Improved OPA /FMOC Derivatized Amino Acid Methods using Many Column Configurations for a Range of Speed and Resolution Options

Posters | 2009 | Agilent Technologies | HPLC SymposiumInstrumentation
Consumables, HPLC, LC columns
Industries
Food & Agriculture, Clinical Research
Manufacturer
Agilent Technologies

Significance of the Topic


The accurate and efficient analysis of amino acids is critical in fields such as pharmaceutical development, biotechnology, food safety, and clinical diagnostics. Automated pre-column derivatization using OPA and FMOC reagents enables sensitive UV detection of primary and secondary amino groups, respectively, streamlining workflows and improving throughput.

Study Objectives and Overview


This work presents an updated automated OPA/FMOC derivatization method optimized for ten ZORBAX Eclipse Plus C18 column configurations. The aim is to demonstrate scalability from fast nine-minute analyses to traditional high-resolution separations, maintain reproducibility, and enable seamless method transfer across HPLC platforms.

Methodology and Instrumentation


The automated pre-column derivatization sequence employs:
  • OPA/3-mercaptopropionic acid at pH 10 for primary amines, monitored at 338 nm.
  • FMOC at pH 10 for secondary amines, monitored at 262 nm.
  • Agilent 1100/1200 SL series pumps, G1329A or G1367 series autosamplers, heat exchanger, and DAD detectors.
  • Ten column options: particle sizes 5.0, 3.5, and 1.8 µm; lengths 50–250 mm; internal diameters 2.1, 3.0, and 4.6 mm.
  • Binary and quaternary mixing capabilities to suit different system types.

Results and Discussion


All column configurations share an identical gradient profile, with gradient delay effects mitigated by initial isocratic holds. Key findings include:
  • Injection-to-injection reproducibility for early, middle, and late-eluting amino acids showed mean relative standard deviations below 5 %.
  • Resolution (Rs) values above 2.0 were achieved even in rapid 9-minute methods using 1.8 µm columns.
  • Linearity for representative amino acids (e.g., glutamate, lysine, proline) was confirmed from 1 to 1000 pmol/µL (R² > 0.997).
  • Lot-to-lot reproducibility demonstrated consistent selectivity (α ratios) across three production batches.

Benefits and Practical Applications


The updated protocol provides:
  • Flexible method options balancing speed, resolution, and solvent consumption.
  • Seamless transfer between LC systems (binary/quaternary pumps; 400 bar to 600 bar).
  • Robust performance evidenced by method ruggedness and equipment longevity.

Future Trends and Potential Applications


Emerging directions include:
  • Integration with ultra-high-pressure LC (UHPLC) for sub-two-minute analyses.
  • New stationary phases with enhanced selectivity for challenging amino acids.
  • Further miniaturization for microflow and nanoflow LC-MS coupling.
  • Advanced automation workflows and multiplexed derivatization for high-throughput screening.

Conclusion


The enhanced automated OPA/FMOC derivatization method, adaptable to ten column formats, delivers high reproducibility, broad dynamic range, and flexible throughput options. It supports diverse laboratory needs and facilitates efficient amino acid analysis in demanding analytical environments.

References


  • R. Schuster and A. Apfel, HP Application Note Pub. #5954-6257 (1986).
  • R. Schuster, J. Chromatogr. 431, 271-284 (1988).
  • H. Godel, P. Seitz, M. Verhoef, LC-GC International 5(2), 44-49 (1992).
  • A. Gratzfeld-Huesgen, Agilent Pub. #5968-5658EN (1999).
  • J. W. Henderson Jr. et al., Agilent Pub. #5980-1193E (2000).
  • C. Woodward et al., Agilent Pub. #5989-6297EN (2007).

Content was automatically generated from an orignal PDF document using AI and may contain inaccuracies.

Downloadable PDF for viewing
 

Similar PDF

Amino Acid Analysis - Application Compendium
Amino Acid Analysis - Application Compendium
2021|Agilent Technologies|Guides
Agilent Approaches for Amino Acid Analysis
Agilent Approaches for Amino Acid Analysis
2020|Agilent Technologies|Presentations
Agilent Biocolumns - Amino Acid Analysis - "How-To" Guide