LC/MS, LC/HRMS, LC/TOF
IndustriesFood & Agriculture
ManufacturerWaters
Importance of the Topic
The rapid growth of electronic nicotine delivery systems (ENDS) has raised concerns about the chemical composition and safety of ‘e-liquids.’ Routine screening for both known and unknown constituents is essential to ensure product quality, detect potentially harmful species such as carbonyl-containing compounds, and support regulatory and research demands in analytical and industrial laboratories.
Objectives and Study Overview
This application note demonstrates a combined targeted and untargeted screening workflow for a nicotine-free, strawberry-flavored e-liquid using the high-resolution ACQUITY RDa Mass Detector coupled to UPLC. A commercially available extractables and leachables (E&L) library within UNIFI software was employed to identify major components, while unknown peaks were annotated using the UNIFI Elucidation Toolset and online chemical databases.
Methodology and Instrumentation
- Sample Preparation: Dilution of 0.5% w/v in 98:2 mobile phase (A:B).
- UPLC System: ACQUITY UPLC I-Class Premier, Premier BEH C18 column (100×2.1 mm, 1.7 µm), 70 °C column, 10 °C sample temperature, 5 µL injection, 0.4 mL/min flow.
- Mobile Phases: A = 2 mM ammonium formate/0.1% formic acid; B = methanol/0.1% formic acid; gradient 2→99% B over 8.5 min.
- Mass Detection: ACQUITY RDa, full-scan MS with fragmentation (60–150 V ramp) in positive (1.0 kV capillary) and negative (0.8 kV) electrospray, 50–2000 m/z range, 500 °C desolvation.
- Data Processing: UNIFI 3.6 with waters_connect 4.1; E&L library screening and Elucidation Toolset for unknowns.
Key Results and Discussion
System suitability with E&L standard showed mass errors <±3.4 ppm (positive) and <±3.7 ppm (negative). Optimized column temperature (70 °C) and a 95:5 MeOH:acetone needle wash minimized carryover of antioxidant Irganox 245. In positive mode, 33 components were confidently identified (19 containing carbonyl groups), including cinnamaldehyde. Negative mode yielded five more compounds. A prominent unknown at 227.1643 m/z was elucidated as Hedione (C₁₃H₂₂O₃) by isotopic fitting and online library matching.
Benefits and Practical Applications
- Routine sub-5 ppm mass accuracy screening without specialist HRMS expertise.
- Simultaneous high/low energy acquisition for confident fragment-based ID.
- Automated UNIFI workflows for acquisition, processing, and reporting.
- In-built and online libraries enable rapid targeted and untargeted analysis.
Future Trends and Potential Applications
Integration of AI-driven spectral interpretation and expanded spectral libraries will accelerate unknown identification. Coupling RDa screening with quantitative methods for carbonyl compounds could support regulatory monitoring. Portable high-resolution MS platforms may enable on-site quality control for e-liquid manufacturing.
Conclusion
The ACQUITY RDa system combined with UNIFI software offers a robust, user-friendly solution for comprehensive targeted and untargeted screening of e-liquids. High mass accuracy, fragmentation data, and elucidation tools ensure reliable identification of known additives and unknown contaminants, addressing safety and quality concerns in ENDS products.
References
- McDermott MS et al. Addiction. 2021;116(10):2825–2836.
- Mishra A et al. Indian J Pediatr Oncol. 2015;36(1):24–31.
- Gholap VV et al. J Anal Methods Chem. 2018;2018:1720375.
- Schober W et al. Int J Hyg Environ Health. 2013;217:628–637.
- Famele M et al. Nicotine Tob Res. 2015;17(3):271–279.
- Bekki K et al. Int J Environ Res Public Health. 2014;11(11):11192–11200.
- Menicagli R et al. Int J Prev Med. 2020;11:53.
- Waters Corp. Review of BEH Technology.
- Nistoriak MA et al. Toxicol In Vitro. 2019;61:104648.
- PubChem. https://pubchem.ncbi.nlm.nih.gov.
- ChemSpider. https://www.chemspider.com.
Content was automatically generated from an orignal PDF document using AI and may contain inaccuracies.