Importance of the Topic


Multi-residue pesticide screening in food matrices is critical for consumer safety and regulatory compliance. High-resolution quantitative methods enable detection of trace-level contaminants across diverse commodities, supporting public health and meeting stringent maximum residue limits (MRLs) set by global agencies.

Objectives and Study Overview


This work aimed to develop and validate a high-resolution multiple reaction monitoring (MRM) LC–MS/MS method on a QTOF platform for over 300 pesticides. The method was benchmarked against a data-independent acquisition (DIA) approach, with performance assessed in apple, honey, olive oil, orange and tomato matrices at target concentration levels as low as 0.1 µg/kg.

Methodology and Instrumentation


Sample Preparation and Extraction:
  • 317 pesticides plus 10 deuterated internal standards spiked into five food matrices (0.1–100 µg/kg).
  • Standard QuEChERS extraction followed by cleanup steps.

Chromatography and Mass Spectrometry:
  • Reverse-phase LC on Shim-pack Velox Biphenyl column (100 × 2.1 mm, 2.7 µm) at 45 °C.
  • Shimadzu LCMS-9050 QTOF operated in positive ESI mode; external mass calibration with continuous calibrant infusion.
  • High-resolution scanning MRM: targeted TOF MS scan (m/z 110–950) plus MS/MS scans with optimized collision energies transferred from a triple quadrupole library.
  • DIA-MS/MS comparison: wider precursor isolation windows (20–35 Da) and collision energy ramps.

Main Results and Discussion


Signal Intensity and Sensitivity:
  • High-resolution MRM yielded reference ion signals up to threefold greater than DIA, enabling limits of quantitation below 1 µg/kg.
  • Narrow isolation windows (0.8 Da) and specific collision energies enhanced selectivity for co-eluting analytes.

Repeatability and Regulatory Compliance:
  • %RSD ≤ 20% (n = 6) for 312 out of 317 targets at the 10 µg/kg MRL in tomato matrix.
  • All analytes met EU SANTE 11312/2021 v2 reporting criteria for quantitation and mass accuracy.

Comparison with DIA:
  • DIA provided broader coverage but at the expense of sensitivity and selectivity.
  • High-resolution MRM demonstrated lower mass error (< 5 ppm) and improved peak area ratios for key pesticides.

Benefits and Practical Applications


This targeted high-resolution MRM approach offers:
  1. Enhanced detection capability for regulatory monitoring and food safety laboratories.
  2. Versatility across complex matrices including high-fat and high-sugar commodities.
  3. Streamlined adoption by labs already using triple quadrupole methods due to matched collision energies.

Future Trends and Potential Applications


Emerging opportunities include:
  • Integration of automated data processing and AI-driven method optimization.
  • Expansion of high-resolution MRM libraries to cover novel or emerging contaminants.
  • Coupling with ion mobility separation for additional selectivity in complex matrices.
  • Application to other commodity types and environmental samples.

Conclusion


The high-resolution scanning MRM method on a QTOF platform delivers superior sensitivity and selectivity for multi-residue pesticide quantitation compared to DIA-MS/MS. It meets EU SANTE guidelines, exhibits robust repeatability, and supports lower limits of quantification, making it a powerful tool for routine food safety analysis.

References


  • European Commission. SANTE/11312/2021 v2 – Guidance on analytical quality control and method validation for pesticide residues in food and feed.

Content was automatically generated from an orignal PDF document using AI and may contain inaccuracies.

Downloadable PDF for viewing
 

Similar PDF

Development of a high-resolution MRM quantitative method for pesticides in apple, honey, olive oil, orange and tomato food matrices
Targeted quantitative screening pesticides in food matrices using high resolution DIA spectral library matching
QuEChERS extracted pesticide quantitation by LCMS QTOF using HRAM at high data acquisition speed
Accelerating large scale pesticide screening programs with HR LC–MS/MS using automated non-targeted analysis software