Driving productivity through reliable analysis with reduced complexity

Others | 2025 | Thermo Fisher ScientificInstrumentation
ICP/MS
Industries
Environmental
Manufacturer
Thermo Fisher Scientific

Importance of the topic


Environmental monitoring of soils and waters for heavy metals is critical to ensure compliance with regulations and to protect public health and ecosystems. High throughput analytical laboratories face the challenge of delivering accurate and reliable results within tight timelines and budgets.

Objectives and study overview


This case study evaluates the implementation of the iCAP MSX ICP MS combined with Qtegra Intelligent Scientific Data Solution software in an ISO 17025 accredited environmental testing laboratory in Edmonton Alberta. The primary aim is to assess improvements in sample throughput instrument stability maintenance requirements and data management over a four month period involving thousands of soil and water samples.

Methodology and instrumentation


Acid digested soil samples and a variety of water matrices including ground lake and surface waters were analyzed for trace metals using the following instrumentation
  • Thermo Scientific iCAP MSX ICP MS
  • easyAGD argon gas dilution module for online aerosol dilution
  • Qtegra Intelligent Scientific Data Solution software featuring Dashboard Get Ready Hawk Consumables and Maintenance Assistant and Instrument Performance Monitoring

Samples were pre diluted offline to maintain total dissolved solids within instrument tolerance. The laboratory processed over 4000 samples in four months with daily system suitability checks.

Main results and discussion


The iCAP MSX ICP MS delivered significant performance benefits including
  • Extended dynamic range reducing the need for offline dilutions
  • Improved matrix tolerance and long term stability via easyAGD
  • Minimal maintenance with no cone or nebulizer cleaning required over 4000 analyses
  • Consistent compliance with performance specifications across 37 operating days
  • Enhanced consumable lifetime and user friendly hardware design improvements
  • Streamlined workflows and reduced training time through software automation


Benefits and practical applications of the method


The combined hardware and software solution enabled
  • High throughput capability supporting over 40 000 soil and 15 000 water analyses annually
  • Reduced downtime and lower operating costs through proactive monitoring and maintenance alerts
  • Delivery of reliable regulatory compliant data for environmental industrial and municipal clients
  • Rapid onboarding of new analysts facilitated by intuitive software features

Future trends and potential applications


Ongoing developments are expected to focus on
  • Further automation of sample preparation and dilution processes
  • Integration of cloud based instrument monitoring and advanced data analytics
  • Development of matrix specific calibrations and coupling with chromatographic techniques
  • Expansion into challenging matrices such as sludge sediments and food safety testing

Conclusion


The deployment of the iCAP MSX ICP MS and Qtegra software in a high throughput environmental laboratory significantly enhanced productivity analytical stability and maintenance efficiency. These advancements support timely reliable trace metal analysis across a broad spectrum of applications.

Reference


  • Thermo Fisher Scientific Case study 003220 Driving productivity through reliable analysis with reduced complexity 2025

Content was automatically generated from an orignal PDF document using AI and may contain inaccuracies.

Downloadable PDF for viewing
 

Similar PDF

Reliable and productive analysis of food samples using single quadrupole ICP-MS
Thermo Scientific iCAP MSX single quadrupole ICP-MS
Thermo Scientific iCAP MSX single quadrupole ICP-MS
2024|Thermo Fisher Scientific|Brochures and specifications
Comprehensive analysis of water samples in alignment with EN ISO Method 17294 using ICP-MS
Multielement analysis of drinking water samples as per regulations from the Bureau of Indian Standards using ICP-MS