HPLC, Consumables, LC columns
IndustriesPharma & Biopharma
ManufacturerShimadzu
Importance of the Topic
The characterization of therapeutic antibodies by charge variant analysis is critical for ensuring product consistency, safety and efficacy. Subtle differences in post-translational modifications such as deamidation or glycation can produce acidic or basic species, impacting biological activity, stability and regulatory compliance. A robust, high-resolution method for infliximab charge profiling supports quality control in biopharmaceutical manufacturing.
Objectives and Study Overview
This application note evaluates a pH-gradient ion-exchange chromatography method on a Shim-pack Bio IEX SP-NP column for separating infliximab charge variants. The study compares the performance of the Shim-pack column to a competitor’s stationary phase, focusing on resolution, peak shape and throughput under a defined pH gradient.
Methodology and Instrumentation
System configuration and analytical conditions:
- Instrument: Nexera™ lite inert high-performance liquid chromatograph
- Column: Shim-pack Bio IEX SP-NP, 100 mm × 4.6 mm I.D., 5 µm particles
- Mobile phases: A (30 mmol/L MES-HEPES-sodium acetate, pH 5), B (same buffer at pH 10)
- Gradient: 20 % B at 0 min → 100 % B over 11–13.5 min → 20 % B to 18.5 min
- Flow rate: 1.0 mL/min; Column temp.: 30 °C; Injection: 10 µL; Detection: UV 280 nm
Main Results and Discussion
The Shim-pack Bio IEX SP-NP column delivered sharper peaks and improved separation of acidic, main and basic infliximab variants compared to the competitor’s column. Baseline resolution was achieved within an 18.5-minute run, demonstrating superior selectivity of the stationary phase. Peak capacities were higher, enabling reliable quantitation of low-abundance species.
Benefits and Practical Applications
- Enhanced resolution accelerates method development and shortens analysis time.
- pH-gradient elution provides broad applicability to other mAbs with varying isoelectric points.
- Reproducible performance supports routine quality control and stability studies.
Future Trends and Potential Applications
Advances in mixed-mode and monolithic stationary phases may further reduce analysis time and increase robustness. Integration with mass spectrometry detection can yield detailed structural insights into charge variants. Automated high-throughput platforms will support bioprocess monitoring and comparability studies in biosimilar development.
Conclusion
The pH-gradient IEX method on Shim-pack Bio IEX SP-NP provides an efficient, high-resolution approach for infliximab charge variant analysis. Its superior selectivity and reproducibility make it a valuable tool for biopharmaceutical quality control.
Reference
Shimadzu Corporation. pH Gradient Analysis of Infliximab Charge Variants on Shim-pack Bio IEX SP-NP. Application Note ERAS-1000-0603. First Edition: Sep. 2025.
Content was automatically generated from an orignal PDF document using AI and may contain inaccuracies.