Thermo Scientific iCAP RQ ICP-MS with iMR

Brochures and specifications | 2017 | Thermo Fisher ScientificInstrumentation
ICP/MS
Industries
Manufacturer
Thermo Fisher Scientific

Significance of the Topic



Inductively coupled plasma mass spectrometry (ICP-MS) is widely recognized for its sensitivity, dynamic range and versatility in trace elemental analysis. Routine laboratories in environmental monitoring, pharmaceuticals, food safety, materials science and research require instruments that combine robustness, ease of use and advanced interference removal to maintain high throughput and data quality.

Study Objectives and Overview



The Thermo Scientific iCAP RQ ICP-MS with intelligent Mass Resolution (iMR) and QCell collision/reaction cell (CRC) was developed to address the needs of demanding 24/7 operations and advanced research applications. This whitepaper presents an overview of its design features, performance specifications and workflow integration aspects aimed at simplifying method development, maximizing uptime and ensuring reliable quantification across a broad range of sample matrices.

Methodology and Instrumentation



Sample Introduction and Plasma
  • Bench-height, low-volume cyclonic spraychamber with Peltier cooling for rapid washout.
  • Concentric quartz nebulizer (0.4 mL/min) compatible with organics and high-TDS samples; optional flow rates.
  • Push-in, demountable quartz torch with integrated gas and ignition connections.
  • Digital solid-state RF generator (27 MHz) with dynamic impedance matching and water-cooled load coil.

Interface and Ion Optics
  • Front-opening interface housing nickel sample cone (1.1 mm) and skimmer cone (0.5 mm); Pt-tipped options.
  • Single low-voltage extraction lens and unique RAPID 90° cylindrical ion lens for high ion transmission and low background.
  • QCell CRC with flatapole design for He KED mode and optional reactive gases (H₂, O₂, NH₃/He) supporting single-mode interference removal.

Mass Analyzer and Detection
  • Quadrupole driven by a 2 MHz supply, mass range 2–290 u, user-definable resolution.
  • Detector offering simultaneous pulse and analog detection over >10 orders of magnitude and automated voltage optimization.

Vacuum and Software
  • Split-flow turbo pump with external rotary backing; rapid pump-down < 15 min and automatic restart after power loss.
  • Qtegra ISDS Software for full workflow control from instrument setup to reporting, including Title 21 CFR Part 11 compliance, plug-in support for autosamplers, laser ablation, speciation, nanoparticle analysis and autodilution.

Key Results and Discussion



The iCAP RQ ICP-MS delivers:
  • Sensitivity up to 330 kcps/ppb (e.g. U 238) and detection limits < 0.1 ppt for selected elements.
  • Oxide ratios < 2 % CeO/Ce and doubly charged ion formation < 3 % Ba²⁺/Ba⁺.
  • Short-term stability < 2 % RSD (10 min) and long-term < 3 % RSD (2 h).
  • Effective interference removal in He KED mode across the entire mass range, with additional low mass cut-off for reactive modes.

These results demonstrate exceptional robustness even with complex matrices and organic solvents, while minimizing maintenance and downtime.

Benefits and Practical Applications



The iCAP RQ ICP-MS streamlines routine and advanced analyses by offering:
  • User-friendly operation and simplified method development with automated interference removal.
  • Fully integrated sample handling and optional gas dilution to extend plasma tolerance.
  • Modular software architecture supporting a wide range of peripherals and compliance requirements.
  • High productivity through rapid maintenance access, stable vacuum and remote plasma monitoring.

Typical applications include environmental water testing, pharmaceutical QC, food safety screening, geochemical exploration, speciation, nanoparticle characterization and laser ablation mapping.

Future Trends and Potential Uses



Emerging directions for ICP-MS instrumentation include integration of AI-driven diagnostics, expanded use of reactive gas chemistries for challenging interferences, real-time data processing pipelines, and tighter coupling with separation techniques. Miniaturized and automated platforms will further enhance remote or field-deployable elemental analysis.

Conclusion



The Thermo Scientific iCAP RQ ICP-MS with iMR and QCell technology represents a comprehensive solution for high-throughput, routine and advanced elemental analysis. Its combination of robust hardware, versatile interference management, rapid maintenance design and powerful software underscores its suitability for diverse laboratory environments seeking reliable, accurate and efficient ICP-MS workflows.

References



No formal literature references were provided in the original text.

Content was automatically generated from an orignal PDF document using AI and may contain inaccuracies.

Downloadable PDF for viewing
 

Similar PDF

Thermo Scientific iCAP TQ ICP-MS (PRODUCT SPECIFICATION)
Thermo Scientific iCAP TQ ICP-MS (PRODUCT SPECIFICATION)
2020|Thermo Fisher Scientific|Brochures and specifications
Thermo Scientific iCAP TQs ICP-MS (PRODUCT SPECIFICATION )
Thermo Scientific iCAP TQs ICP-MS (PRODUCT SPECIFICATION )
2020|Thermo Fisher Scientific|Brochures and specifications
Thermo Scientific iCAP MSX ICP-MS (Product specifications)
Thermo Scientific iCAP MSX ICP-MS (Product specifications)
2025|Thermo Fisher Scientific|Brochures and specifications
Thermo Scientific iCAP RQ ICP-MS
Thermo Scientific iCAP RQ ICP-MS
2017|Thermo Fisher Scientific|Brochures and specifications