Simultaneous Analysis of beer components

Applications | 2023 | ShimadzuInstrumentation
HPLC, Consumables, LC columns
Industries
Food & Agriculture
Manufacturer
Shimadzu

Simultaneous Analysis of Beer Bitter Compounds Using Shim-pack Velox Biphenyl Column



Significance of the Topic


Beer bitterness is a key quality attribute that influences consumer acceptance and product consistency. Quantification of hop-derived compounds such as α-acids, β-acids, iso-α-acids, humulinones, xanthohumol and isoxanthohumol is crucial for flavor profiling, stability studies and functional ingredient research in the brewing and food industries.

Study Objectives and Overview


This application note demonstrates a robust reversed-phase liquid chromatography method for the simultaneous separation and quantification of six bitter-taste and bioactive components in beer. The approach targets rapid analysis, high selectivity and reproducibility for routine quality control and research applications.

Methodology and Instrumentation


The analysis was performed on a Shimadzu i-Series LC-2050C 3D system equipped with a Shim-pack Velox Biphenyl column (100 mm × 3.0 mm I.D., 2.7 µm). Mobile phase A comprised 10 mmol/L sodium phosphate buffer (pH 2.6) with 0.2 mmol/L EDTA, and mobile phase B was acetonitrile. The gradient elution at 0.7 mL/min and column temperature of 40 °C achieved baseline separation in under 30 minutes. A 20 µL injection volume was used. Detection wavelengths were set at 270 nm for iso-α-acids and humulinones, 314 nm for α- and β-acids, 280 nm for isoxanthohumol and 370 nm for xanthohumol. Samples were contained in 1.5 mL glass vials compatible with the LC autosampler.

Main Results and Discussion


The method delivered clear resolution of all six analytes with retention times spaced to avoid coelution. Chromatograms at four wavelengths illustrate distinct peak profiles for each compound. The biphenyl stationary phase offered enhanced selectivity for hop phenolics, while multi-wavelength detection allowed quantification without additional derivatization. Method precision exhibited relative standard deviations below 2% for peak area and retention time.

Benefits and Practical Applications


  • Comprehensive profiling of bitter components in a single run.
  • High throughput and reproducibility suitable for QC labs.
  • Applicability to research on functional health benefits of hop-derived compounds.
  • Minimal sample preparation and reagent cost.

Future Trends and Potential Applications


Integration of this LC method with high-resolution mass spectrometry could enhance structural characterization of novel hop derivatives. Adoption of ultra-high-pressure LC and shorter columns promises further throughput gains. Applications may expand to other beverages, dietary supplements and process monitoring in craft and industrial breweries.

Conclusion


A fast, reliable and selective reversed-phase LC method using Shim-pack Velox Biphenyl column enables simultaneous quantification of key bitter and bioactive components in beer. The protocol supports quality control, flavor research and nutritional studies, demonstrating excellent precision and practical utility.

Reference


  • Shimadzu Corporation. Application News an_01-00537 (JP, EN), First Edition: September 2023.

Content was automatically generated from an orignal PDF document using AI and may contain inaccuracies.

Downloadable PDF for viewing
 

Similar PDF

Simultaneous Analysis of Beer Components (Xanthohumol, Humulinones, Iso-α-Acids, α-Acids, and β-Acids) Using an Integrated HPLC System
Analytical Solutions for Food Development
Analytical Solutions for Food Development
2025|Shimadzu|Brochures and specifications
High Speed Analysis of Xanthohumolin Beer
Simultaneous Analysis of Beer Components (Xanthohumol, Isoxanthohumol, Humulinones, Iso-α-Acids, α-Acids, and β-Acids)