Consumables, LC columns, HPLC, Sample Preparation
IndustriesFood & Agriculture
ManufacturerKNAUER
Significance of the Topic
Solid phase extraction of plant-derived sweeteners like steviol glycosides is critical for ensuring accurate and reliable analysis in food and quality control laboratories.
The development of fast, automated online SPE coupled with HPLC reduces sample preparation time and minimizes analyte loss.
Objectives and Study Overview
This study aims to integrate online SPE with HPLC to streamline purification and quantification of stevioside and rebaudioside A from Stevia leaf extracts.
It evaluates method performance in terms of speed, recovery, repeatability and cartridge lifetime.
Methodology and Instrumentation
- Sample extraction 0.8 g dried stevia leaves in acetonitrile water 70 30, sonication and heating at 70 C for 15 minutes, followed by filtration through a 0.45 µm filter.
- Online SPE cleanup transfer of sample into SteviaClean cartridge, wash with acetonitrile water 90 10 at 2 ml min for 2 minutes.
- HPLC analysis switching cartridge into flow path, elution of analytes using Eurospher NH2 column with acetonitrile water 80 20, flow rate 1 ml min, column temperature 35 C, UV detection at 210 nm.
- Cartridge regeneration sequential flushing with water and acetonitrile water mixtures.
Main Results and Discussion
The combined SPE HPLC method completes purification and quantification within 13 minutes.
Recovery rates were 107 percent for stevioside and 99 percent for rebaudioside A with relative standard deviations of 0.4 percent and 0.9 percent respectively over ten replicates.
Cartridges retain performance for at least ten injections without matrix breakthrough.
Benefits and Practical Applications
- High throughput capable of analyzing up to 60 samples in approximately 15 hours with automated valve switching.
- Reduced solvent consumption and hands on time compared to offline SPE procedures.
- Improved method robustness and repeatability for process monitoring and quality control in the food industry.
Used Instrumentation
- KNAUER PLATINblue HPLC Plus system with dual pumps P1, autosampler AS1, column thermostat T1 with two six to one port valves, PDA detector and assistant module.
- SteviaClean SPE cartridges.
Future Trends and Potential Applications
The online SPE HPLC concept can be extended to other plant matrices and low concentration analytes in pharmaceutical and nutraceutical sectors.
Advancements in dual detection and mass spectrometry coupling may further enhance sensitivity and selectivity.
Automation and multiplexed cartridges could support even higher throughput in routine laboratories.
Conclusion
The described online SPE purification coupled with HPLC offers a rapid, reliable and fully automated solution for steviol glycoside analysis.
This approach significantly reduces analysis time and resource consumption while maintaining high accuracy and precision.
References
- [1] Previous standard SPE procedures for steviol glycoside analysis.
- [2] Developed HILIC HPLC separation method referenced in original study.
Content was automatically generated from an orignal PDF document using AI and may contain inaccuracies.