LC/MS, LC/MS/MS, LC/QQQ
IndustriesPharma & Biopharma
ManufacturerShimadzu
Importance of the topic
Nitrosamine impurities are recognized carcinogens found in various drugs, including anti-diabetic medications. Regulatory agencies impose strict limits to protect patients. Developing reliable analytical methods for trace-level detection is crucial for pharmaceutical quality control and regulatory compliance.
Objectives and Study Overview
The study aims to establish a straightforward, sensitive LC-MS/MS method using atmospheric-pressure chemical ionization (APCI) for simultaneous quantification of ten nitrosamines, including nitroso-sitagliptin as an NDSRI, in anti-diabetic drug products. Method validation and real-sample analysis demonstrate the method’s applicability.
Methodology
- Calibration standards were prepared by serial dilution of concentrated nitrosamine stocks in LCMS-grade methanol to cover 0.1–10 ng/mL (API equivalent to 1–100 ppb).
- Drug samples (100 mg API equivalent) were extracted with 1 mL ultrapure water, sonicated, centrifuged, and filtered (0.22 µm) prior to analysis.
- Detection was carried out on Shimadzu LCMS-8060NX operating in MRM mode with APCI for enhanced sensitivity.
Instrumentation Used
- Shimadzu LCMS-8060NX triple quadrupole mass spectrometer
- Atmospheric-pressure chemical ionization (APCI) source
- Analytical HPLC system with optimized chromatographic column for nitrosamine separation
Key Results and Discussion
- Calibration curves for ten nitrosamines exhibited excellent linearity (R2 > 0.999) over 0.1–10 ng/mL.
- Limits of quantitation were below 10% of regulatory thresholds.
- Accuracy fell within ±20% and precision (RSD) remained <10% at LOQs (n=6).
- Recovery studies at LOQs in two drug matrices showed satisfactory recoveries.
- Application to commercial anti-diabetic samples revealed detectable levels of certain nitrosamines, highlighting practical relevance.
Benefits and Practical Applications of the Method
- Simplified sample preparation with minimal solvent and a 10 µL injection volume
- High sensitivity reaching 0.1 ng/mL quantitation, suitable for strict regulatory limits
- Adaptable chromatographic conditions permit extension to various drug products
- Supports routine pharmaceutical safety testing and quality assurance
Future Trends and Potential Applications
- Broader screening panels covering additional nitrosamines and related impurities
- Integration with high-throughput, automated sample processing workflows
- Real-time in-process monitoring during drug manufacturing
- Use in risk assessment, process optimization, and regulatory submission support
Conclusion
The developed APCI-based LC-MS/MS method on Shimadzu LCMS-8060NX provides a robust, sensitive, and efficient solution for quantifying nitrosamine impurities at trace levels in anti-diabetic drugs, ensuring compliance with regulatory standards and safeguarding patient health.
Reference
- Nitrosamines as Impurities in Drugs – Health Risk Assessment and Mitigation Public Workshop, Food and Drug Administration, 2021.
- Nitrosamine impurities, European Medicines Agency, accessed 2024-02-01.
- Control of Nitrosamine Impurities in Human Drugs, U.S. Food and Drug Administration, 2020.
- Nitrosamine impurities in medicines, Health Sciences Authority, accessed 2024-02-01.
Content was automatically generated from an orignal PDF document using AI and may contain inaccuracies.