Significance of the topic

Advances in untargeted metabolomics hinge on robust, integrated data-processing workflows that combine feature detection, alignment, statistical evaluation and compound annotation. Streamlined, end-to-end processing reduces fragmentation between tools, improves reproducibility for large cohorts and accelerates biomarker discovery in clinical studies such as those targeting pancreatic ductal adenocarcinoma (PDAC).

Objectives and study overview

This study demonstrates the application of LabSolutions Insight Profiler, a single-software workflow for untargeted LC/QTOF metabolomics. The objectives were to (1) automate feature detection, alignment, filtering and statistical analysis within one processing method, (2) perform compound identification against multiple spectral libraries, and (3) apply the workflow to serum samples from PDAC patients versus healthy controls to identify candidate biomarkers.

Methods and experimental design

The investigation analysed serum from 30 PDAC patients and 30 healthy controls. Samples were extracted in methanol (1:3 v/v). For LC/QTOF analysis samples were diluted 1:10 for positive-ion acquisition and 1:2 for negative-ion acquisition. A pooled quality-control (QC) sample (combined aliquots of all study samples) was used to condition the system and injected periodically (every six injections) to monitor analytical performance and to support filtering of high-variance features.

Key data-processing parameters applied within LabSolutions Insight Profiler included a minimum peak height of 1000 and a summed ion signal threshold of 10,000 counts per chromatographic peak. Alignment tolerances were 10 mDa (mass) and 0.1 min (retention time). Features with QC relative standard deviation (RSD) >20% were removed. Only features present in at least 75% of samples in at least one biological group were retained. Missing values were imputed as one-fifth of the minimum observed value for the feature. Statistical thresholds were set to fold change ≥2 and p < 0.05 (two-group comparisons using t-tests computed by the software).

Used instrumentation

  • UHPLC: Nexera X2 with C18 column (2.1 × 100 mm, 1.7 µm). Column oven 50 °C, flow 0.4 mL/min. Mobile phases: A = water + 0.1% formic acid; B = acetonitrile + 0.1% formic acid. Gradient optimized for broad metabolome coverage with total run ~35 min. Autosampler at 4 °C, injection volume 0.5 µL. Rinse solvents: IPA/MeOH/MeCN/H2O (1:1:1:1) + 1% formic acid.
  • MS: Shimadzu LCMS-9030 quadrupole time-of-flight (QTOF) operated in data-independent acquisition (DIA) mode. ESI voltages: +1.5 kV (positive) and -3.0 kV (negative). Interface/heat/DL block temps: 300 °C / 400 °C / 250 °C. Gas flows: nebulizing 3 L/min, heating 10 L/min, drying 15 L/min. CID gas pressure ~230 kPa.
  • Acquisition settings: TOF-MS m/z 60–1000; DIA MS/MS m/z 40–1000 using 27 events with precursor isolation windows ~35 Da and collision energy spread 5–55 V. Total cycle time (MS + MS/MS) ~1 s.
  • Software: LabSolutions for instrument control and LabSolutions Insight Profiler for automated feature detection, alignment, filtering, statistical analysis and library searching.

Data processing workflow (LabSolutions Insight Profiler)

The software integrates feature detection and alignment with downstream multivariate and univariate statistics and automated library searching against multiple MS/MS databases (Shimadzu in-house libraries, LipidBlast, HMDB, NIST, MassBank, MoNA). Users configure a single processing method (batch) that executes all steps and produces linked visualizations: chromatograms, spectra, PCA and volcano plots, boxplots and tables. Library matches are ranked by similarity index (SI); candidate identifications from third-party libraries require manual review to meet reporting confidence guidelines (Metabolomics Standards Initiative levels).

Main results and discussion

The workflow detected statistically significant metabolic differences between PDAC and control serum. Notable findings include reductions in linoleic-acid–containing phospholipids (for example LPC 18:2, PC 18:1_18:2, PC 18:2_18:2, PC 18:2_20:4) and decreases in several lysophosphatidylcholines and lysophosphatidylethanolamines (LPE 18:2, LPC 18:1, LPC 18:3, LPC 20:5). Conversely, glutamic acid was elevated in PDAC serum and confirmed to MSI level 1 using an authentic standard. Lipid annotations were mostly assigned at MSI level 2 based on MS/MS matching to LipidBlast and were cross-validated by confirming corresponding features in both ionization modes. Visualization and linked tables allowed rapid inspection of features, spectra and statistical context to prioritize candidates for follow-up.

This case study illustrates that a single configurable processing cascade can produce robust, reproducible results for untargeted biomarker discovery while enabling rapid manual review of library hits to ensure annotation quality.

Benefits and practical applications

  • Integrated workflow reduces transfer of data between tools, decreasing analyst time and potential for errors.
  • Batchable, single-method processing improves reproducibility across large cohorts and facilitates routine untargeted studies.
  • Linked visualization (chromatogram, spectrum, PCA, volcano and boxplots) accelerates interpretation and candidate selection for validation.
  • Support for multiple MS/MS libraries and both ionization modes increases annotation confidence and throughput for lipidomics and broader metabolomics applications.
  • QC-driven filtering (pooled QCs, RSD thresholds, presence criteria) enforces analytical quality control recommended for untargeted metabolomics.

Future trends and potential applications

  • Greater automation and standardization across platforms will be needed to scale biomarker discovery to multi-site clinical studies and regulatory contexts.
  • Improved spectral libraries and curated in-house databases, plus machine-learning–assisted annotation, will increase MSI level 2→1 confirmations and reduce false positives.
  • Integrating retention-time prediction, ion mobility and orthogonal fragmentation information will strengthen identification confidence for isomeric lipids and polar metabolites.
  • Harmonized QC metrics and automated reporting will aid compliance with community recommendations for analytical quality management in untargeted metabolomics.
  • Expanded support for cloud-based batch processing and provenance tracking will help reproducibility and collaborative research across institutions.

Conclusion

LabSolutions Insight Profiler provides a practical, single-application solution for untargeted LC/QTOF metabolomics by automating feature detection, alignment, statistical analysis and library-based identification within one processing method. Applied to PDAC versus control serum, the workflow identified biologically plausible lipid alterations and confirmed at least one metabolite to MSI level 1. The approach simplifies complex data-processing pipelines while preserving analytical rigour, enabling faster turnaround for biomarker discovery and exploratory metabolomics studies.

References

1. Kirwan JA, Gika H, Beger RD, et al. Quality assurance and quality control reporting in untargeted metabolic phenotyping: mQACC recommendations for analytical quality management. Metabolomics. 2022;18(9).
2. Theodoridis G, Fiehn O, Holčapek M, et al. What’s in a name? Metabolite identification: challenges and pitfalls in untargeted metabolomics. Metabolomics. 2026;22(22).
3. Wolrab D, Jirásko R, Cífková E, et al. Lipidomic profiling of human serum enables detection of pancreatic cancer. Nature Communications. 2022;13:124.
4. Spicer R, Salek R, Steinbeck C. A decade after the metabolomics standards initiative it's time for a revision. Scientific Data. 2017;4:170138.

Content was automatically generated from an orignal PDF document using AI and may contain inaccuracies.

Downloadable PDF for viewing
 

Similar PDF

Untargeted Metabolomics Analysis of Pancreatic Cancer Using LC/QTOF
Metabolite profiling applied to biomarker discovery in pancreatic cancer using high resolution LC-MS/MS
Insight Profiler streamlines analysis of non-targeted metabolomics data from LCMS or direct injection in a single software solution
Oxygen Attachment Dissociation for the Structural Characterisation of Lipids Involved in Pancreatic Cancer