Analysis of Fluorine by EDXRF —A Simple Check for PFAS in Electrical and Electronic Components

Applications | 2026 | ShimadzuInstrumentation
X-ray
Industries
Materials Testing, Semiconductor Analysis
Manufacturer
Shimadzu

Importance of the topic


Rapid and reliable screening for fluorine and other halogens in electrical and electronic (E&E) materials is increasingly important due to tightening regulations on PFAS and halogenated flame retardants. Early detection of elemental fluorine, chlorine and bromine in components aids supply-chain compliance, helps prioritize samples for confirmatory analysis, and reduces time and cost compared with full chemical-speciation workflows.

Objectives and study overview


This application note demonstrates the use of an energy dispersive X-ray fluorescence spectrometer (EDX-8100) for quick detection and semi-quantitative analysis of halogens in representative E&E samples. Two example samples were analyzed: an ETFE-coated wire and a relay. The goal was to show that EDXRF can detect fluorine and other halogens on surfaces with minimal sample preparation and provide screening-level results useful for compliance filtering and sample triage.

Used instrumentation


Ultravacuum energy dispersive X-ray fluorescence spectrometer: EDX-8100 (Shimadzu).
  • X-ray tube: Rhodium (Rh) target.
  • Detector: silicon drift detector (SDD).
  • Atmosphere: vacuum measurement for improved halogen sensitivity.
  • Measurement channels: Ti–U channel and C–Sc channel (C–Sc channel used for fluorine detection).
  • Collimator: 10 mm diameter.
  • Typical integration times: 20 s for Ti–U channel, 60 s for C–Sc channel (fluorine).
  • Quantification approach: Fundamental Parameters (FP) method; organic fraction in composite samples represented by a surrogate formula where applicable.

Methodology


Samples were measured directly without chemical preparation: the ETFE-coated wire bundle and the relay were simply placed under the instrument camera and analyzed. Qualitative elemental spectra were first inspected to locate halogen peaks. Quantification used the FP method with assumed compositions for organic fractions when necessary (for example, ETFE represented as C4H4F4 or a C12-based surrogate for residual organic mass in composite samples). Measurements used vacuum conditions and the SDD detector to maximize sensitivity to low-Z halogens, with short total measurement times (minutes), enabling rapid throughput.

Main results and discussion


ETFE-coated wire:
  • Strong fluorine signal consistent with the ETFE coating was observed. Quantification treating the organic fraction as C4H4F4 produced an estimated polymer fraction of ~95 wt% in the probed surface/near-surface volume (reference value for the composite sample).
  • Metallic elements (Cu, Sn) from the underlying conductor were also detected; this highlights that measurements on composite or layered samples reflect a mix of surface coating and substrate contributions and should be interpreted as reference values.

Relay (electrical component):
  • Fluorine (~0.35 wt%), bromine (~1.93 wt%) and antimony (~1.23 wt%) were detected on the relay surface in this example, suggesting the presence of fluorinated materials (e.g., release agents, coatings, or anti-drip additives), brominated flame retardants, and antimony-based synergists.
  • Other elements such as Ca, Si, Cu, Fe, Ni and trace metals were also identified, reflecting composite construction and internal components. Quantified concentrations for composite parts are therefore approximate and serve screening purposes only.

Sensitivity and limitations:
  • Fluorine was reliably detected and quantified when its content was on the order of ~0.1 wt% or higher under the shown measurement conditions.
  • EDXRF provides elemental information only — it cannot identify molecular species or distinguish specific PFAS compounds.
  • Surface sensitivity and contributions from underlying materials can bias apparent concentrations in composite samples; detected metal signals indicate substrate influence in some measurements.

Benefits and practical applications


  • Minimal or no sample preparation accelerates throughput for supply-chain screening and incoming inspection.
  • Simultaneous multi-halogen detection (F, Cl, Br, I) allows quick assessment for both fluorinated materials and halogenated flame retardants in a single measurement.
  • Short measurement times (tens of seconds to a few minutes) enable rapid triage of many samples to prioritize those requiring confirmatory, compound-specific analyses (e.g., targeted MS or chromatographic methods).
  • Non-destructive surface analysis is useful for finished parts and assemblies where destructive sampling is undesirable.

Future trends and possibilities for use


  • Regulatory pressure on PFAS and halogenated flame retardants will increase demand for rapid, high-throughput screening tools across electronics manufacturing and supply chains.
  • Advances in detector technology, vacuum handling and FP algorithms will further lower detection limits for light halogens and improve quantification accuracy for thin coatings and small features.
  • Combining EDXRF screening with surface-mapping capability, portable XRF for field checks, and automated data pipelines (QC dashboards, compliance traceability) will streamline materials management and regulatory reporting.
  • EDXRF should be integrated into tiered testing strategies where positive or borderline results trigger targeted follow-up by speciation-capable techniques to identify specific PFAS or flame-retardant molecules.

Conclusion


EDXRF using the EDX-8100 provides a rapid, low-preparation approach to detect fluorine and other halogens on E&E components. Detection of fluorine near or above ~0.1 wt% is feasible under vacuum SDD conditions with short integration times, making EDXRF an effective first-line screening tool for PFAS-related and halogenated flame-retardant assessments. Results are screening-level and should be followed by confirmatory, compound-specific analyses when regulatory compliance or detailed speciation is required.

References


  1. European Chemicals Agency (ECHA). Submitted restrictions under consideration; ECHA publications related to PFAS and sector evaluation.
  2. ECHA PACT RAC sector evaluation: Electronics and Semiconductors.
  3. Washington State Legislature. Chapter 173-337 WAC: Safer Restrictions and Reporting (Safer Products for Washington).
  4. Washington State Department of Ecology. Resource for Complying with the Safer Products for Washington Rule: Electric and Electronic Products.

Content was automatically generated from an orignal PDF document using AI and may contain inaccuracies.

Downloadable PDF for viewing
 

Similar PDF

Analysis of Fluorine by EDXRF: Simple Check for Use of PFAS for Textile and Kitchen Supplies
Quantitative Analysis of Fluorine by EDXRF: Powder and Fluorine-Containing Fil
Shimadzu EDX-LE
Shimadzu EDX-LE
2017|Shimadzu|Brochures and specifications
Analysis of Recycled Materials by EDXRF
Analysis of Recycled Materials by EDXRF
2025|Shimadzu|Applications