LC/MS, LC/MS/MS, LC/HRMS, LC/QQQ, LC/TOF
IndustriesFood & Agriculture
ManufacturerShimadzu
Importance of the Topic
Multi-residue pesticide screening in food matrices is critical for consumer safety and regulatory compliance. High-resolution quantitative methods enable detection of trace-level contaminants across diverse commodities, supporting public health and meeting stringent maximum residue limits (MRLs) set by global agencies.
Objectives and Study Overview
This work aimed to develop and validate a high-resolution multiple reaction monitoring (MRM) LC–MS/MS method on a QTOF platform for over 300 pesticides. The method was benchmarked against a data-independent acquisition (DIA) approach, with performance assessed in apple, honey, olive oil, orange and tomato matrices at target concentration levels as low as 0.1 µg/kg.
Methodology and Instrumentation
Sample Preparation and Extraction:
- 317 pesticides plus 10 deuterated internal standards spiked into five food matrices (0.1–100 µg/kg).
- Standard QuEChERS extraction followed by cleanup steps.
Chromatography and Mass Spectrometry:
- Reverse-phase LC on Shim-pack Velox Biphenyl column (100 × 2.1 mm, 2.7 µm) at 45 °C.
- Shimadzu LCMS-9050 QTOF operated in positive ESI mode; external mass calibration with continuous calibrant infusion.
- High-resolution scanning MRM: targeted TOF MS scan (m/z 110–950) plus MS/MS scans with optimized collision energies transferred from a triple quadrupole library.
- DIA-MS/MS comparison: wider precursor isolation windows (20–35 Da) and collision energy ramps.
Main Results and Discussion
Signal Intensity and Sensitivity:
- High-resolution MRM yielded reference ion signals up to threefold greater than DIA, enabling limits of quantitation below 1 µg/kg.
- Narrow isolation windows (0.8 Da) and specific collision energies enhanced selectivity for co-eluting analytes.
Repeatability and Regulatory Compliance:
- %RSD ≤ 20% (n = 6) for 312 out of 317 targets at the 10 µg/kg MRL in tomato matrix.
- All analytes met EU SANTE 11312/2021 v2 reporting criteria for quantitation and mass accuracy.
Comparison with DIA:
- DIA provided broader coverage but at the expense of sensitivity and selectivity.
- High-resolution MRM demonstrated lower mass error (< 5 ppm) and improved peak area ratios for key pesticides.
Benefits and Practical Applications
This targeted high-resolution MRM approach offers:
- Enhanced detection capability for regulatory monitoring and food safety laboratories.
- Versatility across complex matrices including high-fat and high-sugar commodities.
- Streamlined adoption by labs already using triple quadrupole methods due to matched collision energies.
Future Trends and Potential Applications
Emerging opportunities include:
- Integration of automated data processing and AI-driven method optimization.
- Expansion of high-resolution MRM libraries to cover novel or emerging contaminants.
- Coupling with ion mobility separation for additional selectivity in complex matrices.
- Application to other commodity types and environmental samples.
Conclusion
The high-resolution scanning MRM method on a QTOF platform delivers superior sensitivity and selectivity for multi-residue pesticide quantitation compared to DIA-MS/MS. It meets EU SANTE guidelines, exhibits robust repeatability, and supports lower limits of quantification, making it a powerful tool for routine food safety analysis.