LC/HRMS, LC/MS, LC/MS/MS, LC/TOF, Ion Mobility
IndustriesOther
ManufacturerAgilent Technologies
Significance of the Topic
Adding ion mobility to LC-MS experiments introduces an orthogonal separation dimension that enhances the analysis of complex mixtures. By converting LC-IM-MS data into formats compatible with established LC-MS workflows, researchers can leverage existing informatics tools to extract deeper insights from lipidomics, PFAS profiling, and other applications.
Objectives and Study Overview
- Enable traditional LC-MS data analysis workflows to process LC-IM-MS files through novel data conversions.
- Integrate mapping of ion mobility (IM) axis to chromatographic axis and conversion of All Ions IM/MS fragmentation into data-dependent acquisition (DDA) spectra.
- Evaluate an automated high-resolution demultiplexing (HRdm) workflow for improved spectral clarity.
- Explore conversion of comprehensive 2D-LC MS data into LC-IM-MS format for four-dimensional analysis.
Methodology and Instrumentation
- Instrumentation: Agilent 6560 IM-QTOF coupled to 1290 Infinity II LC for both 1D and 2D separations.
- Samples: NIST SRM 1950 human plasma lipid extract and ITA-70 PFAS standard.
- Software Tools: PNNL PreProcessor for data conversion, IM-MS Browser for ion mobility feature extraction, MassHunter Qual, Lipid Annotator, Mass Profile, and MS-DIAL for downstream analysis.
- Conversion Workflows: Two PNNL PreProcessor modes – Workflow 1 maintains chromatographic elution, Workflow 2 treats drift time as retention time in output DDA files.
Main Results and Discussion
- All Ions IM/MS-to-DDA Conversion:
• Converted files yielded the highest number of lipid identifications by capitalizing on the improved duty cycle of All Ions acquisition.
• Mirror‐plot comparisons showed expectedly lower dot‐product similarity versus quadrupole isolation but better fragment coverage for smaller lipid fragments. - Isomer Treatment:
• Workflow 1 generated separate spectra per isomer when stepped collision energy was applied, but overlapping fragments could complicate interpretation.
• Workflow 2 fully resolved IM isomers into distinct DDA events, yielding two unique spectra for LPC 20:3 in downstream analysis (MassHunter Qual and MS-DIAL). - High-Resolution Demultiplexing (HRdm):
• The new HRdm 3.0 workflow integrates interpolation, demultiplexing, feature finding, and deconvolution in a single automated step.
• This reduces user handling of multiple software packages and streamlines the conversion to DDA format. - Single Pulse vs Multiplexed Acquisition:
• Multiplexed All Ions data processed with automated HRdm increased lipid IDs in both Lipid Annotator and MS-DIAL compared to single pulse.
• Triacylglycerol lipids, which often have broader fragment bands, benefited from HRdm deconvolution. - 2D-LC MS to LC-IM-MS Conversion:
• Conversion of PFAS standard set via PNNL PreProcessor allowed four-dimensional feature extraction, detecting 12 of 14 standards in both native LC-IM-MS and converted datasets.
• Ongoing work focuses on assessing mass accuracy and applying IM peak detection to chromatographic peak shapes.
Benefits and Practical Applications
- Maximized lipid and small molecule identifications through improved duty cycles and deconvolution.
- Ability to resolve and analyze IM isomers as separate spectral events.
- Streamlined workflow reduces software dependencies and simplifies data conversion.
- Compatibility with existing LC-MS tools extends capabilities to four-dimensional datasets in lipidomics, environmental analysis, and QA/QC.
Future Trends and Applications
- Expansion of PNNL PreProcessor capabilities for seamless conversion of comprehensive 2D-LC datasets into LC-IM-MS format.
- Integration of enhanced mass calibration and alignment routines for improved accuracy in converted files.
- Advanced feature detection algorithms to exploit four-dimensional separation for novel biomarker discovery.
- Potential for automated workflows combining IM conversion, HRdm, and downstream identification in a single pipeline.
Conclusion
Data file conversions provided by the PNNL PreProcessor enable existing LC-MS workflows to harness the full potential of ion mobility separations. Automated high-resolution demultiplexing and IM-to-DDA transformations yield richer spectral data, increase identification rates, and simplify processing. Converting 2D-LC MS to LC-IM-MS formats further broadens analytical capability, paving the way for comprehensive four-dimensional studies.
References
- Bilbao A., Mejía E., et al. Journal of Proteome Research 2022;21(3):798-807.
- Tsugawa H., Cajka T., et al. Nature Methods 2015;12(6):523-526.
- Wright J., et al. Agilent Technologies Technical Overview 2022.
Content was automatically generated from an orignal PDF document using AI and may contain inaccuracies.