LC/MS, LC/MS/MS, LC/QQQ, Consumables, LC columns
IndustriesMetabolomics
ManufacturerShimadzu
Significance of the Topic
Biological metabolomics enables comprehensive profiling of small-molecule metabolites to understand physiological states, disease mechanisms, and biotechnological processes.
Objectives and Study Overview
This application demonstrates a unified LC/MS method for simultaneous analysis of 49 hydrophilic metabolites—including amino acids, nucleobases, nucleosides, nucleotides, coenzymes, and organic acids—using the Shim-pack Mix-HILIC column coupled to the LCMS-8060NX.
Methodology and Used Instrumentation
- UHPLC System: Nexera X3
- Mass Spectrometer: LCMS-8060NX triple quadrupole with ESI IonFocus source in MRM mode
- Chromatographic Column: Shim-pack Mix-HILIC (150 mm × 2.1 mm I.D., 5 µm) featuring amine and quaternary ammonium groups on a crosslinked polymethacrylate matrix (pH range 2–13, up to 35 MPa).
- Mobile Phases: A = 40 mM ammonium bicarbonate, pH 9.7 in water; B = acetonitrile. Gradient: 95% B (0–0.5 min) → 40% B (15.5 min) → 0% B (16.5–26.5 min) → 95% B (27.5–35 min), flow rate 0.4 mL/min, column oven 40 °C, injection 5 µL.
- MS Conditions: Nebulizing gas 2.0 L/min, drying gas 10.0 L/min, heating gas 10.0 L/min, DL temp. 250 °C, heat block 400 °C, interface temp. 300 °C, CID gas 270 kPa.
- Sample Preparation: E. coli cells and human plasma extracted by methanol/chloroform/water biphasic partitioning, centrifugation, concentration, and reconstitution in 1:1 water/methanol.
Main Results and Discussion
- All targeted classes are resolved in a single gradient run: uncharged and cationic metabolites elute before 12.8 min, while anionic metabolites elute thereafter.
- Detection performance: 44 of 49 metabolites in E. coli and 25 in plasma, demonstrating broad applicability across sample types.
Benefits and Practical Applications
- Single-run coverage of diverse polar analytes reduces total analysis time, solvent consumption, and sample requirements.
- Suitable for microbial metabolomics, clinical bioanalysis, QA/QC, and industrial analytics where comprehensive polar profiling is required.
Future Trends and Possibilities
- Integration with automated, high-throughput platforms for large-scale studies.
- Method optimization to extend analyte coverage by adjusting buffer pH and gradient profiles.
- Coupling with high-resolution MS to combine targeted quantitation with untargeted discovery workflows.
Conclusion
The Shim-pack Mix-HILIC column paired with LCMS-8060NX offers a robust, high-throughput solution for comprehensive analysis of hydrophilic metabolites under basic conditions, making it a versatile tool for diverse metabolomic investigations.
Used Instrumentation
- Nexera X3 UHPLC
- LCMS-8060NX triple quadrupole mass spectrometer
- Shim-pack Mix-HILIC column (150 mm × 2.1 mm, 5 µm)
References
No explicit references were provided in the source material.
Content was automatically generated from an orignal PDF document using AI and may contain inaccuracies.