain Compliance to Petrochemical (EMACT) and Organic Chemical Sector (MON) Flare Gas Rules with Rapid Online Analysis by Prima PRO Mass Spectrometers
Accurate multi-component blast furnace gas analysis maximizes iron production and minimizes coke consumption