Sensitive determination of vitamin B6 in blood samples via fluorescence detection

Applications |  | KNAUERInstrumentation
HPLC, LC columns, Consumables, Sample Preparation
Industries
Pharma & Biopharma
Manufacturer
KNAUER

Significance of the Topic


The precise determination of vitamin B6 in blood is essential for assessing nutritional status and diagnosing metabolic disorders. Plasma pyridoxal 5′-phosphate levels correlate with tissue concentrations and lower nanomolar detection limits are often required for clinical studies.

Objectives and Study Overview


This study demonstrates a rapid UHPLC method integrating bisulfite derivatization within the mobile phase and fluorescence detection to quantify vitamin B6 in blood samples in under five minutes without postcolumn derivatization.

Methodology and Instrumentation


Sample preparation involved deproteinization of EDTA blood, centrifugation, and filtration; pure and spiked samples were analyzed alongside calibration standards (26–260 nmol per liter). The separation used a ProntoSIL 120-5 C18 AQ column (125 × 3 mm, 5 µm) with mobile phase A composed of phosphate buffer, perchlorate, and bisulfite in water/acetonitrile (97:3 v:v) and acetonitrile as mobile phase B. A linear gradient was applied at 1.2 milliliters per minute and detection was performed by fluorescence (excitation 290 nm, emission 400 nm).

Main Results and Discussion


The method achieved baseline separation of vitamin B6 with no postcolumn derivatization pump. Repeatability over five injections yielded relative standard deviations below 1 percent for retention time and peak area. Calibration curves were linear (r2 > 0.999) over 26 to 260 nanomolar, with a limit of detection of 1 nanomolar and quantification at 3 nanomolar. A brief washing step removed matrix components following analyte elution.

Benefits and Practical Applications


The approach offers rapid analysis, low detection limits, high robustness, and simplified workflows suitable for routine clinical laboratories and hospitals.

Future Trends and Applications


Further speed enhancements can be realized using shorter columns, smaller particle sizes, or miniaturized flow systems. Integration with automated platforms and expansion to related vitamers could broaden clinical and research applications.

Conclusion


The presented UHPLC-fluorescence method provides a fast, sensitive, and reliable tool for vitamin B6 analysis in blood, eliminating the need for separate derivatization and meeting clinical throughput demands.

References


1. Leklem JE Handbook of vitamins Marcel Dekker 1991 341-92
2. Edwards P Clinical Chemistry 1989 35(2) 241-245
3. Talwar D Clinical Chemistry 2003 49(3) 515-518
4. Sanson ED Dissertation Lübeck 2008
5. Kimura M Journal of Chromatography A 1996 722 295-301

Content was automatically generated from an orignal PDF document using AI and may contain inaccuracies.

Downloadable PDF for viewing
 

Similar PDF

Determination of 17 AQC derivatized Amino acids in baby food samples
Determination of biocompatible Polymer building Monomers
Determination of Vitamin B6 in Blood Samples with Fluorescence Detection after Derivatization with Bisulfite
Separation of clindamycin phosphate and process impurities